  1. Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography

    Accurate estimation of the proton stopping power ratio (SPR) is important for treatment planning and dose prediction for proton beam therapy. The state-of-the-art clinical practice for estimating patient-specific SPR distributions is the stoichiometric calibration method using single-energy …

    wustl Repository record for Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography (opens in a new tab)

  2. Advances in dual-energy computed tomography imaging of radiological properties

    … potential in the reduction of uncertainties of proton ranges and low energy photon cross section estimation used in radiation therapy planning. The work presented herein investigated three contributions for advancing DECT applications. 1) A linear and separable two-parameter DECT, the basis …

    vcu Repository record for Advances in dual-energy computed tomography imaging of radiological properties (opens in a new tab)

  3. Effects of Proton Irradiation on the Mechanical and Physical Properties of Carbon Nanotube Based Composites

    In this study, the effects of proton irradiation on carbon nanotube (CNT)-epoxy composites are investigated for potential applications in radiation shielding for spacecraft. CNT-epoxy composites were prepared using multiwall and single wall CNTs and exposed to proton beams of energies ranging from …

    vt Repository record for Effects of Proton Irradiation on the Mechanical and Physical Properties of Carbon Nanotube Based Composites (opens in a new tab)

  4. Proton radiotherapy uncertainties arising from computed tomography

    <p>Proton radiotherapy is a cancer treatment which has the potential to offer greater cure rates and/or fewer serious side effects than conventional radiotherapy. Its availability in the UK is currently limited to a single low-energy fixed beamline for the treatment of ocular tumours, but a number …

    oxford Repository record for Proton radiotherapy uncertainties arising from computed tomography (opens in a new tab)

  5. Alpha-particle generation via laser-driven proton-boron fusion

    The proton-boron-11 (p¹¹B) fusion reaction is an aneutronic process that produces three alpha particles and releases 8.7 MeV of energy entirely through charged particles, making it an attractive alternative to deuterium-tritium fusion for both energy production and as a source of energetic …

    qu-belfast Repository record for Alpha-particle generation via laser-driven proton-boron fusion (opens in a new tab) Embargoed until 2027-07-31

  6. Optimisation studies for a high gradient proton Linac for application in proton imaging : ProBE: Proton Boosting Linac for imaging and therapy

    Proton beam therapy is an alternative to traditional X-ray radiotherapy utilised especially for paediatric malignancies and radio-resistant tumours; it allows a precise tumour irradiation, but is currently limited by knowledge of the patient density and thus the particle range. Typically X-ray …

    lancaster Repository record for Optimisation studies for a high gradient proton Linac for application in proton imaging : ProBE: Proton Boosting Linac for imaging and therapy (opens in a new tab)

  7. Dual Energy Computed to mography For Proton Therapy Treatment Planning

    Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target …

    uthsc Repository record for Dual Energy Computed to mography For Proton Therapy Treatment Planning (opens in a new tab)

  8. Imaging Techniques for Proton Range Determination in Proton Therapy

    Proton therapy can achieve better sparing of normal tissues than the conventional photon radiation therapy due to proton’s Bragg Peak property. However, to unlock the full potential of protons, accurate prediction of in vivo proton stopping power ratio (SPR) is required for proton therapy treatment …

    wustl Repository record for Imaging Techniques for Proton Range Determination in Proton Therapy (opens in a new tab)

  9. Treatment verification in proton therapy based on the detection of prompt gamma-rays

    Background The finite range of a proton beam in tissue and the corresponding steep distal dose gradient near the end of the particle track open new vistas for the delivery of a highly target-conformal dose distribution in radiation therapy. Compared to a classical photon treatment, the potential …

    qucosa-diss Repository record for Treatment verification in proton therapy based on the detection of prompt gamma-rays (opens in a new tab)

  10. Dual-Energy Computed Tomography for Accurate Stopping-Power Prediction in Proton Treatment Planning

    Derzeitige Reichweiteunsicherheiten in der Protonentherapie verhindern das vollständige Ausschöpfen ihrer physikalischen Vorteile. Ein wesentlicher Anteil ist dabei auf die Vorhersage der Reichweite mittels Röntgen-Computertomographie (CT) zurückzuführen. Um die CT-bezogene Unsicherheit zu …

    qucosa-diss Repository record for Dual-Energy Computed Tomography for Accurate Stopping-Power Prediction in Proton Treatment Planning (opens in a new tab)

  11. Evaluation and Clinical Implementation of a Dual-Energy CT Stopping-Power Ratio Mapping Technique for Proton-Therapy Treatment Planning

    Proton radiotherapy has the potential to treat tumors with better conformal dose distribution than competing modalities when the rapid dose falloff at the end of the proton-beam range is correctly aligned to the edge of the clinical target volume (CTV). However, its clinical potential is dependent …

    wustl Repository record for Evaluation and Clinical Implementation of a Dual-Energy CT Stopping-Power Ratio Mapping Technique for Proton-Therapy Treatment Planning (opens in a new tab)