Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 28 for “"proton-recoil"”
-
Deconvoluting an Americium-Beryllium Neutron Spectrum from a Proton Recoil Detector
A proton recoil detector was acquired from LND, Inc. to be used in neutron counting experiments with an 241AmBe source. Neutrons elastically scatter off of and ionize hydrogen atoms creating protons that can be detected. A single neutron can undergo multiple scattering events and this can result in …
-
Design, Construction, and Calibration of a Proton Recoil Proportional Counter for Neutron Spectrum Measurements
Made available in DSpace on 2017-07-06T18:55:22Z (GMT). No. of bitstreams: 2 Mertogul_Remzi_MS.pdf: 40599039 bytes, checksum: e62ff031c4bb21e0db562a5c64ed9490 (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 1979
-
Comparison of neutron fluence spectra measured with NE213 proton recoil spectrometer and NE230 deuteron recoil spectrometer
… target, or a (10 mm) graphite target with 66 MeV proton beam were measured with both spectrometers. Deuteron events identified by pulse shape discrimination were selected for measurements with the NE230 spectrometer while proton events were selected for measurements with the NE213 spectrometer. …
-
Measurement and model prediction of proton-recoil track length distributions in NTA film dosimeters for neutron energy spectroscopy and retrospective dose assessment
… calculations. </p><p>Monte Carlo models of proton-recoil track length distributions were developed and benchmarked against measurement data for both NTA and Ilford films. These models, when applied to several NTA film dosimeter configurations, demonstrated that proton-recoil track length …
-
The Neutron Energy Spectrum from Stopped Negative π Meson Interactions in Nuclear Emulsions
… π mesons. The method of detection is the proton recoil method, and the choice of detector is the nuclear emulsion (G-5 Ilford).
-
A Novel Neutron Recoil Spectrometer Concept Utilizing Heavy-Ion Recoils and Time- and Spatially-Resolved Sensor
This thesis describes a heavy-ion recoil neutron spectrometer as an alternative to existing magnetic proton recoil neutron spectrometers for inertial confinement fusion experiments. Whereas existing designs elastically scatter neutrons o↵ protons or deuterons, which are then magnetically analyzed …
-
The Leakage Neutron Spectrum of a Spherical Critical Assembly of U233
… after development, examining the details of the proton-recoil tracks visible in the emulsion.
-
Use of silicon surface-barrier detectors for neutron detection
… of producing a neutron spectrometer using the proton recoil telescope with the surface-barrier detector. These objects were fulfilled. From the results with the protein recoil telescope, there is a possibility of producing a neutron spectrometer using the proton recoil telescope and …
-
A high energy neutron spectrometer.
A proton recoil spectrometer designed to measure neutron spectra in the energy range of 50 MeV to 100 MeV has been built. An attempt was made to improve the energy resolution of this spectrometer as compared to other spectrometers of a similar type by using a scintillator as the converter in which …
-
A fast neutron spectrometer
… was designed and constructed using a proton-recoil telescope. Recoil protons from a thin foil of polyethylene were detected with a silicon surface-barrier diode. The output pulse from the detector is proportional to the energy of the protons and hence the energy of the incident …
-
First Measurements of Earth Albedo Neutrons in Space
… satellite OSO-6 carried as part of its payload a proton recoil telescope capable of detecting neutrons between 40 and 200 MeV with directional discrimination. Sixteen months of data from this instrument were analyzed with a view to determining properties of the earth albedo neutron flux above the …
-
Measurement of the Average Solar Neutron Flux and its Correlation with Solar Activity
… neutrons from the sun. The detector is a proton recoil telescope capable of directional discrimination and responsive to neutrons of energies between 20 and 200 MeV with an effective average efficiency for this analysis of 10-4 and an effective area of 80cm2. The detector was located in a …
-
Estimating the neutron background toward the measurement of neutrino mixing angle [theta][subscript]1[subscript]3 with the Double Chooz detector
… which give rise to correlated events through proton recoil followed by a neutron capture. Muons stopping around the chimney region subsequently decay into Michel electrons also contributing to the correlated background. Measurement of the shape and rate of this background is very important for …
-
Design and Simulation of a Boron-loaded Neutron Spectrometer
… neutrons to all neutrons. Future work using proton recoil spectral data from individual fibers will allow increases in energy resolution while reducing or eliminating the need for a priori spectral information.
-
The Atmospheric neutron spectrum at high altitudes
… was performed with a directionally sensitive proton recoil detector. The detector consisted of two counters of scintillator plastic which measured dE/dx and energy of proton recoils originating in a third plastic scintillator. Charged particles were eliminated by a guard counter. Energy …
-
Detector Response Simulations of Hydrocarbon Neutron Scintillators
… scintillators. The first is a well studied proton-recoil scintillator (NE-213) and the second is a deuteron-recoil scintillator (EJ-315), similar to that which is used by DESCANT. The detector response to mono-energetic neutrons is then measured for the two scintillators using cylindrical …
-
Measurement of the 235 U(n,f) cross section relative to the neutron-proton elastic scattering up to 500 MeV at n_TOF
… measured by exploiting the neutron-proton scattering process using three Proton Recoil Telescopes. In this PhD thesis the development, implementation and characterisation of the two telescopes under the responsibility of the INFN are discussed, as well as the analysis of the data …
-
Fast Neutron Attenuation and Energy Loss in Extended Shields
… at its centre. All measurements were made with a proton recoil scintillation spectrometer using NE-213 liquid organic scintillator, and gamma ray background was discriminated by pulse shape discrimination using the zero crossing technique. Calibration of the spectrometer energy scale was made with …
Page 1 of 2