Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 55 for “"pull-test"”

  1. Comparisons Between Movement Onset Identification Methods Used in Isometric Mid-Thigh Pull Test

    … for onset detection in the isometric mid-thigh pull test. First, we examined applications of three differential calculus principles, first and second derivative, and curvature using visual detection as a reference under different baseline conditions. Second, we compared the best derivative …

    etsu Repository record for Comparisons Between Movement Onset Identification Methods Used in Isometric Mid-Thigh Pull Test (opens in a new tab)

  2. Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis

    … this project was to develop a single well, 'push-pull' test for the determination of in situ microbial metabolic activities. The method consists of an injection of a test solution into an existing monitoring well followed by the extraction of the groundwater/test solution mixture from the same …

    nps Repository record for Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis (opens in a new tab)

  3. Análise neurofisiológica do equilíbrio através da eletromiografia durante a realização do pull test em indivíduos normais

    … avaliação descritos na literatura, encontra-se o Pull Test (PT), que é amplamente utilizado em escala mundial para avaliação do equilíbrio em indivíduos com doença de Parkinson. O teste examina a resposta do corpo a um deslocamento corporal posterior, oferecendo um identificador útil da …

    brazil-ufrgs Repository record for Análise neurofisiológica do equilíbrio através da eletromiografia durante a realização do pull test em indivíduos normais (opens in a new tab)

  4. Estudo eletromiográfico dos membros inferiores durante o pull test em indivíduos com doença de Parkinson e parkinsonismo atípico

    … de instabilidade postural nestes pacientes- o Pull test. Métodos: Vinte pacientes (nove com doença de Parkinson, cinco com parkinsonismo atípico e seis controles) foram selecionados para análise do padrão de ativação muscular utilizando eletroneuromiografia de superfície durante uma perturbação …

    brazil-ufrgs Repository record for Estudo eletromiográfico dos membros inferiores durante o pull test em indivíduos com doença de Parkinson e parkinsonismo atípico (opens in a new tab)

  5. Análise eletromiográfica de músculos do membro inferior em pacientes com doença de Parkinson durante a realização do Pull Test

    … (EMG) de superfície durante a realização do Pull Test (PT), em português teste de retropulsão. Padrões de latência e amplitude de ativação dos músculos tibial anterior, gastrocnêmio e bíceps femoral foram comparados durante a realização do PT entre pacientes com DP e indivíduos hígidos. Os …

    brazil-ufrgs Repository record for Análise eletromiográfica de músculos do membro inferior em pacientes com doença de Parkinson durante a realização do Pull Test (opens in a new tab)

  6. Experimental Analysis of the Effects of the Variation of Drawbar Pull Test Parameters for Exploration Vehicles on GRC-1 Lunar Soil Simulant

    A drawbar pull (DP) test procedure was developed at the NASA Glenn Research Center (GRC) for testing and developing designs for off-road vehicles. The motivation was to develop a procedure that would produce repeatable results and could be replicated by other researchers. While developing the test …

    vt Repository record for Experimental Analysis of the Effects of the Variation of Drawbar Pull Test Parameters for Exploration Vehicles on GRC-1 Lunar Soil Simulant (opens in a new tab)

  7. Memory Response: Exposure history dependence of microbial mediated transformations of substrates in groundwater

    … situ</em>, by utilizing the single-well push-pull test method. In the first study, the re-oxidation/mobility of uranium, in the presence of nitrate oxidant, was shown to be mitigated by preferential oxidation/mobilization of solid-phase, reduced, sulfur-bearing species. These results indicated …

    utk-theses Repository record for Memory Response: Exposure history dependence of microbial mediated transformations of substrates in groundwater (opens in a new tab)

  8. Analysis of adhesion test methods and the evaluation of their use for ion beam mixed metal/ceramic systems

    <p>Several thin film adhesion tests have been examined to determine which provides the most reliable method for the measurement of the adhesion of thin metallic films to ceramic substrates. An attempt was made to use the testing techniques described to measure adhesion changes caused by ion beam …

    ut-knoxville Repository record for Analysis of adhesion test methods and the evaluation of their use for ion beam mixed metal/ceramic systems (opens in a new tab)

  9. Pulsed Power and Load-Pull Measurements for Microwave Transistors

    … widths between these extremes. A pulsed RF load-pull test bench was also assembled and demonstrated for a VDMOS (Vertically Diffused Metal Oxide Semiconductor) and an LDMOS power transistor. The basic technique should also be useful for GaAs and GaN transistors with suitable consideration for the …

    usf Repository record for Pulsed Power and Load-Pull Measurements for Microwave Transistors (opens in a new tab)

  10. Development of an Advanced Adhesion Test for Polymer Interfaces

    … polymer interfaces. However, typical adhesion testing is normally plagued by large deviations in its test results which make drawing statistical conclusions from adhesion strength data difficult. To remedy this, an investigation into the primary sources of variance associated with the pull test …

    maryland Repository record for Development of an Advanced Adhesion Test for Polymer Interfaces (opens in a new tab)

  11. A Microfabricated Deep Brain Stimulation Electrode

    … is modeled by finite element analysis and tested in vitro to validate the design concept, i.e., targeted stimulation. With monopolar and bipolar configurations, the electric potential in front of the activated site is at least five times larger than that on the other not-activated sides …

    ohiolink Repository record for A Microfabricated Deep Brain Stimulation Electrode (opens in a new tab)

  12. Patterning and adhesion characterization of mettalization for a microelectronics packaging application

    … AS THE WEAK INTERFACE TENSILE STRENGTH BY DIE PULL TEST CONFIRMS THAT UMB (A) AND (D) HAVE WEAK ADHESION STRENGTH AND CAN BE A GOOD RELEASE LAYER FOR STRETCHED SOLDER

    nus Repository record for Patterning and adhesion characterization of mettalization for a microelectronics packaging application (opens in a new tab)

  13. Corrosion of Aluminum Alloys-Polymer Matrix Composite Interfaces in Diverse Natural Atmospheric Environments

    … the samples were then adhesion strength tested by conducting pull test to remove the composite laminate from the aluminum substrate to determine the loss (if any) of the composite laminate adhesion to their respective aluminum substrates. The delaminated samples were then analyzed with a …

    hawaii Repository record for Corrosion of Aluminum Alloys-Polymer Matrix Composite Interfaces in Diverse Natural Atmospheric Environments (opens in a new tab)

  14. Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications

    … assessed by performing first a cyclic fatigue test, and then a tensile loop pull test to failure under saline using an Instron(R) Universal tester. Among the criteria for evaluating the mechanical performance of the knotted loop were the loop elongation at 30N of applied force, the force …

    manitoba Repository record for Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications (opens in a new tab)

  15. Optimization of surface preparation technique for unipolar silicon direct bonding

    … process are examined with crack propagation testing. Bond strength after annealing is sufficient to withstand a pull test, however, with a 3 point bend testing, the crack propagated horizontally at the interface.

    vt Repository record for Optimization of surface preparation technique for unipolar silicon direct bonding (opens in a new tab)

  16. Push-Pull Tests to Support In Situ Chemical Oxidation System Design

    … and efficiency of an ISCO treatment system. Push-pull tests (PPTs) have the utility to estimate key properties in situ and allow for sampling a larger volume of aquifer to yield more representative estimates as compared to conventional bench-scale tests. The scale and cost-effectiveness of a PPT …

    waterloo Repository record for Push-Pull Tests to Support In Situ Chemical Oxidation System Design (opens in a new tab)

  17. Nonlinear finite element analysis of sheet pile interlocks

    … of a sheet pile interlock connection in an axial pull test. Two types of sheet piles, PS32 and PSX32, are considered. The thumb and finger in the interlock of a sheet pile will provide three contact points for connection with another sheet pile. The problem is highly nonlinear in nature which …

    vt Repository record for Nonlinear finite element analysis of sheet pile interlocks (opens in a new tab)

  18. An Examination of the Cardiothoracic Tissue Biophysical Response to Electroporation Therapies

    … muscle baths. Following this, a uniaxial pull test was performed to evaluate any effects on tissue integrity. Phrenic nerve functional response to electroporation was evaluated with elicited compound action potential recordings. The complete dataset provides an understanding of how to …

    umn Repository record for An Examination of the Cardiothoracic Tissue Biophysical Response to Electroporation Therapies (opens in a new tab)

  19. PACKAGE CRACKING MECHANISM IN PLASTIC ENCAPSULATED INTEGRATED CIRCUIT DEVICES

    … one obtained in the commonly conducted adhesion (pull) test. In other words, an adhesion test is carried out to measure the maximum force required to pull a strip of pad material embedded in a block of the particular moulding compound which has been subjected to the same thermal stressing …

    nus Repository record for PACKAGE CRACKING MECHANISM IN PLASTIC ENCAPSULATED INTEGRATED CIRCUIT DEVICES (opens in a new tab)

Page 1 of 3