Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 102 for “"pullout tests"”.

  1. Analysis of dredge materials and crushed glass blends with uniaxial geogrids in pullout tests

    … of a well-documented uniform sand; compare the pullout data with that of previous studies related to the presence of fines in the fill material; and compare the pullout data to that of previous studies on the effect of geogrid rib thickness. The main findings of this thesis study include the …

    texas Repository record for Analysis of dredge materials and crushed glass blends with uniaxial geogrids in pullout tests (opens in a new tab)

  2. Numerical modeling and analysis of pullout tests of sheet and geogrid inclusions in sand

    … studying the soil-inclusion interaction in the pullout test is by numerical modeling. Several of the numerical studies available in the literature lack the integration of consistent material characterization as input for the numerical model, resulting in little phenomenological description of …

    ubc Repository record for Numerical modeling and analysis of pullout tests of sheet and geogrid inclusions in sand (opens in a new tab) Download PDF for Numerical modeling and analysis of pullout tests of sheet and geogrid inclusions in sand (opens in a new tab)

  3. Evaluation of soil-geogrid interaction at different load levels using pullout tests and transparent soil

    … interaction that develop at different stages of pullout tests, especially at small displacements and strains. Moreover, the behavior of transverse ribs throughout pullout testing is evaluated. Pullout loads were obtained from a load cell synchronized with two 5 MP cameras. Images of the geogrid …

    texas Repository record for Evaluation of soil-geogrid interaction at different load levels using pullout tests and transparent soil (opens in a new tab)

  4. A GFRP Bar Bond Stress and Strength: Comparison of Beam-bond and Pullout Tests Results

    … In addition, two Modified and ten Standard pullout specimens were tested using the same bar. The beam-bond and the Modified pullout specimens had embedment length of 600 𝑚𝑚 while the Standard pullout specimens had, in accordance with CSA S806, 60 𝑚𝑚 embedment, or four times the bar nominal …

    mcmaster Repository record for A GFRP Bar Bond Stress and Strength: Comparison of Beam-bond and Pullout Tests Results (opens in a new tab)

  5. Soil-geosynthetics interaction in geosynthetics reinforced soil wall

    … few years at NUS was concentrating on laboratory pullout tests and on the investigation of the drainage capability of geotextile. Only limited numbers of field pullout test on geotextile was conducted at Bukit Panjang, Singapore. Present research focus on the field and laboratory pullout tests in …

    nus Repository record for Soil-geosynthetics interaction in geosynthetics reinforced soil wall (opens in a new tab) Download file for Soil-geosynthetics interaction in geosynthetics reinforced soil wall (opens in a new tab)

  6. On the comparative behaviour of geogrids in tension and pullout

    … were utilised to investigate the tensile and pullout characteristics of three commercially available geogrids. The geosynthetics represent two different types of geogrid: those of low and high junction strength. Unconfined tensile tests were carried out with an industrial (Instron) testing …

    ubc Repository record for On the comparative behaviour of geogrids in tension and pullout (opens in a new tab) Download PDF for On the comparative behaviour of geogrids in tension and pullout (opens in a new tab)

  7. Evaluating the Role of Geogrids in the Rehabilitation of Cracked Dams via Numerical Techniques

    … data to evaluate the behavior of geogrids during pullout tests under various normal stresses. The pullout tests were also modelled using numerical techniques to correlate physical test data with numerical test data. Understanding the behavior of the geogrid, in both the physical and numerical …

    portland-state Repository record for Evaluating the Role of Geogrids in the Rehabilitation of Cracked Dams via Numerical Techniques (opens in a new tab)

  8. Fire Performance of FRP: Bond of GFRP Bars to Concrete and FRP Strengthened Columns

    Standard pullout tests (e.g. 200 mm cubes) with a short embedment length have shown a significant reduction (80% loss at 200 °C) in the bond strength of GFRP bars at high temperatures. More detailed bond behaviour of glass fibre reinforced polymer (GFRP) reinforcing bars has been examined in this …

    queens Repository record for Fire Performance of FRP: Bond of GFRP Bars to Concrete and FRP Strengthened Columns (opens in a new tab)

  9. Local Displacements and Load Transfer of Shape Memory Alloys in Polymeric Matrices

    … SMA and an epoxy matrix were measured using pullout tests. The effects of various mechanical and chemical surface treatments on the bond strengths were examined. In-situ out-of-plane displacements of two-way trained SMA wires in epoxy were measured using heterodyne microinterferometry. The …

    uiuc Repository record for Local Displacements and Load Transfer of Shape Memory Alloys in Polymeric Matrices (opens in a new tab)

  10. PULLOUT RESPONSE OF HIGH-STRENGTH GEOTEXTILE IN REGIONAL SOILS

    … application will be evaluated. Two series of pullout tests, one in sand and one in residual soil, were conducted in this project. Of the pullout tests conducted in sand, one was conducted under dry sand conditions while the other was conducted under wet sand conditions. This series of tests …

    nus Repository record for PULLOUT RESPONSE OF HIGH-STRENGTH GEOTEXTILE IN REGIONAL SOILS (opens in a new tab) Download file for PULLOUT RESPONSE OF HIGH-STRENGTH GEOTEXTILE IN REGIONAL SOILS (opens in a new tab)

  11. Glass Fiber Reinforced Polymer Bars as the Top Mat Reinforcement for Bridge Decks

    … The experimental program included 47 tensile tests and 42 beam end bond tests performed with FRP bars. Tensile strength of the bars from the tensile testing ranged from 529 MPa to 859 MPa. The average modulus, taken from all the testing, for each type of bar was found to range from 40 GPa to …

    vt Repository record for Glass Fiber Reinforced Polymer Bars as the Top Mat Reinforcement for Bridge Decks (opens in a new tab)

  12. Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands

    … prestressing strand of various sizes. Tension tests were performed on each type of strand. The data from these tests was used to determine modulus of elasticity, yield stress, ultimate stress, and ultimate elongation for each strand. The yield stresses and ultimate stresses for many of the …

    vt Repository record for Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands (opens in a new tab)

  13. Pullout Resistance of MSE Wall Steel Strip Reinforcement in Uniform Aggregate

    … anchorage. In the current MSE wall design, pullout capacity of steel strips is evaluated to ensure internal stability of the reinforced mass. The pullout resistance of reinforcement is expressed in terms of a pullout resistance factor that measures the reinforcement-backfill interaction. …

    ku Repository record for Pullout Resistance of MSE Wall Steel Strip Reinforcement in Uniform Aggregate (opens in a new tab)

  14. Experimental study of shape memory alloy connection in precast concrete shear walls for seismic applications

    … of SMA PC walls. Additionally, four coupler pullout tests and seven pullout tests of rebar in concrete blocks were carried out to investigate the effectiveness of the anchorage of the SMA rebar connected with the coupler and surrounding grout within a metal duct. The test results ensured the …

    ubc Repository record for Experimental study of shape memory alloy connection in precast concrete shear walls for seismic applications (opens in a new tab) Download PDF for Experimental study of shape memory alloy connection in precast concrete shear walls for seismic applications (opens in a new tab)

  15. Design parameters for using controlled low-strength material backfill to manage axial soil loads on buried pipelines

    … Columbia. First, twenty-two pipe-CLSM axial pullout tests were completed to assess the bond strength at the interface between CLSM and NPS 8 steel pipe specimens with various coatings. The research findings are presented, and the bond strength is assessed as a percentage of compressional …

    ubc Repository record for Design parameters for using controlled low-strength material backfill to manage axial soil loads on buried pipelines (opens in a new tab) Download PDF for Design parameters for using controlled low-strength material backfill to manage axial soil loads on buried pipelines (opens in a new tab)

  16. Exploring Chemically Treated Fiber Reinforced Pervious Concrete Through Image Based Micromechanical Modeling

    … and Atomic Force Microscopy (AFM). Single fiber pullout tests are conducted to study the effect of the treatment type on fiber-cement interface properties. Treated fibers are then put into pervious concrete matrix for compressive and flexural strength tests. With the chemical treated fibers, 2D …

    ndsu Repository record for Exploring Chemically Treated Fiber Reinforced Pervious Concrete Through Image Based Micromechanical Modeling (opens in a new tab)

  17. Steel and Geosynthetic Reinforcement-Soil Interaction

    … the soil-reinforcement interaction during pullout tests and during direct shear tests using experimental and numerical modeling. The influence of the rib spacing, soil density, grain size, and confining stress on the interface shear strength and pullout force were evaluated. Furthermore, …

    tamu Repository record for Steel and Geosynthetic Reinforcement-Soil Interaction (opens in a new tab)

Page 1 of 6