Showing 1 to 7 of 7 for “"pulsatile flow system"”.
-
Catheter Validation within a Simulated Pulsatile Flow System
… thesis contains a study that used a simulated pulsatile flow system to perform catheter validation using distance interferometers. A synthetic artery composed of Ninjaflex, a formulated thermoplastic polyurethane material, was set up within an ex vivo system. The artery was used to mimic the …
-
Indirect estimation of parameters in a flexible tube, pulsatile flow system
<p>A mathematical model of pulsatile flow and pressure in a flexible tube with a possible branch and stenosis, or constriction, was formulated. Solution of the model equations was performed by the finite element method and a numerical integration procedure. An in vitro experimental model of …
-
Development of an in vitro model of functional mitral valve regurgitation
… or papillary muscle repositioning in a static flow system. Both techniques were individually able to significantly increase the regurgitant volume from baseline (annular dilation: baseline 15.5ml/10s to 78.7 ± 35.3 ml/10s, p =0.02, patch: baseline 7.6ml/10s to 67.4 ± 30.4 ml/10s, p =0.02) with …
-
An examination of flow characteristics in collapsing elastic tubes
… mechanism was incorporated into a recirculating pulsatile flow system to simulate the physiologic problem cf coronary artery vasospasm. A dimensional analysis of the hemodynamic problem provided the basis for i) the specifications for elastic test sections (both straight and branching), ii) the …
-
Improving Quantification of Mitral Regurgitation Through Computational Fluid Dynamics and Ex Vivo Testing
… fluid dynamic simulations. Both a steady and pulsatile flow system were created to test clinical applications used to quantify MR using the PISA method. A total of six computational fluid dynamic cases were then studied; three native mitral valves effected by MR as well as three valves …
-
Tissue Engineering of Human Cardiovascular Patches
… In the current experiment, we developed a pulsatile flow system that provides biochemical and biomechanical signals in order to regulate autologous patch-tissue development in vitro. Methods: We constructed a biodegradable and biocompatible patch scaffold from porous poly-4-hydroxy- …
-
Development of an ex vivo pulsatile heart model of functional mitral regurgitation to facilitate posterior papillary muscle geometric studies and subvalvular surgical strategy
… number of cases. Developing an ex vivo pulsatile functional mitral regurgitation (FMR) heart model by left ventricular (LV) dilatation can be a favorable option for usage in the primary stages of developing new surgical techniques that adjunctively targets the posterior papillary muscle …