Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"pulsation frequency"”.

  1. Influence of liquid properties and process parameters on nanoelectrospray behaviour in both continuous and pulsed voltage operation

    … both a continuous and pulsed voltage, where both pulsation and stable cone-jet modes were observed. In continuous voltage operation the pulsation frequency (f) increases linearly with the applied voltage. Plotting the effect of the emitter outer diameter (OD) on the pulsation frequency against the …

    east-anglia Download PDF for Influence of liquid properties and process parameters on nanoelectrospray behaviour in both continuous and pulsed voltage operation (opens in a new tab)

  2. STUDIES ON GRANULATION, DRYING AND TRIBOCHARGING BEHAVIOUR OF PHARMACEUTICAL POWDERS IN A FLUIDIZED BED DRYER

    … of pharmaceutical granules was investigated in a pulsation-assisted fluidized bed dryer. It was found that pulsed airflow is effective in eliminating channeling and enhancing the drying rate at higher superficial gas velocity. Lower pulsation frequency is more favoured to improve the drying rate. …

    sask Repository record for STUDIES ON GRANULATION, DRYING AND TRIBOCHARGING BEHAVIOUR OF PHARMACEUTICAL POWDERS IN A FLUIDIZED BED DRYER (opens in a new tab)

  3. FORWARD HEATING IN WIND-DRIVEN FLAMES

    … where the Rix equaled unity. The flame forward pulsation frequency and the flame-fuel contact frequency were also extracted. Scaling analysis indicates that they can be well correlated with Fr, Q*, and local Rix respectively. The location of maximum pulsation frequency, xmax, for each …

    maryland Repository record for FORWARD HEATING IN WIND-DRIVEN FLAMES (opens in a new tab)

  4. The Impact of High Frequency Flow Pulsation on Fluidised Bed Drying

    … in efficiencies are widely desirable. Low frequency flow pulsation has been found in the literature to reduce gas pumping requirements in fluidised beds and increase drying rates. However, research to date has used pulsation frequency range that tends to be within a 1-15 Hz limit. …

    whiterose Download file for The Impact of High Frequency Flow Pulsation on Fluidised Bed Drying (opens in a new tab)

  5. Pipeline Pulsing Flow of Slurries

    … following pertinent flow variables were studied: pulsation frequency, pulsation amplitude, average slurry velocity, solids volume concentration, mean particle size and the presence of a small amount of ultra fine particles in coarse solid liquid mixtures.</p> <p>The experimental results of pulsing …

    mcmaster Repository record for Pipeline Pulsing Flow of Slurries (opens in a new tab)

  6. Cavitation of a Water Jet in Water

    … propagation distance, cloud width and area, pulsation frequency, and cloud front velocity are presented. Among the results is a discussion of the significant experimental factors affecting the behavior of the cavitation clouds. It is shown that the Reynolds number, specifically the diameter …

    byu Repository record for Cavitation of a Water Jet in Water (opens in a new tab) Download PDF for Cavitation of a Water Jet in Water (opens in a new tab)

  7. Pulsation Assisted Fluidized Bed for Potash Drying to Eliminate Agglomeration and Enhance Energy and Exergy Efficiency

    … bubble velocity, average bubble size, and bubble frequency in both bubbling and slugging regimes were measured and compared at two heights of potash bed using a twin-plane ECT system. The experimental data for bubble diameter and bubble rise velocity were validated by the model of Agu et al. with …

    sask Repository record for Pulsation Assisted Fluidized Bed for Potash Drying to Eliminate Agglomeration and Enhance Energy and Exergy Efficiency (opens in a new tab)

  8. Numerical investigation on laminar pulsating flow through porous media

    … in the porosity range of 0.64 to 0.84, with flow pulsation frequency of 40 Hz were obtained, and special attention was paid to the phase shift characteristics between the velocity and pressure waves. Based on these detailed numerical data, the standard unsteady volume-averaged momentum …

    gatech Repository record for Numerical investigation on laminar pulsating flow through porous media (opens in a new tab)

  9. Experimental and theoretical study on the ejected facade flame behavior from compartment fires under different ventilation conditions

    … for which there is still lack of research; flame pulsation behaviour of the external venting facade fire is an inherent characteristic of the ejected facade flame, for which no work has been reported. In addition, the environment wind is one of the important boundary conditions for the building …

    ghent Repository record for Experimental and theoretical study on the ejected facade flame behavior from compartment fires under different ventilation conditions (opens in a new tab)

  10. An Underwater Explosion-Induced Ship Whipping Analysis Method for use in Early-Stage Ship Design

    … keel near midship and produces a bubble with a pulsation frequency similar to the natural vibration frequency of the ship in its third mode. Significant damage to the ship structure and hull girder collapse is possible as a result of these loads.

    vt Repository record for An Underwater Explosion-Induced Ship Whipping Analysis Method for use in Early-Stage Ship Design (opens in a new tab)

  11. Heat and mass transfer in pulsed fluidized bed of biomass

    … analyzing the intricate relationship between pulsation frequency, gas flow rate and the hydrodynamics. A two-phase drying model that linked single-particle mass transfer to macroscopic hydrodynamics in fluidized bed was implemented to verify the effect of flow rate, temperature and biomass …

    ubc Repository record for Heat and mass transfer in pulsed fluidized bed of biomass (opens in a new tab) Download PDF for Heat and mass transfer in pulsed fluidized bed of biomass (opens in a new tab)

  12. Application of Computational Fluid Dynamics (CFD) to Study Liquefied Natural Gas (LNG) Pool Fires

    … the flame geometry of the experiment considered. Pulsation frequency obtained from FDS was compared with experimental data and thus shows the accuracy of FDS in capturing transient fluctuations of fire.

    tamu Repository record for Application of Computational Fluid Dynamics (CFD) to Study Liquefied Natural Gas (LNG) Pool Fires (opens in a new tab)

  13. A numerical study of pulse-combustor jet impingement heat transfer

    … effects of jet velocity oscillation amplitude, pulsation frequency, mean jet velocity, tailpipe width, and impingement surface velocity. Simulation results showed that the amplitude of jet velocity oscillation was the most important parameter for heat transfer enhancement, in which two …

    gatech Repository record for A numerical study of pulse-combustor jet impingement heat transfer (opens in a new tab)

  14. Predicting Pulsations and Surge in Mixed Reciprocating and Centrifugal Compressor Piping Systems

    … compressor surge in the presence of pressure pulsations in gas transmission lines, and examine the effects of pulsation amplitude and frequency on centrifugal compressor operating stability. Anecdotal field evidence suggests that it is possible for a centrifugal compressor to enter surge when …

    tamu Repository record for Predicting Pulsations and Surge in Mixed Reciprocating and Centrifugal Compressor Piping Systems (opens in a new tab)

  15. Pressure pulsations in sieve-tray columns.

    … conditions. The vibrations result from regular pulsations of the gas flow and pressure in the column. These pulsations have been studied with a 3 m. high perspex model sieve-tray column having a single active test-tray using air and water as process fluids. The effects on the amplitude and …

    whiterose Download PDF for Pressure pulsations in sieve-tray columns. (opens in a new tab)

  16. Biomass torrefaction in a pulsed fluidized bed reactor

    … a candidate for biomass thermal treatment. Gas pulsation has been proven effective in fluidizing biomass particles with unconventional natures that caused problems in fluidization. A novel pulsed fluidized bed (PFB) reactor for continuous biomass torrefaction was designed and commissioned in …

    ubc Repository record for Biomass torrefaction in a pulsed fluidized bed reactor (opens in a new tab) Download PDF for Biomass torrefaction in a pulsed fluidized bed reactor (opens in a new tab)

  17. Enhanced heat transfer in a cylindrical cavity with periodically perturbed annular flames.

    … equivalence ratios ranged from 0.6 to 1.0, the pulsation frequencies from steady to 35 Hz, and the thermal throughputs from 9.6 kW to 16 kW. Tested Reynolds numbers ranged from 1,475 to 3,900 and were based on the diameter and flow rates of the heat transfer test article. Strouhal numbers ranged …

    wvu Repository record for Enhanced heat transfer in a cylindrical cavity with periodically perturbed annular flames. (opens in a new tab)

  18. Trophic Interactions of Hydromedusae Across Multiple Spatial Scales

    … energy and hydromedusan tentacle length and bell pulsation frequency at two sites in Friday Harbor, Washington: a nearshore site protected from the channel flow and the Friday Harbor Marina, influenced by channel flow. The protected site presented a shorter range of turbulence compared to the …

    oregon Repository record for Trophic Interactions of Hydromedusae Across Multiple Spatial Scales (opens in a new tab)

  19. Direct Numerical Simulation of Pulsating Flow in Curved Pipes: Insights into Aortic Dissection in Humans

    … aortic arch are used to isolate the effects of pulsation frequency, amplitude ratio, and curvature ratio on transitional and turbulent flow dynamics. The simulations reveal that curvature-driven centrifugal forces shift the peak velocity toward the outer wall, while transition is initiated on …

    uky-thes Repository record for Direct Numerical Simulation of Pulsating Flow in Curved Pipes: Insights into Aortic Dissection in Humans (opens in a new tab)

  20. Local instantaneous convective heat transfer characteristics from mechanical and supply pulsed radial reattaching nozzles

    … flow guide height (0.8 and 1.16), mechanical pulsation rate (5 and 10 Hz), supply pulsation rate (10, 20, 30, and 40 Hz), phase angle (0° and 180°), and Reynolds number (1683 and 2366). Air was forced through a supply pulsation mechanism and then through a pulsated nozzle diverter apparatus. …

    ttu Repository record for Local instantaneous convective heat transfer characteristics from mechanical and supply pulsed radial reattaching nozzles (opens in a new tab)