Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"pulse contour analysis"”.

  1. Critical Investigation of the Pulse Contour Method for Obtaining Beat-By-Beat Cardiac Output

    … was to explore the efficacy of two existing pulse contour analysis (PCA) models for estimating cardiac stroke volume from the arterial pressure waveform during kicking ergometer exercise and head-up tilt manoeuvres. Secondly, one of the existing models was modified in an attempt to enhance …

    waterloo Repository record for Critical Investigation of the Pulse Contour Method for Obtaining Beat-By-Beat Cardiac Output (opens in a new tab)

  2. Effects of resistance training on arterial elasticity and C-reactive protein in premenopausal women.

    … Large (C1) and small (C2) arterial elasticity (Pulse Contour Analysis), the inflammatory marker, C-reactive protein (CRP), and body composition (DXA) were measured at baseline and after twelve weeks of training. Results. There were no significant (p > 0.05) group differences at baseline in age, …

    oklahoma-thes Repository record for Effects of resistance training on arterial elasticity and C-reactive protein in premenopausal women. (opens in a new tab)

  3. Μελέτη της μεταβολής του δείκτη Pulse Pressure Variation κατά την εφαρμογή Tidal Volume Challenge σε πρηνή και ύπτια θέση σε ασθενείς που υποβάλλονται σε επεμβάσεις σπονδυλοδεσίας

    … στον ασθενή. Οι δυναμικοί δείκτες προφορτίου (Pulse Pressure Variation -PPV , Stroke Volume Variation- SVV) χρησιμοποιούνται για την καθοδήγηση της χορήγησης των υγρών ωστόσο ο μηχανικός αερισμός με χαμηλούς αναπνεόμενους όγκους (tidal volume-VT) επηρεάζει την αξιοπιστία τους. Η δοκιμασία …

    athens Repository record for Μελέτη της μεταβολής του δείκτη Pulse Pressure Variation κατά την εφαρμογή Tidal Volume Challenge σε πρηνή και ύπτια θέση σε ασθενείς που υποβάλλονται σε επεμβάσεις σπονδυλοδεσίας (opens in a new tab)

  4. Does acute hypoxia and high altitude exposure adversely affect cardiovascular performance?

    … portable transthoracic echocardiography and pulse contour analysis respectively. Myocardial injury was measured in venous blood by cardiac troponin T (cTnT) quantification. Cardiac inter-beat interval data for HRV analysis was acquired using single lead ECGs and novel finger and patch sensor …

    bournemouth Download PDF for Does acute hypoxia and high altitude exposure adversely affect cardiovascular performance? (opens in a new tab)

  5. The effect of single nucleotide polymorphisms of oxidative stress genes and low grade inflammation upon pulse wave contour analysis, a useful non invasive, intermediate vascular phenotype.

    … as well as a non invasive vascular phenotype, pulse wave analysis. This thesis reports a series of studies (utilising the techniques described in chapter 2) which aimed to ascertain:- The reproducibility of pulse contour analysis as a non invasive intermediate cardiovascular phenotype (Chapter …

    glasgow Download PDF for The effect of single nucleotide polymorphisms of oxidative stress genes and low grade inflammation upon pulse wave contour analysis, a useful non invasive, intermediate vascular phenotype. (opens in a new tab)

  6. Pulse transit time and the pulse wave contour as measured by photoplethysmography: the effect of drugs and exercise

    … (PPG) is a simple means of measuring the pulse wave in humans, exploitable for the purposes of timing the arrival of the pulse at a particular point in the arterial tree, and for pulse contour analysis. This thesis describes a methodology for measuring arterial pulse transit time (PTT) …

    edinburgh Repository record for Pulse transit time and the pulse wave contour as measured by photoplethysmography: the effect of drugs and exercise (opens in a new tab)

  7. Erfassung der Veränderungen des Schlagvolumens im Rahmen einer intraoperativen, zielgerichteten Hämodynamiktherapie

    Hintergrund: Für ein intraoperatives zielgerichtetes Management der Hämodynamik mittels des ösophagealen Doppler-Monitors (ODM, CardioQ-ODMTM) konnte eine Reduktion der postoperativen Komplikationen gezeigt werden. Das zielgerichtete Management zielt auf eine Optimierung des kardiovaskulären …

    fu-berlin Repository record for Erfassung der Veränderungen des Schlagvolumens im Rahmen einer intraoperativen, zielgerichteten Hämodynamiktherapie (opens in a new tab)