Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"pulse design"”.

  1. RF Pulse Design for Parallel Excitation in Magnetic Resonance Imaging

    … techniques. Then it will present two new RF pulse design methods to achieve reduced local/global SAR for parallel excitation while preserving the time duration and excitation pattern quality. Simulations incorporating human-model based tissue density and dielectric property were performed. …

    tamu Repository record for RF Pulse Design for Parallel Excitation in Magnetic Resonance Imaging (opens in a new tab)

  2. Optimization of a GPU implantation of multi-dimensional RF pulse design algorithm

    Pulse sequences are commonly used for both routine clinical diagnosis and advanced applications. The purpose of the pulse sequence is to manipulate the magnetization in order to produce the desired signal. However, the main drawback is that the calculation takes too much time. This project shows …

    hawaii Repository record for Optimization of a GPU implantation of multi-dimensional RF pulse design algorithm (opens in a new tab)

  3. Time-optimized Radio Frequency pulse design within hardware and sequence constraints for multiband MRI

    … challenges in multiband imaging arise in the design of multiband RF pulses, which can take significantly longer to transmit and consequently lead to lower acquired signal, due to relaxation. Exciting multiple slices also places significant demand on current hardware, in terms of coping with …

    kings Repository record for Time-optimized Radio Frequency pulse design within hardware and sequence constraints for multiband MRI (opens in a new tab) Download PDF for Time-optimized Radio Frequency pulse design within hardware and sequence constraints for multiband MRI (opens in a new tab)

  4. Deep learning applications in magnetic resonance imaging : radiofrequency pulse design and automated real-time quality control

    Deep Learning–Based Design of RF pulses in MRI. Purpose: The development of custom-designed power-independent-of-number of-slices (PINS) RF pulses that yield desirable slice profiles requires time consuming, iterative tuning. The goal of this work was to simplify the design process by training a …

    ubc Repository record for Deep learning applications in magnetic resonance imaging : radiofrequency pulse design and automated real-time quality control (opens in a new tab) Download PDF for Deep learning applications in magnetic resonance imaging : radiofrequency pulse design and automated real-time quality control (opens in a new tab)

  5. High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI

    … transmit (PTx) combined with more advanced pulse design methods is a flexible solution to overcome B+1 inhomogeneity. During my PhD I investigated how to compare different qMRI methods and developed two RF pulse design methods for pTx systems to overcome B+1 inhomogeneity in Magnetization …

    kings Repository record for High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI (opens in a new tab) Download PDF for High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI (opens in a new tab)

  6. Efficient Algorithms for Parallel Excitation and Parallel Imaging with Large Arrays

    … These two techniques lead to shorter transmit pulses for higher imaging quality and faster data acquisition correspondingly. This dissertation focuses on improving the efficiency of the pTx pulse design and the PI reconstruction in MRI. Both PI and pTx benefit from the increased number of …

    tamu Repository record for Efficient Algorithms for Parallel Excitation and Parallel Imaging with Large Arrays (opens in a new tab)

  7. Design of multidimensional radiofrequency pulses in magnetic resonance imaging

    Multidimensional radiofrequency (RF) pulses have wide applications in magnetic resonance imaging and spectroscopy experiments. These applications include reduced field-of-view (FOV) imaging of region-of-interest (ROI), B1 inhomogeneity correction, and simultaneous spatial-spectral selective …

    uiuc Repository record for Design of multidimensional radiofrequency pulses in magnetic resonance imaging (opens in a new tab)

  8. New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI

    … To achieve this, we developed new methods to design radiofrequency (RF) arrays optimized for these purposes. Our approach is to design an eight-channel array coil that is both transmit and receive, and could be used for both types of studies. We focused on optimizing the array for the …

    manitoba Repository record for New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI (opens in a new tab)

  9. Deep Learning Methods for Ultra High Field MRI

    … to address both parallel transmission (pTx) pulse design and image reconstruction. In the first part, we focus on transmit field inhomogeneity correction using pTx. We introduce an unsupervised deep learning framework based on convolutional neural networks (CNNs) to design RF pulses directly …

    umn Repository record for Deep Learning Methods for Ultra High Field MRI (opens in a new tab)

  10. Quantum Information Processing with Spin and Motional States of Trapped Ions

    … and software control of trapped ion systems. We design and construct a compact cryogenic trapped-ion platform that is easy to integrate and manufacture, and characterize the system behavior which shows several advantages over conventional trapped-ion systems in UHV chambers. We develop a robust …

    duke Repository record for Quantum Information Processing with Spin and Motional States of Trapped Ions (opens in a new tab)

  11. Mechanism emulation with a magnetically levitated input/output device

    … used mass-spring-damper model: an observer-based design, and a braking pulse design. The mass-spring-damper model is limited in its achievable stiffness due to instability. Both control methods increased perceived stiffness substantially (stably) for one degree-offreedom. The braking pulse method …

    ubc Repository record for Mechanism emulation with a magnetically levitated input/output device (opens in a new tab) Download PDF for Mechanism emulation with a magnetically levitated input/output device (opens in a new tab)

  12. Improving Circuit Performance in a Trapped-Ion Quantum Computer

    … of robust frequency-modulated two-qubit gate pulse design are introduced. With the state-of-the-art scalable two-qubit gates, we propose a compilation technique, which we refer to as hidden inverses, that creates circuits robust to residual coherent errors. We present experimental data showing …

    duke Repository record for Improving Circuit Performance in a Trapped-Ion Quantum Computer (opens in a new tab)

  13. Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.

    … Multidimensional spatially selective RF pulses have been proposed as a method to mitigate B1+ inhomogeneity. However, those RF pulses are typically very long and are impractical at high field. Parallel transmission, an emerging technique, makes it possible to design sufficiently short …

    umn Repository record for Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System. (opens in a new tab)

  14. Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging

    … utilization. In literature, radiofrequency pulse design and multi-acquisition methods with and without parallel transmission systems have been demonstrated for addressing the transmit field inhomogeneity. While substantial improvements have been demonstrated with these methods, they can be …

    utswmed Repository record for Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging (opens in a new tab)

  15. Transformuojamas paauglio baldo projektas /

    … Led švietuvų film eloquently reveals the subtle design accentuate the furniture separate zones. In the evening, allowing the sunset can be activated LED lights installed furniture, a grand sparkle at dusk is the main piece of furniture and home accents. The design of the selected piece of …

    vilnius Repository record for Transformuojamas paauglio baldo projektas / (opens in a new tab)

  16. Optimal encoding of quantum information into a propagating mode

    … models, and that both pulse design and the choice of confinement mechanism play an important role in the quality of the transferred state.

    chalmers Repository record for Optimal encoding of quantum information into a propagating mode (opens in a new tab)

  17. Robust control of quantum processors using space curves

    … combine them with numerical optimization, where pulse properties are treated as optimization goals. Analytical constraints are always met exactly, but numerically optimized goals may only be satisfied approximately, leading to tradeoffs. Therefore, a modular analytical framework is needed that …

    vt Repository record for Robust control of quantum processors using space curves (opens in a new tab)

  18. Variation in wing area and prey detection volume of Rhinolophus Capensis in response to different climates

    … conditions also influence echolocation pulse design. Echolocation pulses must successfully reach a target and generate an audible echo despite atmospheric attenuation. High-duty cycle (HDC) pulses, calls with longer durations than the interval between them, are particularly useful in …

    cape-town Repository record for Variation in wing area and prey detection volume of Rhinolophus Capensis in response to different climates (opens in a new tab)

Page 1 of 2