Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"pulse-height spectroscopy"”.
-
Design, Fabrication and Characterization of a Unipolar Charge Sensing Amorphous Selenium X-ray Detector
… can persist for several seconds after the X-ray pulse has ended. As a result, a-Se is a challenging material for dynamic imaging applications that require high spatial resolution. The research discussed in this thesis aims to investigate and address the temporal behavior of a-Se photoconductors, …
-
Device Architectures for Improved Temporal Response with Amorphous Selenium Radiation Detectors
… several seconds after the cessation of the X-ray pulse, thus making a-Se a challenging material for use in high spatial resolution dynamic imaging applications. In this research, the intrinsic causes of temporal behavior in a-Se photoconductor are investigated using lag, ghosting and pulse height …
-
High Resolution Radiation Detectors Based On 4H-SiC N-Type Epitaxial Layers And Pixilated CdZnTe Single Crystal Devices
… (I-V) measurements revealed Schottky barrier heights of the order of 1.7 eV, ideality factor of ~1.1, and leakage currents as low as 1 nA at an operating reverse bias of -170 V. Deep level transient spectroscopy (DLTS) revealed the presence of shallow defects at Ec – (0.14 ± 0.01) eV and Ec – …
-
Monolithic Amorphous-Selenium/CMOS Small-Pixel-Effect-Enhanced Single-Photon-Counting Imagers for Dedicated Breast Computed Tomography
… a-Se/CMOS imager and the first measured pulse-height spectroscopy results using our designed CMOS ROIC (Chip 2). We also experimentally demonstrate the small-pixel effect (SPE) with an a-Se/CMOS detector for the first time and show its potential to dramatically improve energy resolution …
-
Improved N-Type 4h-Sic Epitaxial Layer Radiation Detectors and Noise Analysis of Front-End Readout Electronics
… model, junction properties such as barrier height of ≥1.10 eV and an ideality factor of ≤1.29 were determined. An effective carrier concentration of 1.03×1015 cm-3 was calculated by capacitance-voltage (C-V) measurement. Deep level transient spectroscopy (DLTS) was used to investigate …
-
Room Temperature Semiconductor Radiation Detectors Based on CdZnTe and CdZnTeSe
… The pixels exhibited well-resolved gamma pulse-height spectra with energy resolution ~ 1.5% at 662 keV. A few pixels exhibited tailing of the photopeak on the lower energy side indicating the presence of hole traps. Biparametric plots (BP) were generated from digitally recorded …
-
Defect Characterization of 4H-SIC by Deep Level Transient Spectroscopy (DLTS) and Influence of Defects on Device Performance
… the fabricated devices, those with high barrier height (~ 1.6 eV) and extremely low leakage current (few pA at a reverse bias of ~ -100 V) were selected for alpha spectroscopic measurements. Alpha pulse-height spectra was obtained from the charge pulses produced by the detector irradiated with a …