  1. Design, Fabrication and Characterization of a Unipolar Charge Sensing Amorphous Selenium X-ray Detector

    … can persist for several seconds after the X-ray pulse has ended. As a result, a-Se is a challenging material for dynamic imaging applications that require high spatial resolution. The research discussed in this thesis aims to investigate and address the temporal behavior of a-Se photoconductors, …

    waterloo Repository record for Design, Fabrication and Characterization of a Unipolar Charge Sensing Amorphous Selenium X-ray Detector (opens in a new tab)

  2. Device Architectures for Improved Temporal Response with Amorphous Selenium Radiation Detectors

    … several seconds after the cessation of the X-ray pulse, thus making a-Se a challenging material for use in high spatial resolution dynamic imaging applications. In this research, the intrinsic causes of temporal behavior in a-Se photoconductor are investigated using lag, ghosting and pulse height …

    waterloo Repository record for Device Architectures for Improved Temporal Response with Amorphous Selenium Radiation Detectors (opens in a new tab)

  3. High Resolution Radiation Detectors Based On 4H-SiC N-Type Epitaxial Layers And Pixilated CdZnTe Single Crystal Devices

    … (I-V) measurements revealed Schottky barrier heights of the order of 1.7 eV, ideality factor of ~1.1, and leakage currents as low as 1 nA at an operating reverse bias of -170 V. Deep level transient spectroscopy (DLTS) revealed the presence of shallow defects at Ec – (0.14 ± 0.01) eV and Ec – …

    south-carolina Repository record for High Resolution Radiation Detectors Based On 4H-SiC N-Type Epitaxial Layers And Pixilated CdZnTe Single Crystal Devices (opens in a new tab)

  4. Monolithic Amorphous-Selenium/CMOS Small-Pixel-Effect-Enhanced Single-Photon-Counting Imagers for Dedicated Breast Computed Tomography

    … a-Se/CMOS imager and the first measured pulse-height spectroscopy results using our designed CMOS ROIC (Chip 2). We also experimentally demonstrate the small-pixel effect (SPE) with an a-Se/CMOS detector for the first time and show its potential to dramatically improve energy resolution …

    waterloo Repository record for Monolithic Amorphous-Selenium/CMOS Small-Pixel-Effect-Enhanced Single-Photon-Counting Imagers for Dedicated Breast Computed Tomography (opens in a new tab)

  5. Improved N-Type 4h-Sic Epitaxial Layer Radiation Detectors and Noise Analysis of Front-End Readout Electronics

    … model, junction properties such as barrier height of ≥1.10 eV and an ideality factor of ≤1.29 were determined. An effective carrier concentration of 1.03×1015 cm-3 was calculated by capacitance-voltage (C-V) measurement. Deep level transient spectroscopy (DLTS) was used to investigate …

    south-carolina Repository record for Improved N-Type 4h-Sic Epitaxial Layer Radiation Detectors and Noise Analysis of Front-End Readout Electronics (opens in a new tab)

  6. Room Temperature Semiconductor Radiation Detectors Based on CdZnTe and CdZnTeSe

    … The pixels exhibited well-resolved gamma pulse-height spectra with energy resolution ~ 1.5% at 662 keV. A few pixels exhibited tailing of the photopeak on the lower energy side indicating the presence of hole traps. Biparametric plots (BP) were generated from digitally recorded …

    south-carolina Repository record for Room Temperature Semiconductor Radiation Detectors Based on CdZnTe and CdZnTeSe (opens in a new tab)

  7. Defect Characterization of 4H-SIC by Deep Level Transient Spectroscopy (DLTS) and Influence of Defects on Device Performance

    … the fabricated devices, those with high barrier height (~ 1.6 eV) and extremely low leakage current (few pA at a reverse bias of ~ -100 V) were selected for alpha spectroscopic measurements. Alpha pulse-height spectra was obtained from the charge pulses produced by the detector irradiated with a …

    south-carolina Repository record for Defect Characterization of 4H-SIC by Deep Level Transient Spectroscopy (DLTS) and Influence of Defects on Device Performance (opens in a new tab)