Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"pulsed-RF"”

  1. New Pulsed-IV Pulsed-RF Measurement Techniques For Characterizing Power FETs For Pulsed-RF Power Amplifier Design

    … from devices exhibiting slow memory effects, a pulsed-IV pulsed-RF (pulsed-IV/RF) measurement system using a large signal network analyzer (LSNA) was implemented. The measurement scheme based on a short pulse width and low duty rate in both pulsed-IV and pulsed-RF signals makes it possible to …

    ohiolink Repository record for New Pulsed-IV Pulsed-RF Measurement Techniques For Characterizing Power FETs For Pulsed-RF Power Amplifier Design (opens in a new tab)

  2. BiCMOS Power Detector for Pulsed RF Power Amplifiers

    A BiCMOS power detector for pulsed radio-frequency power amplifiers is proposed. Given the pulse waveform and a fraction of the power amplifier’s input or output signal, the detector utilizes a low-frequency feedback loop to perform a successive approximation of the amplitude of the input signal. …

    tamu Repository record for BiCMOS Power Detector for Pulsed RF Power Amplifiers (opens in a new tab)

  3. Pulsed RF Circuits for Ultra Wideband Communications and Radar Applications

    … the design of fast-settling pulse generators and pulsed low noise amplifiers (LNAs) for Ultra-Wideband (UWB) applications. These components are critical in pulsed UWB transceivers, and a high energy efficiency is sought without adversely affecting RF performance and functionality. To this end, new …

    queens Repository record for Pulsed RF Circuits for Ultra Wideband Communications and Radar Applications (opens in a new tab)

  4. Numerical simulation of the excitation of a multi-cell resonator by a pulsed electron beam

    … simulation of the interaction between a pulsed relativistic electron beam and a multi-cell resonator structure with application to the analysis of a relativistic extended interaction klystron. Pulsed RF fields are produced of order IOMV/m at lOGHz. Excitation of then mode of the resonator …

    ttu Repository record for Numerical simulation of the excitation of a multi-cell resonator by a pulsed electron beam (opens in a new tab)

  5. The Relevance Of Time-to-digital Converters To Small Platform Direction Finding Systems

    … By measuring the relative time of arrival of a pulsed RF signal impinging on an antenna array, direction of arrival (DOA) can be ascertained. This technology enables versatile DOA calculation on platforms only several meters in length, and offers various size, weight, power, and cost advantages …

    ucf Repository record for The Relevance Of Time-to-digital Converters To Small Platform Direction Finding Systems (opens in a new tab)

  6. Pulsed Power and Load-Pull Measurements for Microwave Transistors

    … and/or validating electro-thermal models using pulsed I(V) measurements and pulsed I(V) simulations demonstrated using modifications of an available non-linear model for an LDMOS (Laterally Diffused Metal Oxide Semiconductor) device. After extracting the thermal time constant, good agreement is …

    usf Repository record for Pulsed Power and Load-Pull Measurements for Microwave Transistors (opens in a new tab)

  7. Plasma chemical driven biomedical applications with a radio frequency driven atmospheric pressure plasma jet

    … to the Cl radical density in the plasma jet. Pulsed RF provided another knob to control the removal profile, heat damage, and removal rate. Hydrogen peroxide (H2O2) additive provided abundant OH generation in the helium plasma jet. It not only enhanced tissue removal rate but also reduced heat …

    colostate Repository record for Plasma chemical driven biomedical applications with a radio frequency driven atmospheric pressure plasma jet (opens in a new tab)

  8. Trapping Effects in AlGaN/GaN HEMTs for High Frequency Applications : Modeling and Characterization Using Large Signal Network Analyzer and Deep Level Optical Spectroscopy

    … defect site could impact the device performances during practical device operation. In this study, the g oal is (1) to give device engineers ideas on how further improvements can be devised to strengthen the existing GaN technology and (2) to provide circuit designers with better …

    ohiolink Repository record for Trapping Effects in AlGaN/GaN HEMTs for High Frequency Applications : Modeling and Characterization Using Large Signal Network Analyzer and Deep Level Optical Spectroscopy (opens in a new tab)

  9. Using Plasmas for High-Speed Flow Control and Combustion Control

    … and combustion control have been discussed. Pulsed DC and pulsed RF actuator discharge power measurements and plasma temperature measurements demonstrated that rapid localized heating, at a rate of 1000 degrees C / 10 μs, can be achieved at low time-averaged actuator powers, 10-20 W for 10% …

    ohiolink Repository record for Using Plasmas for High-Speed Flow Control and Combustion Control (opens in a new tab)

  10. State-selective imaging of single rubidium atoms in a solid neon matrix

    … which is useful for avoiding noise from the surface. We begin with an overview of relevant optical and magnetic properties of the trapped Rb atoms, measured using an ensemble of atoms, that are critical for quantum sensing of magnetic fields. These include the absorption and fluorescence …

    unr Repository record for State-selective imaging of single rubidium atoms in a solid neon matrix (opens in a new tab)

  11. Study in analytical glow discharge spectrometry and its application in materials science

    … analysis of solid samples. The application of a pulsed power supply to the glow discharge (GD) has a number of advantages in comparison with a continuous one and thereby broadens the analytical potential of the GD. However, because the pulsed GD (PGD) is a relatively new operation mode, the …

    qucosa-diss Repository record for Study in analytical glow discharge spectrometry and its application in materials science (opens in a new tab)

  12. Improved Techniques for Nonlinear Electrothermal FET Modeling and Measurement Validation

    … trapping effects. Demonstration of a customized pulsed-bias, pulsed-RF S-parameter system constructed by the author using a traditional vector network analyzer is presented, along with the design of special bias tees to allow pulsing of the bias voltages. Pulsed IV and pulsed-bias S-parameter …

    usf Repository record for Improved Techniques for Nonlinear Electrothermal FET Modeling and Measurement Validation (opens in a new tab)

  13. Carrier dynamics in high-speed III-nitride light-emitting diodes for visible-light communication

    … in electrically injected LEDs using small-signal RF measurements and differential rate equation analysis. This method represents an entirely new approach to characterizing the classic DC properties of III-nitride LEDs and enables simultaneous determination of the dynamic properties. This method …

    unm Repository record for Carrier dynamics in high-speed III-nitride light-emitting diodes for visible-light communication (opens in a new tab)

  14. Nonlinear Device Measurement, Characterization, and Modeling for High Power RF Applications

    … power and frequency requirements for commercial RF applications, various semiconductor materials and device structures have been introduced and developed rapidly. These semiconductors need to handle modulated signals exhibiting high peak to average power ratio (PAPR) and wide modulation bandwidth …

    ohiolink Repository record for Nonlinear Device Measurement, Characterization, and Modeling for High Power RF Applications (opens in a new tab)

  15. APPLICATION OF MACHINE LEARNING FOR PREDICTING IEMI UPSET IN MULTI-ARCHITECTURE MICROCONTROLLERS

    … programmed to execute a simple counting program. Pulsed RF signals – also known as Intentional ElectroMagnetic Interference (IEMI) – were injected into the clock input of the microcontrollers. At the same time, the output lines were monitored to determine whether the IEMI signal altered the output …

    unm Repository record for APPLICATION OF MACHINE LEARNING FOR PREDICTING IEMI UPSET IN MULTI-ARCHITECTURE MICROCONTROLLERS (opens in a new tab)

  16. Analysis and design of ΣΔ Modulators for Radio Frequency Switchmode Power Amplifiers

    … was considered for reducing power losses in a RF transmitter. A linear and efficient operation of a PA can be achieved when the transmitted RF signal is ΣΔ modu- lated, and subsequently amplified by a nonlinear device. Although in theory this approach offers linearity and efficiency reaching …

    maynooth Repository record for Analysis and design of ΣΔ Modulators for Radio Frequency Switchmode Power Amplifiers (opens in a new tab)

  17. Aktyviai sinchronizuotų modų skaidulinio lazerinio šaltinio, veikiančio 1570 nm bangos ilgių srityje, charakterizavimas ir optimizavimas /

    … The aim of this work is to investigate the performance of an actively mode-locked fiber laser source operating at 1570 nm wavelength and the pulse generation characteristics by varying the active modulation frequency, modulation depth and spectral filtering. Fiber laser circuit with an …

    vilnius Repository record for Aktyviai sinchronizuotų modų skaidulinio lazerinio šaltinio, veikiančio 1570 nm bangos ilgių srityje, charakterizavimas ir optimizavimas / (opens in a new tab)

  18. Design of control release drug delivery system (DDS) for imaging and therapeutic applications

    … dye from the PLGA composites when placed in the Rf induction coil was determined by fluorescence spectroscopy and a linear increase in the fluorescent intensity was observed with time. Also, the controlled release of the dye from the composites was achieved by a pulsed Rf treatment. Magnetic …

    vcu Repository record for Design of control release drug delivery system (DDS) for imaging and therapeutic applications (opens in a new tab)

Page 1 of 2