Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"pumping chamber"”.
-
The design, development and in vitro testing of an electric motor driven artificial heart
The blood pumping chambers and drive pump for a totally implantable artificial heart have been developed at the biomedical engineering laboratory. The drive pump is driven by an electric motor and provides alternate pumping of the blood pumping chambers. The blood pumping chambers are diaphragm …
-
Development of a Magneto-Rheological Fluid Based Actuation System
… model was developed to understand the effect of pumping chamber geometry on the pressure losses in the pumping chamber. Three dimensional analytical models were developed for steady and unsteady flow and the results were correlated to results obtained from Computation Fluid Dynamic simulation of …
-
Noise due to pressure pulsations in a pressure-balanced sliding vane pump
… which was a function of three clearances in the pumping chamber, determined the magnitude of the pressure pulsations. If the pumping chamber components had inadequate clearances, the pump produced excessive pressure pulsations for a given discharge pressure and, consequently, excessive …
-
Polarized Photon Correlation Studies in Singly Positive Helium Ion + Helium Collisions
… consists of an ion source, differential pumping chamber and the collision chamber. Each of the sections will be discussed in the following paragraphs. A discussion of the vacuum is omitted from the description because high vacuum techniques are adequately described in the literature.
-
Reference intervals for the echocardiographic measurements of the right heart in African school children and adolescents
… diseases where the RV often serves as the main pumping chamber...
-
Investigation of Active Materials as Driving Elements in a Hydraulic-Hybrid Actuator
… at a high frequency to pressurize fluid in a pumping chamber. This paper presents a comparison of a piezostack, Terfenol-D, and Galfenol element as the driving material in a hybrid-hydraulic actuator. The performance of the actuator with the various driving elements is measured through …
-
New Frank-Starling based contractility and ventricular stiffness indices: clinically applicable alternative to Emax
… failure, depending on the failure mode of the pumping chamber. To assess the severity of systolic failure, there exist clinical indices that quantify chamber contractility, namely: ejection fraction, (dP/dt), Emax (related to the rate of pressure rise in the pumping chamber), and Emax (related …
-
Understanding Physical Activity from the Perspectives of Children with Complex Heart Defects, their Parents and their Cardiologists
… (25 female, 5 to 11 years of age) with a single pumping chamber in the heart were measured by accelerometry. Fitness and gross motor skill measures and medical history information were analyzed to identify factors associated with MVPA participation. Increased activity was related to the use of …
-
Η επίδραση της υποβοήθησης με παραορτική αντλία αντιώθησης (PULVAD) στους δείκτες συστολικής και διαστολικής λειτουργίας της αριστεράς κοιλίας σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας
… Methods: PULVAD comprises a pneumatically-driven pumping chamber implanted in the thoracic cavity and connected to the ascending aorta. PULVAD is ECG-synchronized and operates under the counterpulsation principle: deflation of the device air chamber just prior and during systole draws blood from …
-
MEMS-enabled drug delivery through wirelessly controlled pumping and valving actuation
… also has two actuators that enable simultaneous pumping and valving of the active drug release mechanism to meet the leakage challenge. An inductor-capacitor (LC) circuit patterned on a copper-clad polyimide sheet, using photolithography technique, acts as a wireless heat source. This LC circuit …
-
Muscle Contributions to Cardiac Function and Exercise Abilities in Patients with Fontan
… flow and a single designated ventricular pumping chamber. The final step of palliation, the Fontan, has become the namesake for this population of CHD patients. Despite improved survival, individuals with Fontan experience long-term sequelae that includes decreased exercise capacity. …
-
Studies in right ventricular function : employing the conductance catheter method for ventricular volume determination
… patients in whom the right ventricle is the only pumping chamber. <br/><br/>Twenty-five years ago Hiroyuki Suga described the active and passive properties of an isolated left ventricle as constants that relate pressure to volume during systole and diastole and proposed the model of "time-varying …
-
Piezohydraulic Actuator Design and Modeling Using a Lumped-Parameter Approach
… Inlet and outlet valves are connected to a pumping chamber where pressure is built by the displacement of the piezoelectric material and released by the opening of the outlet valve, thus achieving a variable flow rate that is used to push a hydraulic cylinder. Loads may be connected to this …
-
Comparative geomechanical investigation of empirical, analytical, and numerical methods utilized in designing flat-roof excavations in discontinuous and laminated rockmasses
… is then applied to a case study of the Bondi Pumping Chamber excavation in Sydney, New South Wales, Australia. The second objective of this thesis is to analyze roof self-supporting capacity and bolted stability through a parametric sensitivity analysis of 8,640 unique explicit DEM models of …
-
Methods for Identifying Acoustic Emissions From the Front Face of a Small Piezoelectric Blower
… ceramics is surfacing in the area of pumping and cooling. Air pumps that use these ceramics replace the traditional electric motor, resulting in lower power consumption, less moving parts, constant pressure gradients, lower overall weight, and a low profile. The current drawback of …