  1. Numerical analysis of punching failure in reinforced concrete structures

    … concrete slabs supported on columns fail by punching when a conical plug of concrete perforates the slab above the column. This failure has been mostly investigated experimentally, so what can numerical simulation contribute to understand this phenomenon? To answer this question, a …

    epfl Repository record for Numerical analysis of punching failure in reinforced concrete structures (opens in a new tab)

  2. Effective stiffness and punching failure of flat-plate structures

    … procedure is demonstrated through examples. Punching failure in a flat-plate structure greatly changes the overall stiffness and results in moment redistribution between various members of the structure. This effect needs to be considered in the nonlinear analysis of flat-plate structures …

    rice Repository record for Effective stiffness and punching failure of flat-plate structures (opens in a new tab)

  3. Punching failure and compressive membrane action in reinforced concrete slabs

    This study of punching failure and compressive membrane action in reinforced concrete slabs provides a basis for the development of a more realistic design approach for continuous slabs subjected to concentrated loadings.The results of an extensive series of tests on one quarter scale models of the …

    qu-belfast Repository record for Punching failure and compressive membrane action in reinforced concrete slabs (opens in a new tab)

  4. Evaluation, Modeling, and Retrofit of Flat-Slab Buildings subjected to Seismic Loading

    … developed to improve their seismic resistance. Punching failure at slab-column connections in non-ductile flat-slab buildings during earthquakes can trigger progressive collapse of floor slabs. Based on the test results of a large number of interior and exterior connections, a methodology is …

    rice Repository record for Evaluation, Modeling, and Retrofit of Flat-Slab Buildings subjected to Seismic Loading (opens in a new tab)

  5. Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings

    … accelerations. Flat-plate structure is prone to punching shear failure at slab-column connections which may lead to a catastrophic progressive collapse. Slabs of flat-plates functioning only as gravity system generally have a reinforcement ratio less than 1% for the tensile bars resisting …

    unlv Repository record for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab)

  6. Evaluation of punching shear strength design and modelling approaches for slab-column connections

    … role. Due to the sudden and brittle nature of punching shear failures, slab-column connection design must be conducted with proper safety precautions. The first part of this study aims to evaluate the safety level of different design expressions in the codes. Fir this purpose, the ability of …

    metu Repository record for Evaluation of punching shear strength design and modelling approaches for slab-column connections (opens in a new tab)

  7. Experimental and analytical evaluation of disproportionate collapse flat-plate buildings

    … portion of it. This progression can occur if the punching shear strength of the surrounding connections is not sufficient. In order to make the most accurate determination of the potential for disproportionate collapse of flat plate structures, this research seeks to accurately evaluation the …

    missouri Repository record for Experimental and analytical evaluation of disproportionate collapse flat-plate buildings (opens in a new tab)

  8. Investigation of Local Failure Mechanisms of Inverted-T Bent Caps and Strengthening Using CFRP Sheets

    … and analytical investigation on local failure mechanisms of inverted-T bent caps with emphasis on punching shear, strengthening ledge- and hanger-deficiencies with CFRP, and an analytical study on the impact of various reinforcement layouts on the local behavior of inverted-T bent caps. …

    tamu Repository record for Investigation of Local Failure Mechanisms of Inverted-T Bent Caps and Strengthening Using CFRP Sheets (opens in a new tab)

  9. Post-punching behavior of reinforced concrete slabs

    … deflection at the serviceability limit state and punching shear at the ultimate limit state. When no punching shear reinforcement is provided, failure develops in a brittle manner. Punching shear failure occurs with almost no warning signs, because deflections are small and cracks at the top side …

    epfl Repository record for Post-punching behavior of reinforced concrete slabs (opens in a new tab)

  10. INVESTIGATION OF PUNCHING SHEAR DESIGN APPROACHES IN TURKISH BUILDING EARTHQUAKE SPECIFICATION FOR INTERIOR SLAB-COLUMN CONNECTIONS

    … plate sytems are very critical due to possible punching failure at slab-column connections. Importance of having reliable design and guidelines on punching shear design of slab-column connections under lateral loads have been shown in the past for zones under high seismic risk. In the new …

    metu Repository record for INVESTIGATION OF PUNCHING SHEAR DESIGN APPROACHES IN TURKISH BUILDING EARTHQUAKE SPECIFICATION FOR INTERIOR SLAB-COLUMN CONNECTIONS (opens in a new tab)

  11. A critical review of the symmetric punching shear of reinforced concrete flat slabs.

    … composite bridge deck showed that the ultimate punching shear load depends on the shape of the loaded area, the compressive strength of concrete, the flexural reinforcement ratio and on the arrangement of steel bars. Punching failure follows the formation of an inclined failure surface from the …

    ottawa-retro Repository record for A critical review of the symmetric punching shear of reinforced concrete flat slabs. (opens in a new tab)

  12. Improvement of punching strength of flat plates by using carbon fiber reinforced polymer (CFRP) dowels

    … connection is found to be susceptible to punching failure that causes serious unrepairable damage leading to the collapse of the structures. The objective of this study is to enhance the punching shear strength of slab-column connections in existing deficient flat plate structures. For …

    metu Repository record for Improvement of punching strength of flat plates by using carbon fiber reinforced polymer (CFRP) dowels (opens in a new tab)

  13. Design, manufacture, testing and analysis of filament-wound hybrid FRP-concrete beam

    … to fail first to serve as a warning of imminent failure, but rather to enhance the stiffness of the beam by compensating for the lack of stiffness of the GFRP profile. The external filament winding ensures composite action between the concrete and the pultruded profile. The experimental results …

    unsw Repository record for Design, manufacture, testing and analysis of filament-wound hybrid FRP-concrete beam (opens in a new tab)

  14. Evaluation of tensile and compressive membrane action in isolated slab column specimen

    … susceptible to progressive collapse in which the failure of one slab-column connection can propagate to other connections and cause a full collapse of the building. The most common mechanism of failure in flat-plates is known as punching shear, when inclined shear cracks propagate through the …

    missouri Repository record for Evaluation of tensile and compressive membrane action in isolated slab column specimen (opens in a new tab)

  15. Punching Shear Retrofit Method Using Shear Bolts for Reinforced Concrete Slabs under Seismic Loading

    … this type of structures can be subject to punching-shear failure in the slab-column connections. Without shear reinforcement, the slab-column connection can undergo brittle punching failure, especially when the structure is subject to lateral loading in seismic zones. The shear bolts are a …

    waterloo Repository record for Punching Shear Retrofit Method Using Shear Bolts for Reinforced Concrete Slabs under Seismic Loading (opens in a new tab)

  16. Impact resistance of masonry walls : |b materials characterisation and numeric modelling.

    … impulse, base friction, fracture energy, joint failure stress and angle of dilatancy. The masonry specific interface model was also used to simulate the behaviour of reinforced walls. Results showed that the model was able to predict the correct failure mode and approximate peak displacement for …

    whiterose Repository record for Impact resistance of masonry walls : |b materials characterisation and numeric modelling. (opens in a new tab)

  17. Impact behaviour of hybrid GFRP-concrete beam under low-velocity impact loading

    … through the elastic-plastic deformation and failure mechanisms, such as matrix cracking and delamination. A numerical model was developed to analyse the development and propagation of the stress. The numerical investigation of the hybrid beam to static loading was conducted to validate the …

    unsw Repository record for Impact behaviour of hybrid GFRP-concrete beam under low-velocity impact loading (opens in a new tab)

  18. Progressive Collapse Analysis of Older Reinforced Concrete Flat Plate Buildings Using Macro Model

    … from slab to column, and to simulate connection punching shear failure. To ensure applicability of the proposed macro model, it is validated by 24 large-scale tests conducted on isolated slab-column connections under three different types of loading conditions. Both dynamic and static analyses …

    unlv Repository record for Progressive Collapse Analysis of Older Reinforced Concrete Flat Plate Buildings Using Macro Model (opens in a new tab)

  19. Seismic response of connections in indeterminate flat-slab subassemblies

    … structures to severe ground motion. The failure in such structures typically initiates at the slab-column connections in the form of a punching failure. This investigation was carried out to evaluate the adequacy of current procedures for the design of slab-column connections. The …

    rice Repository record for Seismic response of connections in indeterminate flat-slab subassemblies (opens in a new tab)

  20. Infill panel system for seismic strengthening of flat-plate buildings

    … motions of even low to moderate intensity. Failure in such structures is typically the result of punching failure at the slab-column connection. Because of this, performance-based retrofit procedures are needed to upgrade these non-ductile buildings. This investigation evaluated the use of …

    rice Repository record for Infill panel system for seismic strengthening of flat-plate buildings (opens in a new tab)