Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"push-out testing"”
-
MODELING AND TESTING OF THE INTERFACIAL STRESS STATE OF A 316L STAINLESS STEEL CLAD TUNGSTEN COMPOSITE USING PUSH-OUT TESTING
… that were sufficient for complete bonding without the formation of a second phase. Three forms of tungsten single crystal, wrought, and wrought/annealed and two diameters of the wrought were clad through HIPing at two different temperatures. Push-out testing, along with finite element modeling …
-
Experimental assessment of borehole plug stability
… strength is measured by means of a total of 37 push-out tests on concrete borehole seals emplaced in hollow cylinders of welded tuff. Lateral stress is applied to 17 rock cylinders during push-out testing. Results are presented of an extensive finite element analysis of the stress distribution …
-
Evaluation of a Press Fit, Percutaneous, Skeletally Anchored Endoprosthesis for Prosthetic Limb Attachment: Bone Response and the Effect of Low Intensity Vibration
… vibration would improve osseointegration without jeopardizing mechanical stability. To test this hypotheses a press fit, percutaneous endoprosthesis was successfully implemented in an ovine model to allow immediate weight bearing after the attachment of an exprosthesis. Animals were split into …
-
Interfacial modifications in fiber reinforced geopolymer matrix composites for improved toughness
… for processing of near net shape components without many of the complexities that would be associated with conventional ceramics or metals manufacturing technologies. To-date, fiber reinforced geopolymers have seen limited use, primarily in areas that emphasize high temperature resistance and …
-
Investigation of RC Columns Encased in UHPC Tubes Under Axial Load and Bending Including Assessments of Interfacial Bond and Tube Properties
… between UHPC and NSC is examined through push-out testing. Peak bond strength (τᵤ) was highly sensitive to temperature, surface texture, fiber type, and NSC compressive strength. Due to thermally induced pressure on the NSC core, τᵤ doubled at -20°C. Bubble-textured UHPC surfaces were …
-
Investigation of liner-host pipe strength and its influence on behaviour at ring fracture
… they can restore structural performance without conventional open-cut replacement. The structural response of a CIPP liner depends not only on its material and mechanical properties but also on its interaction with the host pipe, including shear stress transfer across the liner–host pipe …
-
The behaviour of ultra-high-performance concrete in precast concrete bridge deck connections
… experimental program consisted of shear pocket push-out testing and full-scale bridge deck testing. The main objective was to study the UHPC performance in the shear pocket and joint connections. All specimens were statically loaded until failure. The push-out test specimens consisted of two …
-
Optimization and Translation of MSC-Based Hyaluronic Acid Hydrogels for Cartilage Repair
… of cartilage to carry joint stresses and, without an innate regenerative response, often lead to degenerative changes towards the premature development of osteoarthritis. Surgical interventions have yet to restore long-term mechanical function. Towards this end, tissue engineering has been …
-
Improving bone and implant surface integration
… μm dicalcium phosphate dihydrate (DCPD) and without coating (TiPL); and grit blasted titanium implants with hydroxyapatite (HA) and without coating (TiGB). Implants were inserted into cancellous and cortical bones with gaps and fits in sheep hind limbs. One group of sheep was treated by dynamic …
-
Self-Fitting Craniomaxillofacial (CMF) Bone Scaffolds with Tunable Properties
… tissue integration, both histologically and by push-out testing, when compared to a PEEK implant. PCL-DA self-fitting scaffolds are limited by a slow degradation rate as well as a high transition temperature (Ttrans = Tm,PCL ~55 ºC) required for press-fitting. To accelerate degradation, a …
-
Calcium phosphate ceramic composites used for orthopedic implant applications
… white rabbits and evaluated using mechanical push-out testing, microradiography, and image analysis after 18 weeks of implantation. The interface shear strength values were found to be higher for the steel and steel/osteoceramic than for the osteoceramic (air and H fired) and …
-
Ultimate capacity evaluations and numerical analyses for shear connectors in steel composite girders with tall haunches
… are encountered. Additionally, there is little testing data related to composite systems involving tall haunches. Thus, TxDOT research project 0-7016 “Develop Guidance for Structural Behavior of Tall Haunches in TxDOT Beam and Girder Bridges” was conducted to investigate the behavior of shear …
-
Retrograde Ausdrückversuche am bovinen Femurkondylus zur Testung der Implantatverankerung spongiöser Konstrukte
Die Arbeit befasst sich mit der Suche nach einer idealen Verankerungsmöglichkeit spongiöser Konstrukte in der Femurkondyle adulter Rinder. <br>Ziel ist es für die spätere klinische Anwendung ein Verfahren zu erproben, daß eine stabile und doch technisch einfache Verankerung gewährleistet, um durch …
-
Enhancement and evaluation of PAN-derived carbon fibres and resulting composites by active screen plasma surface modification
Owing to their excellent properties, such as outstanding mechanical properties, high strength to weight ratio, high thermal stability and corrosion resistance, carbon fibres (CFs) have become materials of choice for the reinforcements of high-performance composites. However, their chemical …