Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"pycnometer"”.
-
Specific gravity determination of marine sediments
… of marine sediments. Application of the bottle pycnometer technique, the standard determination method, is time consuming, tedious, and perhaps subject to inaccuracies in the case of fine particulate matter. A review of methods currently in use was conducted to ascertain the present state of the …
-
Density and compressibility of superheated carbon tetrachloride
… technique. An apparatus, called a capillary pycnometer, was constructed which enabled extension of existing data on liquid densities into the superheated region. In brief, the apparatus consisted of a spherical quartz bulb attached to a long uniform section of capillary tubing in such manner …
-
The determination of ethanol in aqueous solution by gas-liquid partition chromatography
… and technique to perform. The dichromate (2), pycnometer and refractometer methods are three such methods. The interfering substances most often present in industrial and food products are fusel oils and acetaldehyde. These substances interfere in the three methods just mentioned. It is of …
-
Application of Magnetic Resonance Imaging for in vitro investigation of meniscus and cartilage degeneration in the knee
… wear quantification methods were validated using Pycnometer measurements. In addition, a novel approach was developed at 9.4T MRI to non-destructively investigate intrameniscal architecture and damage. Cartilage defect models were successfully created on the femoral condyle and tibia after …
-
Fracture Toughness Improvement of ����� Ceramics by Grain Size Control and Ductile Phase Reinforcement
… by the standard Archimedes method using a 5 mL pycnometer. Hardness values were determined by Vickers micro hardness indentations and the fracture toughness values were calculated from indentation dimensions and indentation-tip crack length measurements. Uncoated powders, coated powders, …
-
Polyurethenae foams and engineering education
… by a heat flow meter for [subscript], and a pycnometer for the foam density and closed cell content. Besides, heat capacities (𝐶𝑃) of most common polyols and isocyanate in making PU foams were experimentally measured. Then a general formula was created for using in a Matlab code to boost …
-
The Effect of Coating Parameters On Advanced TRISO Fuels With Zirconium Carbide
… measurements are performed using a helium pycnometer to ensure coating densities meet or exceed 95% theoretical density.</p>
-
Effect of zinc substitution on the structure of calcium Fluoro-Alumino-Silicate glasses and glass-ceramics
… The new glasses were characterized by Helium Pycnometer, DSC, TGA, FTIR, Raman, ESEM and EDX. The density of the resulting glass ceramics was measured also by Helium pycnometer and X-ray diffraction was conducted to identify the crystal phases formed. The density of zinc substituted glasses …
-
Dulkio kiekio įtaka vidinės trinties kampo vertėms smėliuose /
… were tested for grain size distribution, pycnometer analysis, proctor compaction and liquid and plastic limit determination. To determine the internal friction angle values, direct shear tests were conducted. This method was applied to mixtures under two conditions: 1. Loose state (ID = …
-
The effect of boron substitution on the structure of calcium-aluminosilicate calcium-fluoro-aluminosilicate glasses and glass-ceramics
… a combination of analytical tools like helium pycnometer, FTIR, Raman, XRD, multinuclear MAS-NMR spectroscopy and thermal analysis by DSC and TGA. The morphology of the crystal phases was observed by ESEM, and the identification of the composition observed was achieved by EDX. The density of …
-
Desenvolvimento de pastas leves utilizando microesferas ocas de cerâmica para aplicação em cimentação de poços petrolíferos
… ceramic microspheres were characterized by pycnometer, granulometric analysis, XRD, and XRF to determine their class according to ASTMC618−12A. The slurry designs were formulated with specific masses between 11.5 lb/gal and 12.5 lb/gal. The tests were carried out using the practical …
-
Estudo do aproveitamento de resíduo de gesso como carga para compósito com matriz de resina expansiva de mamona
… the percentage of open pore volume using a gas pycnometer, scanning electronic microscopy (SEM), in addition to testing of flammability and the resistance to contact with hot surfaces. Through the analysis of the results, it appears that it is possible to produce a new material, which few …
-
Effect of powder shape and size on the properties of low- viscosity iron-based feedstock used in low-pressure powder injection molding
… binders, and feedstock were measured using a gas pycnometer. The melting point of the feedstocks and the binders' burnout temperatures were obtained using differential scanning calorimetry tests (DSC) and thermogravimetric analysis (TGA), respectively. The density of sintered specimens was …
-
A Detailed Study of the Physical Properties of Recently Deposited Sediments from a Minibasin, Northwest Gulf of Mexico
… core logger, miniature vane, fall cone, pycnometer, coulometer and X-ray fluorescence scanner, in a very high sampling resolution, to obtain profiles able to represent accurately the variation of the properties with depth. We compared values of the same property obtained by independent …
-
INVESTIGATION OF LONG TERM PILLAR STABILITY IN AN ABANDONED GYPSUM MINE BASED ON DISSOLUTION MODELS
… this transformation occurred using a helium pycnometer and determined that 80 °C can be used for gypsum’s moisture content measurements. The saturation process of specimens for mechanical testing was also investigated, concluding a saturated gypsum-water solution is required to minimize …
-
DETERMINATION OF BULK DENSITY OF ROCK CORE USING STANDARD INDUSTRY METHODS
… were determined using an automated helium gas pycnometer, which is considered an industry standard. The saturated-surface-dry density used in the aggregate industry is outlined in ASTM C127-07 (Standard Test Method for Density, Relative Density (Specific Gravity), and Absorption of Coarse …
-
Petrography, physical properties, and geotechnical behavior of modern sediments, Southern Chile Trench
… size analysis, Multi-Sensor-Core-Logging (MSCL), pycnometer measurements, RDanalysis, <br>and SEM investigation. Sediment strength and frictional properties were determined by triaxial testing, high-strain ring shear testing, and direct shear testing. The sample strategy arranged for a preferably …
-
Mechanical Evaluation of Mandibular Defects Restored with rhBMP-2: A Finite Element Model
… Density of the 10 samples was determined with a pycnometer. A 2-dimensional model of the mandible was virtually created to simulate the mandible for a given BMP/carrier group. Subdomains of the model included cortical bone, regenerated bone, periodontal ligament, enamel, and cementum. Boundary …
-
Thermal characterization of magnesium containing ionomer glasses
… The new glasses were characterised by Helium Pycnometer, FTIR, DSC and XRD. The optimum nucleation temperatures and activation energies were calculated by DSC, the crystal size was measured using the Sherrer equation from the XRD patterns and finally the chemical structure was analysed by …
-
Microstructural and fluid transport properties of potatoes during frying
… images followed trends similar to Soxtec and Pycnometer methods, respectively. Image analysis showed a significant change in pore size distribution as a function of frying time. Frying time was also observed to have an effect on tortuosity, which is an important microstructural transport …
Page 1 of 2