High Temperature Gas Kinetic Study of Nitrous-Oxide Decomposition Performed With a Shock Tube and Quadrupole Mass-Filter
Made available in DSpace on 2014-12-09T17:35:17Z (GMT). No. of bitstreams: 1 6511792.pdf: 3105531 bytes, checksum: d9c7321d5a643b4c21d0b16420e09436 (MD5) Previous issue date: 1965
-
High Temperature Gas Kinetic Study of Carbonyl Sulfide Decomposition Performed With a Shock Tube and Quadrupole Mass-Filter
Made available in DSpace on 2014-12-09T17:35:33Z (GMT). No. of bitstreams: 1 6612346.pdf: 3906751 bytes, checksum: d80bd2d209abc6e551ef7a62a26c450c (MD5) Previous issue date: 1966
-
Quadrupole Mass Filter as a Sensitive and Selective Detector for Direct Gas Chromatographic Coupling Employing a High Capacity Sampling System
Made available in DSpace on 2014-12-10T23:01:19Z (GMT). No. of bitstreams: 1 7212351.pdf: 3151744 bytes, checksum: 5ca90d716381b539aa9e099be893f8e3 (MD5) Previous issue date: 1971
-
Ion-molecule reactions in mixtures of methane and carbon dioxide
Using a quadrupole mass filter, ion-molecule reactions in mixtures of methane and carbon dioxide were investigated at pressures of 0.1-0.4 torn. Rate constants for several of the reactions were determined and it was found necessary to use ionic mobilities to calculate the appropriate residence …
-
Mass selected low energy ion-assisted growth of epitaxial GaN thin films: Impact of the nitrogen ion species
In this thesis, a custom quadrupole mass filter setup was established to independently investigate the impact of the most prominent ion species that are present during ion-assisted deposition. The setup was applied to the low temperature epitaxial growth of GaN thin films on 6H-SiC substrates. …
-
The Detection of Negative Ions and Their Stabilities
… was given of the construction and operation of a quadrupole mass filter system. This was used to identify negative ions emitted from a hot polycrystalline tantalum surface. The ionisation of various interhalogens and cyanogen halides were studied using the mass filter system. The kinetic methods …
-
A linear Paul trap for barium tagging of neutrinoless double beta decay in nEXO
… its own anti-particle and determine the absolute mass scale of the neutrinos. nEXO's sensitivity is limited by the background level. Barium tagging is the ultimate background rejection method using the coincidence detection of ¹³⁶Ba as the daughter nucleus. A linear Paul trap (LPT) is needed for …
-
Fundamental Investigations of the Quadrupole Ion Storage trap Operating in Novel Modes
The Quadrupole Ion Store (Quistor) is a device which traps charged particles in an electric field composed only of radio - frequency (RF) and DC voltage components. The Quistor therefore operates on very similar principles to the Quadrupole Mass Filter, but has not been developed to the same …
-
Development of methods based on ICP-mass spectrometry for the determination, speciation and isotopic analysis of metals and oxy-anions in an environmental context
… techniques, ranging from single-collector quadrupole mass filter units (ICP-QMS) to single-collector and multi-collector sector-field based ICP-MS instruments with high mass resolution capabilities. The versatility of ICP-MS units as (i) environmental regulatory monitoring tool for the …
-
A Study of the Quadrupole Ion Storage Source
Although the three-dimensional quadrupole ion trap has received some attention as a mass spectrometer, few reports have been published describing the more general exploitation of its ion storage capabilities« This latter aspect is the subject of the present research. Initially the general features …
-
Trapping biomolecular ions in superfluid helium droplets
… is combined with an electrospray ion source, a quadrupole mass filter, and a linear hexapod ion trap in which mass-to-charge selected gas-phase biomolecular ions are accumulated. The trap then serves as a pickup cell for He droplets that pass through the trap and pick up the species of interest, …
-
INVESTIGATIONS OF THE RF-ONLY QUADRUPOLE MASS ANALYZER.
The performance of a quadrupole mass filter operated in the RF-only mode has been investigated. A discussion of both the formal and qualitative theories of quadrupole mass analyzers is given. Data is presented which demonstrates that the transmission properties of such devices deviate markedly from …
-
A Study of the Stabilities of Negative Ions
… rise to similar numbers of ions of differing mass, could have been misinterpreted in terms of a simple reaction. To overcome this, a surface ionization source was attached to an Atlas AMP 3 Quadrupole Mass Filter, which enabled direct identification of the ions to be made along with the usual …
-
Computational Mass Spectrometry
<p>Conventional mass spectrometry sensing has isomorphic nature, which means measure the input mass spectrum abundance function by a resemble of delta function to avoid ambiguity. However, the delta function nature of traditional mass spectrometry sensing approach imposes trade-offs between mass …
-
SOME PROBLEMS CONCERNING THE MIGRATION AND DISTRIBUTION OF HELIUM-4 AND RADON-222 IN THE UPPER SEDIMENTS OF THE CRUST - A THEORETICAL MODEL; AND THE DEVELOPMENT OF A QUADRUPOLE ION FILTER FOR MEASURING HELIUM AT THE SOIL-AIR INTERFACE
… for its measurement. The development of a quadrupole mass filter especially designed to monitor helium at the soil-air interface is described. Preliminary laboratory tests using author's prepared helium standards with several concentrations down to 12 ppm are also reported.
-
Development of Proton-transfer reaction mass spectrometry techniques
… and application of trace gas detectors based on mass spectrometers. To be more specific, products of chemical reactions of trace gas molecules with H3O+ ions are studied. This experimental technique is called Proton-Transfer Reaction Mass Spectrometry (PTR-MS). The nature of the proton-transfer …
-
High resolution electron impact studies
… 127° electrostatic electron velocity selector to filter the electron beam. An electron energy analyzer permitted the observation of inelastically scattered electrons, and a monopole or a quadrupole mass filter permitted the measurement of the relative amounts of positive or negative ionization …
-
Quadrupole mass filters operated in higher stability regions
… and theoretical studies of the properties of a quadrupole mass filter operated in the fourth stability region (Mathieu parameters a≈0 and q≈21.3) and the sixth stability region (Mathieu parameters a≈8, q≈6). The experimental work is done with a thermal ionization quadrupole mass spectrometer. …
-
Crossed molecular beam: I. Photoionization studies of hydrogen sulfide and its dimer and trimer, II. A rotating source crossed molecular beam apparatus
… which contains the electron bombardment ionizer, quadrupole mass filter, and ion counting system which constitute the detector. This stationary detector chamber permits strong differential pumping in all regions and allows the entire detector to be translated, in vacuo over a distance of (TURN)60 …
-
An Electrospray Ion Source for Ultra-High Vacuum Deposition of Organic Molecules
… these stages and ensure its purification. A quadrupole deflector separates the ions from neutral contaminations, originating from the ion source, and confines the ions’ kinetic energy. A quadrupole mass filter is used for mass selection during the deposition process. One main focus of the …
Page 1 of 2