Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"quadrupole trap."”.

  1. QUADRUPOLE LEVITATION OF PARTICLES IN A THERMODYNAMICALLY REALISTIC CLOUD ENVIRONMENT

    … conditions. Keeping this objective in mind, a quadrupole trap with thermodynamic control has been designed and constructed in order to create an environment conducive to studying clouds in the laboratory. The quadrupole trap allows a single cloud particle to be suspended for long times. The …

    mtu Repository record for QUADRUPOLE LEVITATION OF PARTICLES IN A THERMODYNAMICALLY REALISTIC CLOUD ENVIRONMENT (opens in a new tab)

  2. Ion Photon Entanglement in a Parabolic Mirror Trap

    Single trapped ion qubits are excellent candidates for quantum computation and information, and they also possess the ability to coherently couple to single photons. Efficient fluorescence collection is the most challenging part in remotely entangled ion qubit state generation. To address this …

    washington Repository record for Ion Photon Entanglement in a Parabolic Mirror Trap (opens in a new tab)

  3. Progress towards a quantum simulator with cold atoms

    … calculation for atoms held in a magnetic quadrupole trap was developed and tested, giving similar calculation of temperature as the commonly known time of flight (TOF) method. It is shown that this new method gives better results than the common TOF method for short time of flight. …

    birmingham Repository record for Progress towards a quantum simulator with cold atoms (opens in a new tab)

  4. Spectroscopic measurement of the absorption and scattering properties of single aerosol particles

    … spectroscopy (CRDS) with a linear electrodynamic quadrupole trap, that allows the first direct spectroscopic quantification of the evolving extinction cross-sections of single, light-absorbing aerosol particles as their size and composition change. The evolving real and imaginary components of the …

    bristol Repository record for Spectroscopic measurement of the absorption and scattering properties of single aerosol particles (opens in a new tab)

  5. Design and construction of a device for light scattering studies on airborne particles

    … the charged particle for the purpose of particle trapping is illustrated. The most common systems like the two or four ring electrodynamic balance and the quadrupole trap are pointed out. In Chapter 4 a short review of the possibility of using scattered light to study aerosol particles is …

    wurz-thes Repository record for Design and construction of a device for light scattering studies on airborne particles (opens in a new tab)

  6. Development and characterization of a 171Yb+ miniature ion trap frequency standard

    … ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed, getter-pumped vacuum package, and interrogated on the 12.6 GHz hyperfine transition. We hope to achieve a long-term fractional frequency stability of 10^−14 with this miniature clock while consuming …

    unm Repository record for Development and characterization of a 171Yb+ miniature ion trap frequency standard (opens in a new tab)

  7. Experiments with laser cooling and cold spinor gases

    … capture of Er atoms into a 2D magneto-optical trap (2D MOT). Together, the induction oven and 2D MOT constitute a novel, compact source of cold Er atoms. Additionally, the construction and characterization of high current magnetic field coils for a magnetic quadrupole trap (MQT) and Helmholtz …

    maryland Repository record for Experiments with laser cooling and cold spinor gases (opens in a new tab)

  8. Chemical differences of atherosclerotic plaques in native and bypass human coronary arteries and diseased and non-diseased human aortas

    … MS/MS) of the digested peptides with a linear quadrupole trap Fourier transform ion cyclotron resonance mass spectrometer was used to determine the amino acid sequences. Protein extracts of normal and diseased aortas and native and bypass arteries were analyzed using differential gel …

    lsu-thes Repository record for Chemical differences of atherosclerotic plaques in native and bypass human coronary arteries and diseased and non-diseased human aortas (opens in a new tab)

  9. Novel Ion Trap Made Using Lithographically Patterned Plates

    A new approach of making ion trap mass analyzers was developed in which trapping fields are created in the space between two ceramic plates. Based on microfabrication technology, a series of independently-adjustable electrode rings is lithographically patterned on the facing surfaces of each …

    byu Repository record for Novel Ion Trap Made Using Lithographically Patterned Plates (opens in a new tab)

  10. A new apparatus to simulate fundamental interactions with ultracold atoms

    … the two miscible components |F = ±1⟩ if trapped by a spin-independent potential, avoiding the known phenomenon of â€TMbuoyancyâ€TM. Studying the dynamics of such systems for sufficiently long times, with a mixture subject to Zeeman differential energy shifts, requires a specific effort …

    trento Repository record for A new apparatus to simulate fundamental interactions with ultracold atoms (opens in a new tab)

  11. Towards cold state-selected ion-molecule reactions

    … now exist. In particular, the generation of trapped molecular ions at mK temperatures has been achieved by sympathetic-cooling with laser-cooled atomic ions. By implementing schemes to selectively prepare and control the internal quantum state of molecular ions, and developing detection …

    oxford Repository record for Towards cold state-selected ion-molecule reactions (opens in a new tab)

  12. Laboruntersuchungen zum Gefrierprozeß in polaren stratosphärischen Wolken

    Bei der polaren stratosphärischen Ozonzerstörung spielen heterogene chemische Reaktionen eine zentrale Rolle. Dabei werden sonst relativ inerte Verbindungen auf den Wolkenteilchen katalysiert. Die Rate solcher Reaktionen ist davon abhängig, ob die Wolken aus flüssigen oder gefrorenen Tropfen …

    fu-berlin Repository record for Laboruntersuchungen zum Gefrierprozeß in polaren stratosphärischen Wolken (opens in a new tab)

  13. Präzisionsmassebestimmung einzelner Partikel im Femtogrammbereich und Anwendungen in der Oberflächenphysik

    … method combines the well-known electrodynamic quadrupole ion trap in a UHV-chamber and fourier transformation of scattered light. The achieved mass resolution of down to $10^{-4}$ at 100 fg mass on a time scale of ten seconds allows a resolution of a few percent of the mass of an adsorbed …

    qucosa-diss Repository record for Präzisionsmassebestimmung einzelner Partikel im Femtogrammbereich und Anwendungen in der Oberflächenphysik (opens in a new tab)