Development of methods to evaluate the performance of snowboard wrist protectors
… aim of this project was to develop mechanical test methods to evaluate the protective characteristics of snowboarding wrist protectors. Two new mechanical tests and accompanying surrogates were developed to characterise snowboarding wrist protectors. A quasi-static test to measure the …
-
Highly Stretchable Miniature Strain Sensor for Large Dynamic Strain Measurement
… linearity and a fast frequency response under quasi-static test, the delay time for high strain rate test is just 30 μs. This stretchable strain sensor is also able to exhibit much higher sensitivities, with a gauge factor of as high as 80, than conventional foil strain gauges.
-
Identification of rotordynamic forces in a flexible rotor system using magnetic bearings
… of an annular gas seal on a flexiblerotor test rig. Dynamic loads are applied by magnetic bearings (MBs) that support the rotor. MB forces are measured using fiber-optic strain gauges that are bonded to the poles of the MBs. In addition to force and position measurements, a finite element …
-
Evaluation of seismic performance of a pre-cast concrete block arch system through testing and numerical modeling
… behavior using a combination of experimental testing and numerical modeling. Several small scale unreinforced and reinforced arch models were subjected to quasi-static and dynamic testing. For the dynamic testing, a suite of earthquake records was selected of varying magnitudes, types and …
-
Experimental Investigation and Numerical Simulation of an Unreinforced Masonry Structure with Flexible Diaphragms
… of URM structures were investigated via a quasi-static test of a full-scale two-story URM building and associated analytical and numerical studies. The tests of the 24ft. by 24ft. in plan 22ft. high URM building revealed that the damage was characterized by (1) the formation of large …
-
A Study on the Dynamic Characterization of a Tunable Magneto-Rheological Fluid-Elastic Mount in Squeeze Mode Vibration
This research undertakes the task of static and dynamic characterization for a squeeze mode Magneto-Rheological (MR) Fluid-Elastic mount. MR fluid's variable viscosity rate is advantageously used to develop a mount capable of mitigating input vibrations of varying magnitudes and frequencies …
-
An experimental study on the seismic interaction of flexible conductors with electrical substation equipment
… This was done by performing various experimental tests on one of the most commonly used configurations of flexible conductors in substations throughout the province of British Columbia in Canada. The experiments included a quasi-static test on the full-scale flexible conductor and four series of …
-
New Fatigue Test Method for Evaluating the Performance of Adhesive Bonded Joints
… selection is still often based upon simple quasi-static test results, determined at room temperature. This is generally a consequence of the complexity of fatigue behaviour and associated difficulty in reproducing expected service stresses and exposure conditions. Indeed, most parameters are …
-
Multiaxial fatigue characterization of self-reinforced polylactic acid-calcium phosphate composite
… pre-pregging technique has been investigated. Quasi-static test results indicated that PLA-PLA-TCP is stronger in tension than in compression and torsion and is significantly influence by moulding temperature. Uniaxial fatigue testing at 37° C in saline solution established S-N (Wöhler) curves …
-
Effects of Running Speed, Fatigue, and Bracing on Motor Control of Chronically Unstable Ankles
… of instability and repeated sprain injuries. Quasi-static test methods indicate poor postural stability and joint position sense (JPS) as associated motor control deficits. Little research, though, has investigated ankle motor control under dynamic (simulated sport) or fatigue conditions. To …
-
Seismic performance of Composite Plate Shear Walls
… is first validated using the results from a quasi-static test. The study describes details of the validation of the finite element model by comparing the results from quasi-static experimental program with finite element analysis results. Excellent correlation between the test results and the …
-
Interrogating the Configuration Space of Slender Structures
… disturbances. As demonstrated in this work, this testing can often be done non-destructively, allowing for subcritical testing and analysis while still providing a great deal of information on the system.</p><p>The chapters of this dissertation are ordered in a sequential manner of the complexity …
-
Reducing Earthquake-Induced Damage to Precast Concrete Bridge Piers
… regions of rocking precast piers. Large-scale test results demonstrated that UHPC is able to control seismic damage near the rocking plane, even without any mild-reinforcement. To address post-tension loss, tests were performed on strand-anchorage assemblies under cyclic load and an analytical …
-
Quasi-Static and Creep Behavior of Enhanced SIC/SIC Ceramic Matrix Composites
… behavior of the material at high temperatures. A quasi-static test was conducted at 1200 °C to determine the unloading response of the material. The stress-strain response of the composite demonstrates a hysterisis loop and a small amount of permanent strain, which are characteristic of the CMC's …
-
The Effects of Elevated Temperature and Laminating on the Quasi-Static and Fatigue Properties of Electrical Steel
… exposing it to higher temperatures on both the quasi-static and fatigue properties. An electric motor can reach high temperatures under a heavy load, and it is important to understand the combined effect of temperature and load on the electrical steel’s performance to ensure the durability and …
-
Primary Resonance Behavior of Expanded Polymer Cushion Material Under Low-Intensity Harmonic Excitations
… are experimentally identified through the use of static and quasi-static test results. Three different solution techniques are applied, free and forced vibration solutions derived, and used to study the behavior of an idealized packaging system containing Nova Chemicals' Arcel foam. Each solution …
-
Shake table testing and performance evaluation of a post-seismic repaired and retrofitted Oak Street Bridge bent with fibreglass wrapping system
… (denoted OSB-O) had been severely damaged when tested on the shake table at the University of British Columbia Earthquake Lab (E. Davey, 1996). During testing the structure's overall behavior was brittle, and little plastic deformation was observed before sudden shear damage occurred in the cap …
-
BLAST DAMAGE MITIGATION IN SUBMERGED SYSTEMS. PHASE I: INTERNAL EXPLOSION
… cold-formed steel sandwich panels under both quasi-static loads and confined explosions, where a total of fifty-seven sandwich panels were tested, considering various core configurations, different core sheet thickness, and different blast load intensity levels. The American ASCE/SEI 59-11 and …
-
Mechanical behavior of multifunctional and self - healing polymers and composites
… retardants POSS compounds, numerous mechanical tests have been performed, namely several types of quasi-static test and specifically tension, compression, three-point bending, GIC fracture toughness as well as dynamic tests of fatigue and CAI. Furthermore, a multi-scale model simulating the …
-
Vliv rychlosti deformace na mechanické chování 3D tištěných polymerů
… polymerů, konkrétně materiálů PLA a ASA. Pro testování jsou navrženy a vyrobeny ploché zkušební vzorky technologií 3D tisku s orientací vrstev 0° a 90° vůči směru zatěžování. Mechanické vlastnosti jsou hodnoceny na základě kvazistatických zkoušek na univerzálním trhacím stroji a dynamických …
Page 1 of 2