Quasi-static testing of cantilever masonry shear wall segments
… masonry shear walls, and were tested under quasi-static in-plane reversed cyclic loads. The specimens exhibited predominantly flexural behavior, as expected. Specimens exhibited high displacement ductility (5.6 to 16.7), as expected for flexure-dominated specimens. Specimens constructed with …
-
Experimental investigation of steel-to-timber joints with inclined self-tapping screws: A parametric study evaluating load-displacement behavior and testing configurations in quasi-static testing
Detta examensarbete undersöker användningen av lutande självgängande träskruvar i stål/trä-förband och behandlar deras design samt last-deformationsbeteende genom en experimentell undersökning och en litteraturstudie.Litteraturstudien ger en förståelse för dimensioneringen och beteendet hos …
-
Long Term Loading and Additional Material Properties of Vectran Fabric for Inflatable Structure Applications
… structure is composed. This thesis presents both testing methodology and results for a number of key properties using woven fabric constructed of Vectran fibers.;The primary source for test standards was the American Society for Testing and Materials (ASTM). Some alterations were made to standards …
-
A Computational Analysis of Marine Fenders Under Heavy Weather Mooring Conditions
… fenders are modeled as idealized springs, with static- load derived spring constants from manufacturer charts. This has been adequate for previous warships, however with more susceptible warships, a better understanding of the fenders reaction is required. Two series of tests were created, a …
-
Terfenol-D Carbon Fiber Reinforced Polymer (CFRP) Embedded Sensing for Early Damage Detection
… material's ultimate tensile strength (UTS). For quasi-static testing procedure of specimen 5714 (15 wt.% Terfenol-D embedded CFRP) on a 0-40% loading interval of the material's UTS, there was an observed localized (32 mm2 field of view) magnetic flux gradient of more than 5 mT (4%) with a …
-
Variable Recruitment in Bundles of Miniature Pneumatic Artificial Muscles and Space Qualified Pneumatic Artificial Muscles
… the actuator. Additionally, the fabrication and quasi-static testing results for PAMs assembled from candidate space qualified bladder and braided sleeve materials for use in space robotics are assessed.
-
Structural performance evaluation and optimization through cyber-physical systems using substructure real-time hybrid simulation
… are often driven by experiments. Experimental testing not only enables the prediction of structural responses under those dynamic loads but also provide a reliable way to investigate new solutions for hazard mitigation. Common experimental techniques in structural engineering include …
-
Extending the annular in-plane torsional shear test specimen to applications at high strain rates
… been used for material characterisation in the quasi-static regime. The aim of this research was to conduct further quasi-static testing using the in-plane torsion test and to extend its use into the dynamic regime. Quasi-static tests were performed on a quasi-static torsional (QST) system that …
-
Parametric impact characterisation of a solid sports ball, WITH a view to developing a standard core for the GAA Sliotar
… results demonstrated limited applicability of quasi-static testing and springtheory equations. Analysis of ball deformation behaviour demonstrated that centre-of mass displacement and diameter compression values were not consistently equivalent for all ball types. The contribution of …
-
Development of Methods to Evaluate Dynamic Fracture Toughness of Metallic Materials at Very High Loading Rates Under Limited Plastic Deformation Conditions
… availability of recent machines capable of testing at high strain rates when compared with testing at quasi-static strain rates. The quasi-static testing procedure has been well-established with different international standards. Still, the dynamic testing procedures are very limited as they …
-
Seismic Assessment of Out-of-Plane Loaded Unreinforced Masonry Walls
… and lateral resistance. A comprehensive quasi-static testing programme was developed by subjecting full-scale two-leaf and three-leaf URM walls to out-of-plane uniform forces. The objective of the tests was to develop an idealised predictive model for the out-of-plane behaviour of URM …
-
Innovative spring & piston based self-centering bracing systems for enhanced seismic performance of buildings
… when both systems are subjected to qualifying quasi-static loading. Strain rate effect was also assessed experimentally, and comparable results were achieved without any performance degradation. Numerical simulation shows excellent matching with the test results. Twelve reference braced steel …
-
Experimental evaluation of laminated glass interlayer under high strain rates
… laminated glass sheets using impact drop-weight testing. Virgin PVB as well as UVEKOL-S sheets extracted from laminated glass panels will evaluated in this study. The results of this study are expected to enhance the engineering design methods and numerical modeling of laminated glass windows …
-
Biomechanical Testing on Cadaveric Spines for Different Treatments that Affect Lumbar Stability
… through in vitro dynamic (±8Nm at 0.125Hz) and quasi-static (±7.5Nm at 0.1Hz) biomechanical tests, for flexion, extension, bending and rotation motions. Six FSUs where disarticulated from four human cadaveric lumbar spines (63 ± 12 years) and were tested under the following sequence: (1) intact, …
-
Experimental Methods for Understanding the Performance of Impulsively Loaded Cross-Laminated Timber Panels
… This research bridges the gap between the quasi-static and high strain rate loading regimes by investigating two areas that have remained unstudied or elusive, i.e., rolling shear failure of CLT under impulsive, blast-like loading and intermediate strain rates in CLT. A novel center-point …
-
Experimental and numerical investigation of triggered composite energy absorbing structures
… solver PAM-CRASH. The test program included quasi-static testing carried at UNSW and at the Defence Science and Technology Organisation in Australia, and dynamic testing at the DLR laboratories in Stuttgart. Finally a large scale test article was manufactured by the CRC-ACS and the thesis …
-
Achieving variable load crushing using pressurised composite tubes to improve vehicle crashworthiness
… levels. The experimental program included quasi-static testing carried out at UNSW in Australia and dynamic testing at the German Aerospace Centre (DLR) in Stuttgart, Germany. For dynamic testing, a new generation of crushing system was developed and tested. The contribution of the force …
-
Enviro-Mechanical Durability of Graphite/Epoxy Composite Materials
… these effects. Results from thermal analysis and quasi-static testing on neat resin and unidirectional laminates as a function of temperature and moisture are presented which provide insight into how material properties vary with temperature and moisture and form the inputs necessary to evaluate …
-
A performance-based loading protocol : generated sequential ground motion
… seismic design and experimental testing of structures, proving the need for a new loading protocol. GSGM is a ground motion fabricated from segments of real recorded ground motions that enables the introduction of performance-based seismic assessment and design to experimental …
-
Fatigue of Aluminum Gas Metal Arc Welds in Electric Vehicle Battery Pack
… This research performed component level testing of 2.3 mm AA-6061-T6 mating plates in the tee joint and lap configurations under quasi static and cyclic loading conditions. The quasi-static testing revealed the influence of porosity on the maximum load before rupture of lap shear joints, …