  1. Temperature control strategies for radiant floor heating systems

    A dynamic model of a radiant floor heating (RFH) system useful for control analysis is developed. The overall model consists of a boiler, an embedded tube floor slab and building enclosure. The overall model was described by nonlinear differential equations, which were solved using finite numerical …

    concordia Download PDF for Temperature control strategies for radiant floor heating systems (opens in a new tab)

  2. Radiant floor cooling systems - A measurement and simulation study

    Radiant floor cooling systems have been around for quite some time now, but are not extensively used or much talked about in the industry. The background for this thesis lies in a question formulated by a HVAC – consultancy firm, wanting to know if the radiant floor cooling system they had …

    chalmers Repository record for Radiant floor cooling systems - A measurement and simulation study (opens in a new tab)

  3. Modeling and control strategies for radiant floor heating systems

    A dynamic model of a radiant floor heating (RFH) system which predicts the dynamic response of RFH system has been developed. The overall model consists of a boiler, an embedded tube floor slab and building enclosure. The overall model was described by nonlinear differential equations, which were …

    concordia Download PDF for Modeling and control strategies for radiant floor heating systems (opens in a new tab)

  4. User experience aspects of radiant floor heating, Considerations for supporting users mental models

    … has been to explore the domain of residential floor heating thermostats and their users, in order to create a better user experience by supporting users’ mental models of floor heating systems. The thesis has resulted in 7 design considerations that aims to support manufacturers during their …

    chalmers Repository record for User experience aspects of radiant floor heating, Considerations for supporting users mental models (opens in a new tab)

  5. Development and Demonstration of a Performance Test Protocol For Radiant Floor Heating Systems

    The Radiant Heating markets - especially, the hydronic segment - are growing rapidly in North America due to homeowners' increasing demand for comfort and the steady rise in residential construction. Radiant systems are promising technologies for energy saving in commercial and residential building …

    vt Repository record for Development and Demonstration of a Performance Test Protocol For Radiant Floor Heating Systems (opens in a new tab)

  6. Experiments Designed to Evaluate Insulating Schemes for Slab-on-Grade Hydronic Radiant Floor Heating

    … insulating design practices for Hydronic Radiant Floor Heating (HRFH) vary anywhere from using only vertical insulation completely along the outdoor perimeter, complete vertical insulation and under-floor insulation a short distance in from the outdoor perimeter, and complete vertical and …

    sdstate Repository record for Experiments Designed to Evaluate Insulating Schemes for Slab-on-Grade Hydronic Radiant Floor Heating (opens in a new tab)

  7. Collection and Storage of Solar Gains Incident on a Radiant Floor in Highly Glazed Houses

    … rooms, even in the winter. Cooling of the floors may provide a means to prevent overheating in such a situation. Cooling a floor prevents the portion of solar gains absorbed by the floor to be transferred to the space by convection or infrared radiation. This cooling can be achieved with …

    carleton Repository record for Collection and Storage of Solar Gains Incident on a Radiant Floor in Highly Glazed Houses (opens in a new tab)

  8. Methodology for the Design and Predictive Control of Active Solar Windows with Radiant Floor Heating in Perimeter Zones

    … and controlling energy-positive facades with radiant floor heating in perimeter zones of commercial buildings. The model integrates bifacial semi-transparent photovoltaic windows, motorized venetian blinds, and hydronic radiant floor heating systems. These components are modeled to optimize …

    concordia Download PDF for Methodology for the Design and Predictive Control of Active Solar Windows with Radiant Floor Heating in Perimeter Zones (opens in a new tab)

  9. An Investigation of the Comparative Effects of Several Fill Materials on Heat Losses in the Ground from a Radiant Floor Panel

    … of a small test cubicle heated by means of a radiant floor panel when the fill material under the floor slab consisted of either crushed stone, pumice aggregate, or dry-compacted soil.

    unm Repository record for An Investigation of the Comparative Effects of Several Fill Materials on Heat Losses in the Ground from a Radiant Floor Panel (opens in a new tab)

  10. Dynamic modeling, control and energy simulation of a solar-assisted hydronic space heating system in a multi-function building

    … a water storage tank, baseboard heaters and a radiant floor heating system. The model consists of nonlinear differential equations which were programmed and solved using the MATLAB software. Two control strategies have been explored to compare the system performance: (i) a conventional PI …

    concordia Download PDF for Dynamic modeling, control and energy simulation of a solar-assisted hydronic space heating system in a multi-function building (opens in a new tab)

  11. A Study of Predictive Control Strategies for Optimally Designed Solar Homes

    … heat pump, a thermal energy storage tank and a radiant floor heating system in a thermally massive concrete slab. Design and control approaches developed for the Alstonvale House provided the basis for generalized control strategies applicable to optimally designed solar homes. Simplified …

    concordia Download PDF for A Study of Predictive Control Strategies for Optimally Designed Solar Homes (opens in a new tab)

  12. Optimal application of phase change materials and passive cooling systems to improve energy and indoor environmental performance of a highly glazed commercial space in cold climates

    … was a graduate study room located on the top floor of the SPEB. The study concluded that the integration of PCM28 with the hydronic radiant floor system significantly reduces the annual heating and total energy demand by around 24% and 19%, respectively. Also, the economic analysis showed that …

    manitoba Repository record for Optimal application of phase change materials and passive cooling systems to improve energy and indoor environmental performance of a highly glazed commercial space in cold climates (opens in a new tab)

  13. The design of a residential water-to-water heat pump

    … heating is to be accomplished by means of a radiant floor panel. This requirement together with the proximity of a boundless supply of water to use as the heat pump sink and heat source, suggests the use of a water-to—water heat pump system. As a radiant floor panel cannot be used to cool, …

    vt Repository record for The design of a residential water-to-water heat pump (opens in a new tab)

  14. Predicting the Performance of a Solar Domestic Water Heating System with Evacuated Tube Collectors and Hydronic Radiant Flooring

    … The system is designed to provide hydronic radiant floor heating to its occupants based on the heat loss of a building energy model for an energy-efficient home. Performance characteristics of the components from well-known manufacturers are utilized where available. Some of the parameters …

    unlv Repository record for Predicting the Performance of a Solar Domestic Water Heating System with Evacuated Tube Collectors and Hydronic Radiant Flooring (opens in a new tab) Download PDF for Predicting the Performance of a Solar Domestic Water Heating System with Evacuated Tube Collectors and Hydronic Radiant Flooring (opens in a new tab)

  15. Performance Analysis of Two Alternative Hvac Systems for the Unt Zero Energy Lab

    … heat source. Here, water to water heat pump with radiant floor and water to air heat pump with air ducts provide heating & cooling of the building. In this paper electricity consumption, comfort, cost & efficiency analysis is done for the existing system using Energy Plus simulation software. …

    unt Repository record for Performance Analysis of Two Alternative Hvac Systems for the Unt Zero Energy Lab (opens in a new tab)

  16. Design for human comfort outdoors in cold climates, with specific reference to Winnipeg transit stops

    … The existing bus shelter was retro-fitted with a radiant floor heating system, a radiant-heated bench, and solar powered lighting and ventilating system. The University of Manitoba will provide maintenance support for the prototype and Professor Leon Feduniw and his students will monitor the …

    manitoba Repository record for Design for human comfort outdoors in cold climates, with specific reference to Winnipeg transit stops (opens in a new tab)

  17. An energy and cost analysis of residential ground-coupled heat pumps in Iowa

    … ground-coupled heat pumps without radiant floor heating. All homes were constructed between 1997 through 2001 and are of typical construction. The homes studied are distributed throughout the state of Iowa. It was also desired to compare heat pumps to natural gas furnaces for …

    iastate Repository record for An energy and cost analysis of residential ground-coupled heat pumps in Iowa (opens in a new tab)

  18. Development of Heuristic Model-Based Predictive Control Strategies for an Institutional Net-Zero Energy Building

    … predictive control strategy is applied to a radiant floor heating system. Depending on anticipated weather scenarios, developed near-optimal heating temperature setpoint profiles are selected. A generalized methodology for building energy model development to be used by model predictive …

    concordia Download PDF for Development of Heuristic Model-Based Predictive Control Strategies for an Institutional Net-Zero Energy Building (opens in a new tab)

  19. Dynamic Modeling and Control of a Hybrid Hydronic Heating System

    … loop heat exchanger, baseboard heaters, and radiant floor hydraulic piping systems. The system model was described by nonlinear differential equations, which were programmed and solved using MATLAB. Two control strategies for improving the overall system performance were explored: (i) a …

    concordia Download PDF for Dynamic Modeling and Control of a Hybrid Hydronic Heating System (opens in a new tab)

  20. Second law analysis of residential heating systems

    … heaters, (b) forced air system, and (c) radiant heating floor; (2) heating equipment: (a) electric or gas-fired boiler, (b) ground-source-heat-pump, and (c) air-to-air heat pump; (3) heat recovery: (a) air-to-air heat exchanger, (b) earth-tube heat exchanger, and (c) boiler economizer. …

    concordia Download PDF for Second law analysis of residential heating systems (opens in a new tab)