Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"radiation dosimeters"”.
-
Passive Wireless Radiation Dosimeters for Radiation Therapy Using Fully-Depleted Silicon-on-Insulator Devices
Radiation cancer therapy is one of the most important methods of cancer treatment. The goal of radiation therapy is to apply maximum amount of dose to the tumor region while applying minimum amount of dose to the normal tissues. Being able to measure radiation dose accurately is critical for …
-
A PATTERN RECOGNITION APPROACH TO LEARNING TRACKS OF HEAVY-ION PARTICLES IN TIMEPIX DETECTORS
… an active personal dosimeter for use in space radiation environments. The work reported here is based on the Timepix chip, which when coupled with an Si sensor, can function as an active nuclear emulsion, allowing the visualization of the individual tracks created as the different incident …
-
Ultraviolet Photosimulated Thermoluminescence of Lithium Flouride
TLD-100 (lithium fluoride) thermoluminescence dosimeters are widely employed for the detection of ionizing radiations. This paper shows that these dosimeters may also serve as practical germicidal ultraviolet radiation dosimeters. To measure ultraviolet radiation, the TLD-100 dosimeters are first …
-
A New Transduction Mechanism for Detecting Biological Radiation Damage using Metabolic Response of Yeast as a Surrogate Marker
Radiation was a serendipitous discovery in the late 19th century and since then has been an effective tool utilized in many different fields such as energy, weaponry, medical diagnosis/treatment, food sterilization, and archaeological. As its demand increased in multiple areas, it became necessary …
-
INJECTABLE HYDROGELS THAT CAN MEASURE RADIATION AT BODY TEMPERATURE
Hydrogel-based radiation dosimeters are used to calibrate and validate radiation delivered by linear accelerators used in radiotherapy. Specifically, Fricke hydrogel-based dosimeters containing ferrous ion complexes oxidize upon exposure to radiation, leading to a change in optical density that can …
-
X-ray computed tomography for performing polymer gel dosimetry : a feasibility study
Radiation therapy treatment of cancer is increasingly concerned with delivering dose distributions that conform to the tumour volume. For verification of treatment planning computer dose calculations, these conformal therapies demand an accurate, sensitive, high resolution three dimensional (3D) …
-
Carbon Nanotube and Carbon Fibre Based Radiation Dosimetry
… are inherently dependent on accurate radiation dosimetry. Over the last few decades, ionization chambers, thermoluminescence dosimeters (TLDs), film dosimeters, and semiconducting dosimeters have been commonly used in radiotherapy. However, the shortcomings of each type of dosimeter …
-
CMOS low-power threshold voltage monitors circuits and applications
… sensors, voltage and current references, radiation dosimeters and other applications since the MOSFET VT0 dependence on the operation conditions is a very well modeled aspect. Also, it can be used for fabrication process monitoring and process variability compensation, since VT0 is a key …
-
Characterization of small high energy proton beams in homogenous and heterogenous media
… fields in radiotherapy. Small photon field irradiation is aimed at delivering a uniform dose to a well defined target while minimizing the dose to the surrounding normal tissue. The dosimetry of small x-ray fields is complicated by two factors: the relationship between detector size and field …
-
Carbon Nanotube Based Dosimetry of Neutron and Gamma Radiation
… 20 years, accurate information regarding neutron radiation exposure is more important than ever. Structural components such as the reactor pressure vessel (RPV) become embrittled by neutron irradiation, reducing their capability to resist crack growth and increasing the risk of catastrophic …
-
Gamma irradiation response of photonic crystal and standard optical fibre Bragg grating sensors for radiation dosimetry
… Fibre Bragg Grating Sensors (FBGs) for Gamma Radiation Dosimetry. A comparative analysis of responses to gamma irradiation between standard commercial FBGs and new generation FBGs written in Photonic Crystal fibre (PCF) were examined under similar regimes and conditions. Current research …
-
X-Ray Induced Luminescence of Sapphire and Ruby
… ruby are at present used as lasing materials, radiation dosimeters, and as optical windows. In order that these operations may be made more efficient, and that other useful luminescent properties may be systematically explored and developed, much attention has been given to understanding the …
-
Development of an external beam line for radiobiology experiments and microdosimetry applications at the 18 MeV proton cyclotron facility at CNA
… between the doses of the reference and studied radiation determining the same effect. In clinical proton therapy, a RBE value of 1.1 is currently used. However, there is an increasing awareness that proton RBE is not a constant, but seems to increase linearly with the Linear Energy Transfer (LD) …
-
Tissue equivalent X-ray dosimetry based on carbon nanotubes
… The effects of 0.20 Gy and 0.45 Gy X-rays radiation on Single-Wall Carbon Nanotubes (SWCNTs) are studied in order to explore their use as miniaturised and highly sensitive radiation detectors. Scanning Electron Microscopy (SEM), Raman Spectroscopy and X-ray Photoelectron Spectroscopy (XPS) …
-
Facilitating the Clinical Translation of Flash Radiotherapy Through Dosimetry Development and Beam Parameter Optimization
Advisory Professor: Emil Schüler, PhD Radiation therapy (RT) is a crucial component of curative cancer therapy, with a majority of cancer patients in the United States receiving RT as part of treatment. The goal of RT is to maximize the therapeutic index in curing disease while minimizing any …
-
New dosimetry methods for radiological and nuclear emergency management
… with regard to their potential to act as radiation dosimeters. The work in this thesis investigates the properties of common household salt and talc, using portable Optically Stimulated Luminescence (OSL) and Infra-Red Stimulated Luminescence (IRSL) instruments capable of rapid …
-
CMOS radiation sensor design in 130nm CMOS technology : a thesis presented in partial fulfillment of the requirements for the degree of Master of Engineering in Electronics and Computer Engineering at School of Engineering and Advanced Technology, Massey University, Albany Campus
This research work deals with a CMOS radiation sensor design, which covers a new open source floating-gate MOSFET (FGMOSFET) device model for analog circuit design, Floating Gate Radiation Field Effect Transistor (FGRADFET) design, FGRADFET sensor output circuit design and their layout …