Results 1 to 20 of 33 for “"radio frequency quadrupole"”
-
Ion injection into radio frequency quadrupole field devices
This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …
-
Study of the impact of operational conditions on radio frequency quadrupole material properties
… and long-term structural integrity of Radio-Frequency Quadrupoles (RFQs), with emphasis on radiation-induced degradation mechanisms in structural Cu-OFE copper. This project is focused on the ESS RFQ conditioning and commissioning, microstructural Cu-OFE copper characterization, …
-
First tests of a square wave radio frequency quadrupole cooler and buncher for TITAN
A high frequency, large amplitude helium filled RFQ (Radio Frequency Quadrupole) beam cooler and buncher was developed and tested for use in the TITAN (TRIUMF's Ion Trap for Atomic and Nuclear science) Penning trap mass spectrometer facility. This device will cool and bunch radioactive ion beams …
-
An electrostatic decelerator for a high-field radio-frequency quadrupole ion guide beam cooler /
An electrostatic decelerator system capable of bringing to rest a continuous 60 keV DC ion-beam was developed and tested as to its suitability as the first part of a high-performance RFQ buffer gas beam cooler. The decelerator is intended to decelerate high-energy ions for injection into an RFQ …
-
The transport of radioactive ions in a gas filled radio frequency quadrupole mass filter system /
The technique of ion transfer in radio frequency quadrupole (RFQ) systems is described. Computer simulations of the gas filled RFQ mass filter system located at Argonne National Laboratory (ANL) in Argonne, Il. are performed and compared to data obtained from the transfer of radioactive ions …
-
TUNING OF THE RADIO FREQUENCY QUADRUPOLE FOR THE FRONT END TEST STAND AT RUTHERFORD APPLETON LABORATORY
… mA beam of H- ions to 3 MeV at 50Hz with an RF frequency of 324 MHz. It is designed to demonstrate a high beam current with fast chopping. It is also being considered for the ISIS II upgrade. The FETS RFQ is the main accelerating structure, and the 3 MeV final energy is reached at the end of …
-
Production of a cooled ion beam by manipulation of 60-keV ions into a radio-frequency quadrupole ion guide
… CERN (Geneva, Switzerland) into a new segmented radio-frequency quadrupole (RFQ) ion guide at the ISOLTRAP experiment. A detailed computer simulation of the ion motion through the electrostatic decelerating and focusing electrodes into the RFQ ion guide was carried out. A complete decelerating …
-
Buffer gas cooling of ions in a radio frequency quadrupole ion guide : a study of the cooling process and cooled beam properties
… the properties of the cooled beam in a novel rf quadrupole ion beam guide with axial field was studied. The operation principle of the axial field quadrupole ion beam guide is similar to the quadrupole mass filter operating in AC only mode but the rods were segmented and differential DC biases …
-
Installation and operation of a radio-frequency quadrupole cooler and buncher and offline-commissioning of the TRIGA-SPEC ion beam preparation transfer line
… the implementation and commissioning of a radio-frequency quadrupole for the emittance reduction and accumulation of the ions. The functionality of the ion beam preparation was verified by successful test measurements of stable nuclides produced in the online ion source.
-
A Radio Frequency Quadrupole Instrument for use with Accelerator Mass Spectrometry: Application to Low Kinetic Energy Reactive Isobar Suppression and Gas–phase Anion Reaction Studies
A radio frequency (rf) quadrupole instrument, currently known as an Isobar Separator for Anions (ISA), has been integrated into an Accelerator Mass Spectrometry (AMS) system to facilitate anion–gas reactions before the tandem accelerator. An AMS Cs+ sputter source provided > 15 keV ions that were …
-
New developments on preparation of cooled and bunched radioactive ion beams at ISOL-Facilities: the ISCOOL project and the rotating wall cooling
… devoted to the production of beams with exotic radioisotopes (Radioactive Ion Beams, RIB). These beams are later used for experiments in fields like nuclear physics, atomic physics, astrophysics or medicine, among others. Within this kind of facilities, the ISOL facilities stand out. They are …
-
Bunched beams from RFQ traps for laser spectroscopy studies
… = 589 nm) on continuous atomic beams. A radio-frequency quadrupole ion trap and its associated electronics have been assembled and successfully operated, trapping $ sp{23}$Na$ sp{+}$ ions from an external source built for the purposes of this work. The bunched ions were extracted and …
-
A tandem Paul-Penning trap mass measurement system for radionuclides
… collection efficiency through the use of a Paul (radio-frequency quadrupole) ion trap as a collection device for preparing the radionuclides before the measurement system is then presented. Results from engineering tests on the performance of the Paul trap at the ISOLDE facility are discussed. The …
-
Ion accumulation in a Paul trap for the Canadian Penning Trap Mass Spectrometer
… source, used for stable isotope production; a radio-frequency quadrupole ion trap (Paul trap); and a Penning trap, which sits inside a homogeneous 6 Tesla magnetic field. The CPTMS was tested using gold ions: these were accelerated toward the Paul trap, where they were accumulated and cooled …
-
A new ion beam cooler and buncher for ISOLTRAP and mass measurements of radioactive argon isotopes
… buncher for ISOLTRAP and mass measurements of radioactive argon isotopes - ISOLTRAP is a Penning trap mass spectrometer installed at ISOLDE/CERN. It is set up to measure the mass of short-lived nuclides with a relative accuracy delta m / m of typically 1* 10^-7. In this work an ion beam cooler …
-
Development of the TAMUTRAP Facility for Precision Beta-Decay Studies
… for precision nuclear physics experiments with radioactive beams provided by the Cyclotron Institute. Its primary focus is to search for possible scalar currents in T = 2 superallowed β-delayed proton decays, which, if found, would be an indication of physics beyond the standard model. In …
-
An in-situ accelerator-based diagnostic for plasma-material interactions science in magnetic fusion devices
… The diagnostic uses a compact, high-current radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak. The tokamak magnetic fields in between plasma shots are used to steer the deuterons to PFCs where the deuterons cause high-Q nuclear reactions with …
-
Développement et réalisation d'un klystron à haut-rendement de type kladistron
… sont modulés afin de d'amplifier un signal radiofréquence. Pour ce faire, des cavités passives constituant la ligne d’interaction du klystron échangent de l’énergie électromagnétique avec le faisceau. Il en résulte une modification périodique de la vitesse des électrons, qui sont regroupés …
-
Um acelerador linear compacto para a produção de radioisótopos de tomografia por emissão de pósitrons (PET): estudos preliminares
… production of Positron Emission Tomography (PET) radioisotopes in the forthcoming Brazilian Maximum Biological Containment Laboratory (LNMCB), a biosafety level 4 (BSL-4) laboratory under construction inside the campus of the Brazilian Center for Research in Energy and Materials (CNPEM). The local …