Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 111 for “"radiochromic"”
-
Iterative image reconstruction for optical CT radiochromic gel dosimetry
… can be accurate and practical, making optical CT radiochromic gel dosimetry more viable for routine clinical use.
-
Implementation of an in vivo radiochromic film QA procedure
… vivo dosimetry quality assurance procedure using radiochromic film. This research proved that radiochromic in vivo dosimetry is a viable method of detecting spatial patient specific errors in radiotherapy; however, the process is time consuming and not sensitive enough for dosimetric errors …
-
THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER
This research aims to develop a tissue-mimicking material and produce a 3D gelatin that has density of approximately a human lung, which is in the ranges of (0.25 – 0.35) g/cm3. Tissue equivalent models are important in order to study the radiation dose planned for patients. To achieve the desired …
-
Development of a Novel Readout System for Radiochromic Film Dosimetry
… precisely delivered to a patient is critical. Radiochromic film dosimetry has been adopted in the clinic as a convenient option for QA because it provides verification in a two dimensional plane, is essentially energy independent, is near tissue equivalent, and has high spatial resolution. …
-
DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER
… of this research is to fabricate a transparent radiochromic gel dosimeter that may be used as quality assurance tool. Also, the fabricated gel must be analyzed using a simple optical read-out technique.</p> <p>Gel dosimeters are gels that undergo some chemical changes upon irradiation as a …
-
Characterization of Tetrazolium Salts and Formazans using Computational Chemistry for Radiochromic Dosimetry
Computational chemistry is a powerful tool to model different materials and predict their physical and chemical properties. The goal of this thesis was to apply different computational chemistry tools to model the properties of two classes of closely related organic compounds: formazans and …
-
Development of radiochromic film dosimetry at micrometric scale for microbeam radiation therapy
But de l’étude:La radiothérapie par microfaisceaux (Microbeam Radiation Therapy: MRT) est une nouvelle approche de la radiothérapie pour le traitement du cancer et de certaines maladies neurologiques basée sur des champs spatialement fractionnés à l'échelle micrométrique. La MRT est réalisée avec …
-
IMRT Plan Delivery Verification Utilizing a Spiral Phantom with Radiochromic Film Dosimetry
… planar fluence dose and measured dose using radiochromic film. A solid water cylindrical IMRT phantom manufactured by GAMMEX which has been machined creating a spiral cavity for placement of radiochromic film (GAFCHROMIC® EBT2) was employed for IMRT plan QA. This spiral phantom is implemented …
-
Beta and electron dose imaging using a microspectrophotometer system and radiochromic film
… using a microspectrophotometer system and radiochromic film, has been investigated. The investigation entailed the commissioning of the microspectrophotometer and the development of a newly proposed method in film calibration. It was tested successfully by comparing the measured dose, …
-
Exploring spatial heterogeneity of radiation dose deposition with radiochromic film and Raman spectroscopy
This thesis considers dosimetric analysis of EBT-3 films using Raman spectroscopy, aiming to use spectral data to investigate spatial heterogeneity associated with radiation exposure at about the cellular-level of granularity. Herein, we identify two principal peaks serving as indicators of dose …
-
Role of water in radiochromic LiPCDA monomer crystal packing and radiotherapy dose response
Radiochromic films comprised of lithium-10,12-pentacosa diynoate (LiPCDA) crystals, a form of diacetylene, have been developed for in vivo real-time dosimetry. The polymerization of LiPCDA results in a change in optical density that is related to the absorbed dose. The dose response of diacetylene …
-
Point-based Ionizing Radiation Dosimetry Using Radiochromic Materials and a Fibreoptic Readout System
… quality assurance and innovation. Two radiochromic materials from GafChromic MD-55 and EBT films have been investigated for applicability in real-time in vivo dosimetry of ionizing radiation. Both films were able to produce a real-time measurement of optical density from a small volume, …
-
Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields
… indirectly ionizing radiation dosimetry by using radiochromic film (RCF) for a high-resolution, accurate dosimetry system. Using RCF will extend the current field of radiation dosimetry to spatially quantitative 2D and three-dimensional (3D) measurements. </p> <p>This work was generalized into two …
-
The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods
… thesis was to fabricate a transparent cryogel radiochromic dosimeter with poly(vinyl alcohol) (PVA) as the gelling agent. A transparent dosimeter may be analyzed using an optical read out technique, which is desirable. PVA cryogels can be made transparent by adding dimethyl sulfoxide (DMSO). …
-
Photo- and radiochromic transformations in Al2O3:C,Mg fluorescent nuclear track detectors and high resolution imaging of radiation fields
Scope and Method of Study: The goal of this work was to develop fluorescent nuclear track detectors (FNTD) based on aluminum oxide doped with carbon and magnesium (Al2O3:C,Mg) as a multi-purpose radiation detection technology. The study focused on the optical properties of Al2O3:C,Mg as well as on …
-
Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout
… and complete dosimeters for brachytherapy. Radiochromic gel dosimeters with optical computed tomography (CT) readout would provide such a dosimeter, but the insertion of brachytherapy catheters into the gel cause streak artifacts in the reconstructed dose distributions, ruining the …
Page 1 of 6