Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"radiofrequency pulses"”.
-
Design of multidimensional radiofrequency pulses in magnetic resonance imaging
Multidimensional radiofrequency (RF) pulses have wide applications in magnetic resonance imaging and spectroscopy experiments. These applications include reduced field-of-view (FOV) imaging of region-of-interest (ROI), B1 inhomogeneity correction, and simultaneous spatial-spectral selective …
-
Design of Multidimensional Large -Tip -Angle Radiofrequency Pulses for Parallel Transmission in Magnetic Resonance Imaging
… excitation principle to multidimensional RF pulses (including both single-channel and parallel transmission) is first identified. Then, an alternative approach using a new class of spiral trajectories, termed the variable slew-rate spirals, is proposed to locally reduce B 1 amplitude of 2D RF …
-
New techniques in nuclear magnetic resonance
<p>The effect of short, strong radiofrequency pulses on the nuclear spin system is examined. Providing the durations of the pulses are short with respect to coupling constants within the spin system, they may be described by simple rotation operators which are exponential functions of the angular …
-
Improving Data Quality for Functional Magnetic Resonance Imaging
… signal in grey matter and hyperbolic secant (HS) radiofrequency pulses aimed to reduce the dropout caused by through-plane susceptibility gradients. The third, using a combination of the HS pulse with compensatory gradients in the frequency encoding direction, aimed to further reduce the dropout …
-
SIMULTANEOUS ARTIFACTS CORRECTION AND ACCELERATION FOR CHEMICAL EXCHANGE SATURATION TRANSFER IMAGING VIA DEEP LEARNING
… rely on molecular signal saturation through radiofrequency pulses with the same frequency as a prescribed molecule (e.g., glutamate) to be measured in a magnetic field. Because the background signal from water modular is generally greater than the signal from the prescribed molecular by …
-
Coherent transfer between electron and nuclear spin qubits and their decoherence properties
… uses a series of resonant mi- crowave and radiofrequency pulses and is shown with a two-way fidelity of around 90% for an arbitrary qubit state. The transfer allows quantum information to be held in the nuclear spin for up to 3 orders of magnitude longer than in the electron spin, producing …
-
Robust Magnetic Resonance Imaging of Short T2 Tissues
… with adjustable parameters, including optimized radiofrequency pulses, trajectories, choice of two or three dimensions, and multiple long-T2 suppression techniques. Together with the FUSE sequence, an improved analytical density correction and an auto-deblurring algorithm were incorporated as …
-
Developing microwave probes for investigating opto-electronic processes in photovoltaic materials
… in NMR spectroscopy that the use of shaped radiofrequency pulses can increase the fidelity, excitation bandwidth and sensitivity of NMR techniques. Technical challenges associated with implementing shaped microwave pulses have inhibited the widespread application of these techniques in EPR …
-
Bayesian inference for physiological MRI by using deep learning techniques
… which applies a strong magnetic field and radiofrequency pulses at resonant frequency to certain atomic nuclei for example hydrogen nuclei. Through monitoring the interaction between labeled nuclei and the surrounding environment, the physiological information of tissues can be captured in …
-
Investigation and development of MRI-based multi-compartment myelin imaging methods
… sequence that uses non-selective multiband radiofrequency pulses to generate contrast more efficiently than literature methods. Combination of this sequence and state-of-the-art magnetic resonance fingerprinting acquisition and reconstruction strategies has provided promising phantom and in …
-
Dynamic nuclear polarisation as a probe of metabolism in pathophysiology
… sequences of spectrally-and-spatially selective radiofrequency pulses and rapid imaging readouts that are able to image the metabolism of hyperpolarised [1-<sup>13</sup>C]pyruvate in three dimensional space, with a reconstructed resolution of 1 × 1 × 2 mm<sup>3</sup>. The technique’s sensitivity …
-
Quantitatively Studying Tissue Damage in Multiple Sclerosis Using Gradient Recalled Echo MRI Sequences
… “bound” water proton pools. Importantly, no MT pulses are used in SMART approach, thus overcoming high RF energy deposition associated with existing qMT approaches for evaluation of tissue macromolecular content. From a single protocol this technique can generate quantitative macromolecular …
-
Quantitatively Studying Tissue Damage in Multiple Sclerosis Using Gradient Recalled Echo MRI Sequences
… “bound” water proton pools. Importantly, no MT pulses are used in SMART approach, thus overcoming high RF energy deposition associated with existing qMT approaches for evaluation of tissue macromolecular content. From a single protocol this technique can generate quantitative macromolecular …
-
1H and 15N hyperpolarization using SABRE : experimental approaches and hardware designs for continuous and batch hyperpolarization
… as coils for static magnetic field generation, radiofrequency-pulses and signal reception. Manufacturing methods mostly used after manual constructions were milling, lathing and 3D-printing. Using the equipment built in this work, high SABRE polarized samples were produced and measured in …
-
Experimental Techniques and Image Reconstruction for Magnetic Resonance Imaging with Inhomogeneous Fields
… fields involved. A novel method of decreasing radiofrequency pulse duration for multidimensional pulses is presented, rendering them more robust to field inhomogeneity. Furthermore, this method is leveraged to accelerate data acquisition. A new imaging sequence for quantitative determination of …
-
Quantitative Magnetic Resonance Imaging in the Brain for Radiotherapy Response Assessment
… (ASL) technique. ASL uses strategically applied radiofrequency pulses to the water in blood to reveal perfusion in vivo without the need for a contrast agent injection. A mathematical model of the ASL signal was implemented to find an appropriate selection of the sequence parameters on that …