Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"radiolucent lines"”

  1. Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I)

    … change found during the follow-up was evaluated. Radiolucent lines at the tibial component–bone interface were observed οn anteroposterior radiographs early from the third year, in zones Ι and ΙV in 14 knees (13.2%). These radiolucent lines were no larger than 1mm and did not progress throughout …

    greece Repository record for Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I) (opens in a new tab)

  2. Fixation of the Oxford unicompartmental knee replacement

    … a good clinical outcome at 15 years, however, radiolucent lines are commonly found beneath the tibial tray. With the projected increase in knee arthroplasty, particularly in younger patients, implant longevity is of paramount importance. The aim of this thesis is to understand how fixation is …

    oxford Repository record for Fixation of the Oxford unicompartmental knee replacement (opens in a new tab)

  3. Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies

    … (RingLoc and Regenerex) for the development of radiolucent lines at the implant-bone interface and cup migration up to five years. In Study I, femoral head penetration into cups with liners made of either vitamin E-infused highly cross-linked polyethylene (E1) or compression-annealed highly …

    goteborg Repository record for Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies (opens in a new tab)

  4. Knee joint kinematics and the effects of arthropasty component design

    … was measured with radiostereometry, and radiolucent lines and clinical outcome were evaluated in 72 knees. Study 5: The kinematics of 22 knees operated with the Freeman-Samuelson (Finsbury Instruments Ltd, Surrey, UK) TKR due to non-inflammatory arthrosis were recorded by dynamic …

    goteborg Repository record for Knee joint kinematics and the effects of arthropasty component design (opens in a new tab)

  5. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters

    … radiography revealed higher progression of radiolucent lines in the Palacos group, but only in one region. Study V: The proximal migration of the cup was almost similar in all three groups. The three dimensional migration was increased in patients with osteoporosis. Postoperative radiolucent …

    goteborg Repository record for New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters (opens in a new tab)

  6. Investigation of improved fixation in massive endo-prosthetic replacements of the lower limb

    … was a correlation between pain and radiographic radiolucent lines. This study provided impetus to develop three new method of improving implant fixation. These were - 1. enhanced fixation of cemented intra-medullary stemmed replacements using porous beaded collars or hydroxyapatite coated …

    ucl Repository record for Investigation of improved fixation in massive endo-prosthetic replacements of the lower limb (opens in a new tab)

  7. The souter-strathclyde elbow prosthesis in rheumatoid patients : an in-depth clinical, radiological and biomechanical analysis

    … the follow-up in a standardized manner. Since radiolucent lines (RLLs) are the radiological indication in the loosening process, the elbow components position in the bone was related to the development and progression of these RLLs. It was hypothesized that prosthetic position did influence the …

    leiden Repository record for The souter-strathclyde elbow prosthesis in rheumatoid patients : an in-depth clinical, radiological and biomechanical analysis (opens in a new tab)

  8. Fixation of the cementless oxford unicompartmental knee replacement

    … improve fixation, reduce the incidence of radiolucent lines and ultimately reduce the discrepancy between the results of specialist centres and National Joint Registries. There are, however, anecdotal reports of tibial plateau fractures with cementless fixation. The aim of this thesis was …

    oxford Repository record for Fixation of the cementless oxford unicompartmental knee replacement (opens in a new tab)

  9. Humeral stem loosening following reverse shoulder arthroplasty - systematic review and meta-analysis

    … the incidence of aseptic stem loosening, humeral radiolucent lines (RLL) and revision for stem loosening between: 1) cemented and uncemented stems, and 2) different etiological subgroups Methods: In a systematic review 75 articles were included after assessment of study methodology and a …

    cape-town Repository record for Humeral stem loosening following reverse shoulder arthroplasty - systematic review and meta-analysis (opens in a new tab)

  10. Investigating Acetabular Cup Fixation in Cemented Total Hip Replacements

    … modifications.The data shows that progressive radiolucent lines in the Charnley acetabular zone I, as well as postoperative pain and poor function, were associated with failure of the cup through aseptic loosening. In the mechanical investigation, fewer acetabular keyholes with a larger …

    bath Repository record for Investigating Acetabular Cup Fixation in Cemented Total Hip Replacements (opens in a new tab)

  11. The Use of Hydroxyapatite-coated Collars Enhances Osteointegrated Extra-cortical Bone Formation and Improves Long Term Survival of Distal Femoral Endoprostheses

    … use of a HA collar reduces the progression of radiolucent lines and results indicate that implants with osteointegrated HA collars, inserted into adolescent patients remain more firmly attached to the skeleton than nonosteoinegrated HA collars. This suggests that HA collars can enhance the …

    ucl Repository record for The Use of Hydroxyapatite-coated Collars Enhances Osteointegrated Extra-cortical Bone Formation and Improves Long Term Survival of Distal Femoral Endoprostheses (opens in a new tab)

  12. Enhancing the fixation of massive implants using bone marrow stromal cells.

    … (p=0.02). Application of oBMSCs also reduced the radiolucent lines present between the new bone and implants, and improved bone-implant contact. This study demonstrated the potential of BMSCs to augment bone growth and bone-implant contact in conjunction with massive implants. The second in vivo …

    ucl Repository record for Enhancing the fixation of massive implants using bone marrow stromal cells. (opens in a new tab)

  13. Cementless knee replacement. Experimental, clinical and radiostereometric investigations of the tibial component

    … low in both groups (0.5 mm). There were more radiolucent lines under the tibial tray and around the stem in the uncoated group. HA/TCP coating seems to improve the quality of the interface between the tibial component and the bone.The amount of bone mineral (BMA) was measured by triple-energy …

    goteborg Repository record for Cementless knee replacement. Experimental, clinical and radiostereometric investigations of the tibial component (opens in a new tab)

  14. Instrumentation optimisation for unicompartmental knee replacement

    … years. Cementless OUKRs (1/15) had fewer tibial radiolucent lines compared to cemented (6/14) at 10 years.</p> <p>Bearing fractures, because of excessive polyethylene wear, have been reported with the Phase III OUKR. There is a concern that cementless fixation might be associated with increased …

    oxford Repository record for Instrumentation optimisation for unicompartmental knee replacement (opens in a new tab)

  15. Outcome after medial unicompartmental knee replacement

    … to suffer from pain.</p> <p>The presence of radiolucent lines (RLL) following a joint replacement is usually deemed to be indicative, or predictive, of loosening. 63% of Oxford UKRs were found to have RLL under the tibial component. No correlation was found between RLL and outcome, …

    oxford Repository record for Outcome after medial unicompartmental knee replacement (opens in a new tab)

  16. Μεσοπρόθεσμα και μακροπρόθεσμα κλινικά και ακτινολογικά αποτελέσματα των κυπελίων από σπογγώδες ταντάλιο σε ασθενείς με ολική αρθροπλαστική του ισχίου

    … loose components, migration or progressive radiolucent lines. Three cups were revised due to mal position and instability and one more hip had a femoral stem revision due to fracture of the lesser trochander. . Only 35% of τηε gaps and 6,19% of the cysts were filled-in completely by the end …

    greece Repository record for Μεσοπρόθεσμα και μακροπρόθεσμα κλινικά και ακτινολογικά αποτελέσματα των κυπελίων από σπογγώδες ταντάλιο σε ασθενείς με ολική αρθροπλαστική του ισχίου (opens in a new tab)

  17. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty

    … of the tibial component and the development of radiolucent lines were of the same magnitude for the flat versus the concave inserts in study 3 and the concave versus the PS designs in study 4. The positioning of the implant and the fulfilment of the patients expectations on the surgery …

    goteborg Repository record for Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty (opens in a new tab)

  18. Η χρήση των βραχέων μεταφυσιακών στυλεών στην πρωτοπαθή οστεοαρθρίτιδα του ισχίου: ανάλυση πεπερασμένων στοιχείων (finite element analysis), πειραματική εμβιομηχανική μελέτη (experimental biomechanichal testing) και προοπτική, τυχαιοποιημένη συγκριτική μελέτη δυο διαφορετικών στυλεών σε ασθενείς με πρωτοπαθή οστεοαρθρίτιδα του ισχίου

    … with no cases of aseptic loosening, progressive radiolucent lines or periprosthetic osteolysis. In the current comparative clinical study and in accordance with the conclusions of the experimental study, stress shielding phenomenon was also noted after the implantation of both short stem designs. …

    greece Repository record for Η χρήση των βραχέων μεταφυσιακών στυλεών στην πρωτοπαθή οστεοαρθρίτιδα του ισχίου: ανάλυση πεπερασμένων στοιχείων (finite element analysis), πειραματική εμβιομηχανική μελέτη (experimental biomechanichal testing) και προοπτική, τυχαιοποιημένη συγκριτική μελέτη δυο διαφορετικών στυλεών σε ασθενείς με πρωτοπαθή οστεοαρθρίτιδα του ισχίου (opens in a new tab)

Page 1 of 2