Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"range uncertainty"”.
-
Range uncertainty reductions in proton therapy and associated benefits for patients with brain or skull base tumors
… of these are uncertainties in the in vivo proton range, which stem from factors such as the images on which treatment plans are created and variations in patient setup between different treatment fractions. Such range uncertainties currently prevent the potential advantages of proton therapy from …
-
Dual Energy Computed to mography For Proton Therapy Treatment Planning
… in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when …
-
A Novel Method of Sub-milimeter Range Verification for Hadron Therapy using a Tumour Marker
… a novel technique for in-vivo proton therapy range verification, and share the results of multiple experiments to determine its feasibility. This technique makes use of a hadron tumour marker (HTM), implanted at a short distance from the clinical treatment volume. Signals emitted from the …
-
Improvements In Robustness and Optimality of Intensity-Modulated Proton Therapy Plans For Lung Cancer Patients With 4-Dimensional Robust Optimization
… both respiratory motion as well as to setup and range uncertainties simultaneously. For full 4DRO, the effect of respiratory motion, characterized by different phases of 4D computed tomography (CT), was incorporated into a 4DRO algorithm. Dose distributions from multiple setup and range …
-
Three-Dimensional Medical Image Registration with Applications in Proton Therapy
… stopping-power ratio map, reducing proton beam range uncertainty. To address the inter-scan motion artifacts inherent in sequential DECT acquisition, we propose a novel motion-compensation scheme to incorporate a three-dimensional DIR method into the joint statistical iterative DECT …
-
Range Adaptive Proton Therapy For Prostate Cancer
… structures are avoided due to concerns of range uncertainties, such as CT number conversion and anatomy variations. We propose to eliminate range uncertainty and enable prostate treatment with a single anterior beam by detecting the proton’s range at the prostate-rectal interface and …
-
Intensity Modulated Proton Therapy Optimization Under Uncertainty: Field Misalignment and Internal Organ Motion
… to different uncertainties, such as setup uncertainty, range uncertainty and internal organ motion. These uncertainties can greatly impact the quality of clinical treatment. Therefore, this dissertation aims to investigate different optimization methods for treatment planning and to handle …
-
Quantification and management of uncertainties in radiation therapy
… for quantitative analyses of various types of uncertainty in proton therapy is developed. In the first project, an existing algorithm for scatter correction of cone beam computed tomography (CBCT) images is used to enable a dose recalculation on the changed patient anatomy. This is combined …
-
Implications of uncertain future network performance on satisfying environmental justice and tolling
… methods for exploring the pressing problems of uncertainty, Environmental Justice, and tolling as they relate to long-range transportation planning. While these topics are seemingly disparate, much of the work in this dissertation is motivated by the increasing number of roadway projects …
-
Evaluation and Clinical Implementation of a Dual-Energy CT Stopping-Power Ratio Mapping Technique for Proton-Therapy Treatment Planning
… rapid dose falloff at the end of the proton-beam range is correctly aligned to the edge of the clinical target volume (CTV). However, its clinical potential is dependent on the accurate localization of the Bragg-peak position from predicted stopping-power ratio maps. The method that is most …
-
Treatment verification in proton therapy based on the detection of prompt gamma-rays
Background The finite range of a proton beam in tissue and the corresponding steep distal dose gradient near the end of the particle track open new vistas for the delivery of a highly target-conformal dose distribution in radiation therapy. Compared to a classical photon treatment, the potential …
-
A new prompt gamma spectroscopy-based approach for range verification in proton therapy
… in a localized region close to the end of their range (called the Bragg Peak BP). The combination of the favorable depth-dose profile with advanced delivery techniques translates into a high dose conformality in the tumor, as well as into a superior sparing of normal tissue compared to …