Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"rating factor"”

  1. Assessment of Bridges with an Ohio Legal Load Rating Factor Greater than 1.35 to Meet Specialized Hauling Vehicle Requirements in Ohio

    … are required to incorporate SHVs in their load rating scheme and post bridges, if necessary.ODOT uses its own set of legal trucks (2F1, 3F1, 4F1 and 5C1) in place of AASHTO Type 3, 3-S2, and 3-3 legal trucks for load rating. A comparison of moments produced by the AASHTO SHVs showed an increase …

    ohiolink Repository record for Assessment of Bridges with an Ohio Legal Load Rating Factor Greater than 1.35 to Meet Specialized Hauling Vehicle Requirements in Ohio (opens in a new tab)

  2. Comparative study of LRFR and LFR methods of rating for Missouri concrete bridges

    Bridge load rating is a critical component of evaluating and managing bridge infrastructure, offering crucial insights into a bridge's capacity to safely handle traffic loads. The process is fundamental for both new and existing bridges, establishing weight restrictions on vehicles to prevent …

    umkc Repository record for Comparative study of LRFR and LFR methods of rating for Missouri concrete bridges (opens in a new tab)

  3. Truck Load Testing and Adjusted Load Rating of Ironton Russell Bridge

    … capacity of the section and load responses, the rating factors for towers, edge girders, and piers were calculated. As the rating factor is the ratio of capacity to demand, it is used to determine the critical locations in the bridge elements where the data acquisition for the sensor should be …

    ohiolink Repository record for Truck Load Testing and Adjusted Load Rating of Ironton Russell Bridge (opens in a new tab)

  4. Load Rating Study of Effects of Special Hauling Vehicle Loads on Ohio Bridges

    … Hauling Vehicles (SHVs), have lower load ratings than AASHTO legal loads. SHVs may cause forces by more than fifty percent in certain cases. These higher-force effects are for bridges with shorter spans, or elements with shorter load lengths, such as transverse floor beams.Per the FHWA, …

    ohiolink Repository record for Load Rating Study of Effects of Special Hauling Vehicle Loads on Ohio Bridges (opens in a new tab)

  5. Load Rating of Flat Slab Bridges Without Plans

    … on the existing bridge is used to calculate the rating factor of the bridge. The Ohio legal load vehicle of gross weight 30 kip having the truck load designation of OH-2F1 is considered for this research. The rating factor is determined as the ratio of truckload that produce the maximum allowable …

    ohiolink Repository record for Load Rating of Flat Slab Bridges Without Plans (opens in a new tab)

  6. Load Rating of Precast, Prestressed Adjacent Box Beam Bridges

    … for short to medium spans. Accurate load rating is critical to ensure safe load capacities, determine posting requirements, and support permit evaluations. The objective of this study is to verify the accuracy and reliability of a computer tool named AD-BOX: Adjacent Box Beam Bridge …

    ohiolink Repository record for Load Rating of Precast, Prestressed Adjacent Box Beam Bridges (opens in a new tab)

  7. Parametric Study for Assessment of Bridges to Meet Specialized Hauling Vehicles Requirements in Ohio

    … SHVs (Special Hauling Vehicles) in their load rating scheme and, if necessary, post bridges. Ohio-DOT uses its own set of legal trucks (2F1, 3F1, F1 and 5C1) in place of AASHTO (American Association of State Highway and Transportation Officials) type 3, 3-S2, and 3-3 legal trucks for load …

    ohiolink Repository record for Parametric Study for Assessment of Bridges to Meet Specialized Hauling Vehicles Requirements in Ohio (opens in a new tab)

  8. Condition based bridge management with SHM integration: A novel approach to remaining life estimation of bridges

    … University (ISU), by improving its current load rating calculation process. The current load rating approach underestimates the rating factor of a bridge by 20% to 40%. The load rating calculation process was improved by developing a relationship between moment of inertia and flexural strength of …

    iastate Repository record for Condition based bridge management with SHM integration: A novel approach to remaining life estimation of bridges (opens in a new tab)

  9. Improved Load Distribution for Load Rating of Low-Fill Box Structures

    … load carrying capacities is required for load rating of the culvert by determining a rating factor (RF) or truck tonnage of a HS truck. The rating factor is defined as the capacity of the structure minus the dead load demand, and then divided by the live load demand. All the state DOTs are …

    ku Repository record for Improved Load Distribution for Load Rating of Low-Fill Box Structures (opens in a new tab)

  10. Load Rating of Concrete Slab-span Bridges

    … in Brooklyn Center, MN have poor AASHTO load rating factors for certain truck configurations. Characterization of load distribution is useful for determining the load rating of bridges, but results in the literature have shown that the AASHTO code results in conservative load rating factors. …

    umn Repository record for Load Rating of Concrete Slab-span Bridges (opens in a new tab)

  11. A Bayesian Network-Based Methodology for Improved Bridge Load Rating and Asset Management

    … index, β, are directly determined. Bridge load ratings are used to indicate how much capacity is present in excess of that needed to support dead loads, or how much live load can still be supported without failure. A load rating can be calculated to reflect a target structural reliability. For …

    portland-state Repository record for A Bayesian Network-Based Methodology for Improved Bridge Load Rating and Asset Management (opens in a new tab)

  12. A framework for evidence integrity preservation in virtualized environment: a digital forensic approach

    … To simplify the analysis further, a reliability rating factor has been introduced as a means of defining conceptual integrity levels. We have mathematically modelled all the penalty parameters for data integrity in our model following widely known and recommended standards and processes. Although …

    bedfordshire Repository record for A framework for evidence integrity preservation in virtualized environment: a digital forensic approach (opens in a new tab)

  13. A multitrait-multimethod study of the construct validity of frequently used behavior rating scales for hyperactivity

    … students, and nonreferred students. Ratings were obtained from parents, teachers and youth. Multitrait-multimethod (MTM) matrixes were evaluated according to criteria proposed by Campbell and Fiske (1959). While correlations between similar traits measured by dissimilar methods (MH) …

    nebraska Repository record for A multitrait-multimethod study of the construct validity of frequently used behavior rating scales for hyperactivity (opens in a new tab)

  14. Iterative block ciphers’ effects on quality of experience for VoIP unicast transmissions under different coding schemes

    … for QoS and security for VoIP streams integrating both network impairments and user perception metrics into a novel empirically-driven approach. Specifically, the simulation model seeks the optimal parameters in terms of variable VoIP payloads, iterative block ciphers, codecs and …

    bedfordshire Repository record for Iterative block ciphers’ effects on quality of experience for VoIP unicast transmissions under different coding schemes (opens in a new tab)

  15. Metodologia de avaliação da segurança estrutural de pontes de concreto armado

    … da segurança de estruturas sendo, umas delas, o Rating Factor (RF). A reconstituição do projeto vem para sanar a ausência dos projetos estruturais originais, auxiliando na obtenção da resistência de projeto ( ), sendo que, alguns autores propõem fatores de redução da capacidade ( ) baseados na …

    brazil-ufv Repository record for Metodologia de avaliação da segurança estrutural de pontes de concreto armado (opens in a new tab)

  16. Structural Evaluation of SCDOT Prestressed Channel Bridges

    … nominal strength, cracking moment, distribution factor for moment, and dynamic load allowance. After completion of the channel test, a forensic investigation was carried out in which the end of the girder was chipped away to discover the actual strand properties and layout. Comparisons of the …

    clemson Repository record for Structural Evaluation of SCDOT Prestressed Channel Bridges (opens in a new tab)

  17. Risk-based bridge asset management

    … the structural risk of railway bridges by integrating once again structural reliability and exposure. Specifically, for the evaluation of the former for aging masonry arch railway bridges, which constitute a significant portion of the Italian railway infrastructure stock, a simplified approach …

    trento Repository record for Risk-based bridge asset management (opens in a new tab) Embargoed

  18. Comparative Study of LRFR and LFR Methods of Rating for Missouri Prestressed Bridges

    Bridge load rating is a crucial aspect of bridge evaluation and management, providing essential information regarding a bridge's capacity to safely accommodate traffic loads. For public safety, it is a crucial process for both new and existing bridges by establishing the weight restriction on heavy …

    umkc Repository record for Comparative Study of LRFR and LFR Methods of Rating for Missouri Prestressed Bridges (opens in a new tab)

  19. FIELD TEST AND ANALYSIS OF TWO PRESTRESSED CONCRETE BRIDGES AFTER DECK REPLACEMENT WITH FRP PANELS

    … most likely due to the diaphragms. The Impact Factor based on one set of experimental results was 1.217. However, for analysis the LRFD value of 1.33 was used. The Load Rating Factor for bridge B-0071 was 1.66 and for bridge B-0171 was 2.48 with the governing truck loading being the Design load …

    ohiolink Repository record for FIELD TEST AND ANALYSIS OF TWO PRESTRESSED CONCRETE BRIDGES AFTER DECK REPLACEMENT WITH FRP PANELS (opens in a new tab)

  20. Induction generators in mini and micro hydro applications as a low cost alternative

    … results in a balanced condition at a partial rating, and as a consequence considerable improvement in the de-rating factor is achieved. Alternatively extra reactive components are required to balance a single-phase load of the full three-phase rating. A generalized condition for balancing is …

    auckland-ms Repository record for Induction generators in mini and micro hydro applications as a low cost alternative (opens in a new tab)

Page 1 of 2