Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 30 for “"reactive current"”.
-
Integration of DERs Volt-Var Dynamic Constraint into Time-Coupled Optimal Power Flow for System Stability
… Although inverter-based DERs can provide fast reactive-power support through functions such as Volt–VAR control, conventional optimal power flow models generally represent these resources as static power injections. In addition, transmission-level dispatch commonly represents the downstream …
-
Application of motor capacitors to improve facility power usage in the industrial setting
… of capacitors at induction motors reduces the reactive current in the branch of the distribution system that supplies them. A reduction in the total current flowing to the motor along the distribution system results in smaller losses throughout the system. As losses diminish, the total real …
-
Intelligent STATCOM Voltage Regulation using Fuzzy Logic Control
Reactive power compensation is a very important and challenging task in electrical power systems today. Future trends foreseen in power systems such as high interconnectivity and the integration of renewable energy resources produce even more issues related to power system control and stability. …
-
Modelling, Control and Performance of Large-Scale Grid-Connected Solar Photovoltaic Power Plants Under Static and Dynamic Conditions Considering No Energy Storage
… grid code requirements including FRT capability, reactive power injection during voltage sags and power quality. From the GCPPP side, the main reasons for inverter disconnection are: loss of synchronization, excessive ac currents, excessive dc voltage, and voltage rise in non-faulty phases under …
-
Single Stage Grid-Connected Micro-Inverter for Photovoltaic Systems
… primary switch is achieved by allowing negative current from the grid-side through bidirectional switches placed on the secondary side of the transformer. Basically, the negative current discharges the MOSFET’s output capacitor thereby allowing turn-on of the primary switch under zero voltage. In …
-
Reactive power compensation using an energy management system
… costs and reduced energy efficiency is the reactive power demand on the grid. Inductive power demand reduces power factor, increases energy losses during transmission, limits real power supplied to the consumer, and results in higher costs to the consumer. Compensating for a reactive power …
-
Modular multilevel matrix converter for fractional frequency transmission in offshore wind power integration
… suffers from the disadvantage of high charging reactive current and therefore the maximum transmission distance is very limited. Fractional frequency transmission (FFT) is proposed to overcome this difficulty. With the offshore side operating at one third of the onshore grid frequency, the …
-
Feedforward/feedback control of an inverter-based compensator
… compensator used to achieve fast-acting reactive current compensation. Two feedforward schemes and five feedforward/feedback structures are analyzed. The first feedforward configuration uses phase-shift control (or simply [delta]-control) and results from shifting the fundamental …
-
Optimal capacitor placement for line-loss reduction and importance of voltage reduction during reactive power compensation and its effects on load, line loss, and generation
… was used to determine the capacitor sizes. After reactive power compensation voltage-dependent loads consume more power because of the increase in node voltage; therefore, customers pay more for their electricity while utilities experience savings from line-loss reduction. Therefore, a rationale …
-
Anti-islanding schemes for machine-based distributed generation
… recently proposed include the following: (A) Reactive error export detection (which controls the embedded generator excitation current so that it generates a known value of reactive current, which cannot be supported unless the generator is connected to the grid). (B) Fault level monitoring …
-
Power Converters for Electric Vehicles
… soft-switching for the power switches. Next, a current-driven full-bridge topology is proposed for the high-voltage DC/DC conversion stage, which guarantees soft-switching and eliminates voltage spikes across the output diodes. Also, two control approaches are proposed in order to improve the …
-
Investigating the Impact of Inverter-Based Resources on Power Grid Dynamics
… scheme enhances stability margins by modulating reactive current among the IBRs, as demonstrated through rigorous EMT simulations and validated in hardware testbeds. The results show that strategic coordination significantly improves both small-signal and large-signal stability. Furthermore, a …
-
Cascaded Inverters for Grid-Connected Photovoltaic Systems
… power theory is applied to generate the reactive current reference. Within the inverter’s capability, the local consumption of reactive power is provided to realize power factor correction. Then, the modular cascaded H-bridge multilevel inverter is connected to a three-phase utility …
-
MOSFET-based MMC for low-voltage DC distribution networks
… of cable voltage ratings, and elimination of reactive current and skin effect issues. LVDC distribution also complements the growth of power electronic loads having an implicit DC stage as part of their grid interface. However the DC-AC conversion stage at the customer end is one of the main …
-
Subthreshold resonance in central neurons
… with time- and voltagedependent membrane currents. In the present work, frequency-domain analyses of neocortical and thalamic neurons were performed to detect resonances at subthreshold potentials. The ionic mechanisms of these resonances and their effect on firing patterns were then …
-
Distance Protection of Systems with Inverter-based Resources
… resources (IBRs). A comprehensive dual current control scheme is proposed for IBRs during the low-voltage ride-through (LVRT) mode to address the challenges. This method addresses the shortcomings of existing solutions and enables correct operation of distance, directional, and …
-
Design and Comparison of passive component requirements of a matrix converter and voltage-source based back-to-back converter
… frequency switching ripple present in the input current of AC/AC pulse-width modulated (PWM) converters. Design of such filters requires an estimation of the higher harmonic components present in various voltages and currents. Due to pulse-width modulation (PWM), the matrix converter generates …
-
Voltage Stability Impact of Grid-Tied Photovoltaic Systems Utilizing Dynamic Reactive Power Control
Photovoltaic (PV) DGs can be optimized to provide reactive power support to the grid, although this feature is currently rarely utilized as most DG systems are designed to operate with unity power factor and supply real power only to the grid. In this work, the voltage stability of a power system …
-
EMTP-RV simulation of a chain link STATCOM
… is generally acknowledged as the next-generation reactive power controller in power systems. Its mode of operation is analogous to that of a rotating synchronous condenser and it provides dynamic voltage compensation, increased transient stability and damping for the power system. Several …
-
Control of voltage source converters connected to variable impedance grids
… is proposed. The PVD feeds forward the active current reference and measured voltage, and adapts the reactive current reference as a function of the impedance estimation, to pre-emptively compensate the local voltage for changes in active power transfer. This is justified through small signal …
Page 1 of 2