Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 8 of 8 for “"reduced scale experiments"”
-
Experimental and modeling study on the effect of opening location in the under-ventilated compartment fire
For compartment fires, a series of reduced-scale experiments and modeling were carried out in order to investigate how and why various opening location affects the compartment fire behaviors included: the temperature inside of the compartment (T_in), the external flame height (h_f), the heat …
-
Experimental investigations on fire behaviour and fire suppression in a reduced-scale room of the Castle of Chambord
L'état actuel de la protection contre les incendies par des systèmes sprinkler est non adapté à la protection des bâtiments et des monuments du patrimoine culturel. En effet, bien qu'il existe différents types de systèmes automatiques d'extinction d'incendie par sprinkler, leurs inconvénients …
-
Investigation of calcium orthophosphate chemical effects in a post-LOCA nuclear reactor containment
… debris accumulation at the sump pump screens. Experiments conducted on the bench scale show that the level of fiberglass destruction does not affect the concentration of calcium leached. Reduced-scale experiments were conducted on three solution inventory scales (0.5 L, 31.5 L, 1136 L) with …
-
Computational fluid dynamic analysis of hydrodynamic forces on inundated bridge decks and the effect of scaling
… fluid dynamic (CFD) simulations. The reduced scale experiments establish the foundations of validated computational practices to address the research needs of the transportation community. Three bridge deck types were used: a typical six-girder highway bridge deck, a three-girder deck, …
-
Optical and thermal radiative performance of bladed receivers for concentrating solar thermal energy systems.
… overall size of the bladed receiver cannot be reduced due to the tradeoffs. Thirdly, results from a detailed receiver model are presented, showing that a 2.5% increase in overall receiver efficiency could be expected from a bladed receiver adapted to a hypothetical 'high-performance PS10' …
-
Modeling, optimization and experimental assessment of transient-induced fatigue in hydraulic machines
… response and an experimental campaign on a reduced-scale model instrumented with strain gauges. The optimality of the sequences resulting from the optimization problem is validated experimentally, confirming the effectiveness of the quasi-steady-state approach for modeling transient crack …
-
Etude par similitude de l'influence du vent sur les transferts de masse dans les bâtiments complexes
Les bâtiments résidentiels et industriels munis d'un réseau de ventilation constituent des installations complexes, susceptibles d'être le siège de transferts de masse et d'énergie variés, selon les situations de fonctionnement. Afin d'étudier ces transferts de masse, une méthodologie permettant …
-
Experimental and numerical study of fire dynamics in air-tight buildings
… analysis and numerical studies. In terms of the reduced-scale NYX experiments: an extensive experimental campaign was designed and conducted at IRSN (French Institut de radioprotection et de Sûreté Nucléaire) to systematically study the influence of heat release rate (HRR) evolutions, mechanical …