  1. Development of a highly sensitive universal refractive index detector based on backscattering interferometry

    Refractive index (RI) detection is a common technique used in chemical and biochemical analyses. It can be employed to perform universal solute detection in micro-high performance liquid chromatography (ìHPLC), capillary electrophoresis (CE), as well as temperature measurements However, with …

    ttu Repository record for Development of a highly sensitive universal refractive index detector based on backscattering interferometry (opens in a new tab)

  2. The application of thin film planar waveguides as a refractive index detector for microscale high performance liquid chromatography

    … This device shows the feasibility of refractive index measurements in a flowing stream. Therefore, an online detector for High Performance Liquid Chromatography (HPLC) was chosen as the vehicle to test out the concepts. The research works were devoted to studies of waveguide properties …

    vt Repository record for The application of thin film planar waveguides as a refractive index detector for microscale high performance liquid chromatography (opens in a new tab)

  3. Instrumental and computational techniques for obtaining analytical data in high performance liquid chromatography

    … results are presented for HPLC systems using a refractive index detector;In HPLC, the limit of detection, as conventionally defined, becomes worse with increased retention due to band broadening. An integration method is presented and studied that overcomes this limitation, to a large extent, …

    iastate Repository record for Instrumental and computational techniques for obtaining analytical data in high performance liquid chromatography (opens in a new tab)

  4. Optimization of a Dynamic Hot Water Pretreatment of Switchgrass using Catalysis by Carbonation to Maximize Carbochemical Yields

    … HPX-87H column with a PDA (photo diode array) detector at wavelengths range of 210 and 280nm. Oligosaccharides were detected using Dionex HPLC employing Bio-Rad Aminex HPX-87P column using a Shodex RI-101 refractive index detector. The kinetics of the formation and degradation of HMF and …

    arkansas Repository record for Optimization of a Dynamic Hot Water Pretreatment of Switchgrass using Catalysis by Carbonation to Maximize Carbochemical Yields (opens in a new tab)

  5. Stratégie pour l’analyse qualitative et quantitative de sirops de céréales enrichis par voie enzymatique en isomaltooligosaccharides

    … de l’analyse quantitative L’HPLC-RID (Refractive Index Detector) utilisée avec une colonne Prevail Carbohydrate (Alltech), adaptée aux sucres de DP variables, s’est révélée être peu sélective du fait de l’obligation de travailler en conditions isocratiques. L’HPLC-ELSD (Evaporating …

    liege Repository record for Stratégie pour l’analyse qualitative et quantitative de sirops de céréales enrichis par voie enzymatique en isomaltooligosaccharides (opens in a new tab)

  6. Suitability of indigenous Saccharomyces cerevisiae strains isolated from spontaneous fermentations as wine fermentation starter cultures

    … performance liquid chromatography coupled to a refractive index detector (HPLC-RID), and volatile compounds were quantified by solid phase microextraction coupled to gas chromatography and mass spectrometry (SPME-GC/MS). After evaluation of their metabolite production and fermentation …

    ubc Repository record for Suitability of indigenous Saccharomyces cerevisiae strains isolated from spontaneous fermentations as wine fermentation starter cultures (opens in a new tab) Download PDF for Suitability of indigenous Saccharomyces cerevisiae strains isolated from spontaneous fermentations as wine fermentation starter cultures (opens in a new tab)

  7. Analytical applications of ultrasensitive polarization measurements

    … detection scheme superior to the conventional refractive index detector. Additionally, it will be shown that indirect polarimetry can be used to detect analyte absorptions with excellent sensitivity. The theoretical and experimental considerations necessary to obtain simultaneous selective, …

    iastate Repository record for Analytical applications of ultrasensitive polarization measurements (opens in a new tab)

  8. DYE ASSISTED HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC).

    … chromatography due to the lack of a universal detector. Refractive index detector, although a universal detector lacks sensitivity. The U.V. absorbance detector is the work horse of liquid chromatography. Its major drawback is its lack of universality. It is often desirable to extend the …

    arizona-thes Repository record for DYE ASSISTED HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC). (opens in a new tab)

  9. Laser-based optical activity detection of amino acids and proteins

    … growth in the past decade. The optical activity detector (OAD) for HPLC, previously developed in this research group, is a selective detector for optically active substances including amino acids and proteins. This dissertation illustrates the use of the OAD in three related areas;Section I …

    iastate Repository record for Laser-based optical activity detection of amino acids and proteins (opens in a new tab)

  10. Σχέσεις δομής και ιδιοτήτων πολυσακχαριτών σε συστήματα χαμηλής και υψηλής συγκέντρωσης διαλύτη

    … multiangle laser light scattering (MALLS) and a refractive index detector (RI). The isolation and purification of β-glucans from three different cereal genera (oat, barley and wheat) was carried out under mild conditions and involved successive enzyme digestions with a thermostable microbial …

    greece Repository record for Σχέσεις δομής και ιδιοτήτων πολυσακχαριτών σε συστήματα χαμηλής και υψηλής συγκέντρωσης διαλύτη (opens in a new tab)

  11. Synthesis of high molecular weight polymers as low-viscosity latex particles by RAFT aqueous dispersion polymerisation

    … a pH 7.0 TRIZMA buffer eluent combined with a refractive index detector. This technique indicated high chain extension efficiencies but broad molecular weight distributions (Mw/Mn ~ 1.5-2.5). The latter is consistent with the relatively low [RAFT agent]/[initiator] molar ratios required for …

    whiterose Download PDF for Synthesis of high molecular weight polymers as low-viscosity latex particles by RAFT aqueous dispersion polymerisation (opens in a new tab)

  12. Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-Poly(2-ethyl-2-oxazoline) Copolymers

    … multi-angle laser light scattering, viscometry, refractive index and UV spectroscopy to analyze block and graft copolymers as well as polymers with oligomeric molecular weights. Oligomeric molecular weights present special challenges since the light scattering and viscosity detectors are more …

    vt Repository record for Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-Poly(2-ethyl-2-oxazoline) Copolymers (opens in a new tab)

  13. The efficacy of sodium gluconate as a calcium lactate crystal inhibitor in Cheddar cheese.

    … HPLC externally equipped with a refractive index detector . The organic acids were detected using the UV detector set at 210 and 285 nm, and the refractive index was used for quantification of lactose. The results indicated that at 1-week of ripening, Cheddar cheeses with a higher …

    umn Repository record for The efficacy of sodium gluconate as a calcium lactate crystal inhibitor in Cheddar cheese. (opens in a new tab)

  14. Analýza hlavních sacharidů vína

    Diplomová práce se zabývá stanovením hlavních sacharidů vína. Teoretická část se věnuje výrobě vína od samotného hroznu až po ošetřování a školení vína. Zmiňuje se také o sacharidech ve víně, hlavně glukóze a fruktóze. Práce poskytuje přehled dostupných literárních pramenů o možnostech stanovení …