Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"relative calibration"”.
-
Intercalibration of QuikSCAT and OSCAT Land Backscatter
… the time series requires careful cross-calibration of the two sensors. Because the sensor datasets overlapped by only a few weeks in late 2009, the amount of simultaneous data is insufficient to describe temporal and locational variations in the relative calibration, or difference …
-
Measurement of the calorimetric energy scale in MINOS
… Such a comparison depends on the accuracy of the relative calorimetric energy scale.</p> <p>This thesis details a precise measurement of the calorimetric energy scale of the MINOS Far detector and Calibration detector using stopping muons with a new "track window" technique. These measurements are …
-
Relative Radiometic Characterization and Correction of the Landsat 8 OLI Using the On-Orbit Side-Slither Maneuver
… leading to a need to have other working relative calibration methods in reserve. The purpose of this thesis is to validate the use of a secondary relative calibration method for the first eight bands of the OLI called the side-slither maneuver. By rotating a pushbroom sensor 90 degrees on …
-
A saturation calibration of Hamamatsu’s multi-pixel photon counter
A relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small model …
-
DESIGN, DEVELOPMENT, AND TESTING OF AN INVERTED PENDULUM THRUST STAND FOR LOW POWER HALL-EFFECT THRUSTERS
… thrust of a low-power Hall-effect thruster. The calibration system and control algorithm are described along with the atmosphere testing conducted prior to testing in vacuum. This thrust stand was tested in vacuum with an Aurora Hall-effect thruster, and the performance of the calibration …
-
Hyperspectral Imaging System Model Implementation and Analysis
… collection. Results include the use of large calibration panels to show the predicted radiance consistent with the collected data. Grass radiance predicted from ground truth reflectance data also compare well with the real world collected data, and an eigenvector analysis also supports the …
-
Relative Infrasound Calibration of Microphones with Application to Outdoor Vector Intensity Measurements
… effects on humans is intended for performing a relative calibration. This work also seeks to elaborate recommendations for probe spacing, averages or length recordings, and instrument mismatch. The last two chapters show the PAGE method application in infrasonic sources. Those chapters have the …
-
The calibration of a portable induction magnetometer system
… and the filter capacitors. Two methods of relative calibration for the induction magnetometer system give reliable response curves. One method uses a Wheatstone bridge. The sensor is one arm of the bridge and it is shown that the effect of the signal generator is the same as if the coil was …
-
Vicarious Methodologies to Assess and Improve the Quality of the Optical Remote Sensing Images: A Critical Review
… kinds of optical satellites which lacks on-board calibration system. In this article, image quality categories have been explored, and essential quality parameters (e.g., absolute and relative calibration, aliasing, etc.) have been identified. For each of the parameters, appropriate …
-
Evaluation of a CCD camera system for BRDF retrieval for remote sensing applications for vicarious calibration
… (BRDF) data has been evaluated for vicarious calibration applications. This evaluation is done by assessing the calibration requirements necessary to retrieve BRDF data for the improvement of the vicarious calibration approach, and then by examining the calibration problem itself. A …
-
The characterization and calibration of the OSIRIS infrared imager
… from atmospheric scattering and emission. A full calibration of the imaging system is required to remove all instrument dependent effects that modify the observations. This work presents the characterization and calibration of the OSIRIS imaging system in an attempt to produce observations that …
-
The Upgrade, Calibration and Evaluation of the Multi-Slit OSIRIS-DM for Stratospheric Balloon Flight
… instrument was undertaken through laboratory calibrations and limb scatter measurement collection. The calibration process includes a wavelength registration, a spectral point spread function analysis, a relative calibration and an absolute calibration, all performed with laboratory equipment. …
-
Investigating the mesh dependency and upscaling of 3D grain-based models for the simulation of brittle fracture processes in low-porosity crystalline rock
… using various Voronoi and tetrahedral GBMs. Relative calibration requirements are outlined to generate similar macro-strength and damage profiles for all the models. The results confirmed a number of inherent model behaviors that arise due to mesh dependency. In Voronoi models, inherent …
-
Frequency-domain Calibration of LiDARs: An online method for extrinsic calibration of LiDAR sensors on marine vessels using IMU data and frequency analysis
… boat operations rely on accurate extrinsic calibration. Current practice requires manual measurement of each LiDAR’s position and orientation (pose), which is time-consuming and must be repeated if a sensor is displaced during operation. This thesis presents an online and target-less method …
-
A New Method for Melt Detection on Antarctic Ice-Shelves and Scatterometer Calibration Verification
… events, among others. In order to verify the relative calibration of these two sensors a simple cross-calibration method is implemented based on land measurements. A first-order polynomial model for the incidence angle dependence of sigma-0 is used to account for biases in the sigma-0 …
-
Cosmology as a Laboratory for New Physics
… <br/><br/>The second part addresses the calibration of cosmic microwave background polarisation experiments. Absolute calibration of the polarisation angle is a critical systematic for searches for parity violation, such as cosmic birefringence, where a true physical rotation of the …
-
Calibration and validation the Dynamic Photorefraction System (DPRS)
… that varies with the degree of ocular defocus relative to camera. However, this gradient can be influenced by various factors such as pupil size, fundus brightness etc. Thus the relationship between defocus and the intensity gradient must be calibrated empirically in order that valid measures …
-
An Updated Radiometric Calibration of the Hyperion Sensor
… the EO-1 Hyperion, by first performing cross calibration with a multispectral sensor, the Landsat 7 ETM+, and then absolute radiometric calibration using the reflectance based approach of vicarious calibration. The test site used for the characterization of the Hyperion sensor is a region …
-
Landsat-4/5 Band - 6 Characterization
… NASA/Goddard Space Flight Center, was to provide calibration of the Landsat TM thermal band. Relative radiometric responses for Thematic Mapper {TM) band 6 data from Landsat- 4 and Landsat-5 were analyzed and an algorithm has been developed that significantly reduces the striping in Band 6 images …
-
Grasp-sensitive surfaces
… electronics knowledge. For FlyEye I developed a *relative calibration* algorithm that allows determining the locations of groups of sensors whose arrangement is not known. **TDRtouch** extends Time Domain Reflectometry (TDR), a technique traditionally used for inspecting cable faults, for touch …