Showing 1 to 8 of 8 for “"relative electron density"”.

  1. Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision

    … index measure, difference signal-to-noise ratio, relative electron density drift, and radiomics deltas. Results: Across the evaluated cases, dose agreement was high and the gamma analysis passed. Hounsfield-unit mean absolute error was below 50 HU in many cases, structural similarity was close to …

    vcu Repository record for Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision (opens in a new tab)

  2. Οστεολυτικές μεταστάσεις: συγκριτική μελέτη διαφορετικών σχημάτων ακτινοθεραπείας σε σχέση με την απεικονιστική και κλινική ανταπόκριση

    … a parameter that can be assessed by using the Relative Electron Density (RED) in computed tomography images. Treatment response should be based on objective criteria. The aim of this study was to compare the three most commonly used fractionation schedules for bone metastasis using both …

    greece Repository record for Οστεολυτικές μεταστάσεις: συγκριτική μελέτη διαφορετικών σχημάτων ακτινοθεραπείας σε σχέση με την απεικονιστική και κλινική ανταπόκριση (opens in a new tab)

  3. Plasma Dynamics Using Ion Doppler Spectroscopy in HIT-SI3

    … to the inner wall along the major radius for relative density, temperature, and ion flow velocity. The profiles are then compared to magnetohydrodynamic (MHD) simulation. Time-dependent analysis show coherent sinusoidal bulk motion that is locked to the frequency of the injector perturbations …

    washington Repository record for Plasma Dynamics Using Ion Doppler Spectroscopy in HIT-SI3 (opens in a new tab)

  4. Langmuir Probe Measurements in the Ionosphere

    … Ionosphere (IRI) model, while the derived density matches better with the USU-Global Assimilation of Ionospheric Measurement model. The third paper presents the dataset from the EQUIS II sounding rocket campaign. The rocket payloads carried a PIP, a DCP, and an internally heated Sweeping …

    utahstate Repository record for Langmuir Probe Measurements in the Ionosphere (opens in a new tab)

  5. Architecture, Modeling, and Analysis of a Plasma Impedance Probe

    Variations in ionospheric plasma density can cause large amplitude and phase changes in the radio waves passing through this region. Ionospheric weather can have detrimental effects on several communication systems, including radars, navigation systems such as the Global Positioning Sytem (GPS), …

    utahstate Repository record for Architecture, Modeling, and Analysis of a Plasma Impedance Probe (opens in a new tab)

  6. Physics and Geometry Input-Based Neural Network Dose Engine with Control Point Input Generator

    … the dose matrix and HU values also converted to relative electron density and physical density. MC calculations with CP geometry were used as ground truth. Finally, a transformer network architecture was trained on the mapping, y=f(x,r), where x represents the physical density, r represents the …

    buffalo Repository record for Physics and Geometry Input-Based Neural Network Dose Engine with Control Point Input Generator (opens in a new tab)

  7. Dual energy image reconstruction and systems for application in proton therapy treatment planning

    … be known. This parameter is dependent on the electron density and effective atomic number of the material and describes the energy loss per unit length in the tissue. In current clinical practice, the SPR of patient tissues is obtained through single energy CT (SECT) scanning. The SECT scan …

    adelaide Repository record for Dual energy image reconstruction and systems for application in proton therapy treatment planning (opens in a new tab)

  8. Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system

    … extracting effective atomic number (Zeff) and relative electron density (ρe) of tissues. We demonstrated that the method with PCD-CT was more accurate in extracting Zeff and ρe for a set of electron density phantom materials with known Zeff and ρe than the method with DECT. In addition, four …

    uvic Repository record for Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system (opens in a new tab)