Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"relaxation T1"”.

  1. METHODS FOR QUANTITATIVE SUSCEPTIBILITY MAPPING AND ITS APPLICATION TO CARDIOVASCULAR MRI

    … contrasts mechanisms such as proton spin relaxation (T1, T2, etc.), proton motion (diffusion, perfusion, flow, etc.), and molecular electron cloud polarization (magnetic susceptibility). This dissertation focuses on the tissue magnetic susceptibility, and the technique for the mapping of …

    cornell Repository record for METHODS FOR QUANTITATIVE SUSCEPTIBILITY MAPPING AND ITS APPLICATION TO CARDIOVASCULAR MRI (opens in a new tab)

  2. Relaxation of longitudinal and singlet nuclear spin order as a function of solvent viscosity

    … of spin magnetization is limited by longitudinal relaxation (T1) which brings the magnetization back to equilibrium within a few seconds. The conversion of longitudinal into singlet order can extend that lifetime to tens of minutes up to an hour.<br/>Most nuclear spin relaxation mechanisms in …

    soton Download PDF for Relaxation of longitudinal and singlet nuclear spin order as a function of solvent viscosity (opens in a new tab)

  3. Methods for Accelerated Quantitative Abdominal MRI

    … significant patient risk. The tissue parameters T1-relaxation (T1), proton density fat-fraction (PDFF), and R2*-relaxation (R2*) have shown utility for comprehensive liver assessment. This work aims to accelerate the process of acquiring these parameters. We first develop a deep-learning …

    arizona-thes Repository record for Methods for Accelerated Quantitative Abdominal MRI (opens in a new tab)

  4. T1 mapping and image reconstruction: examination for quantitative MRI

    … are particularly interested in those related to relaxation, i.e., the process of protons returning to the original state from an excited state. There are two relaxation mechanisms in MRI, namely transverse relaxation and longitudinal relaxation, concerned with the transverse and longitudinal …

    jhu Repository record for T1 mapping and image reconstruction: examination for quantitative MRI (opens in a new tab)

  5. Nuclear Magnetic Resonance with the Distant Dipolar Field

    … of DDF-based sequences in the presence of relaxation (T1 and T2) and diffusion. A general introduction to magnetic resonance phenomenon is followed by a more in depth introduction to the DDF and its effects. A novel analytical signal equation has been developed to describe the effects of T2 …

    arizona-thes Repository record for Nuclear Magnetic Resonance with the Distant Dipolar Field (opens in a new tab)

  6. Investigations into magnetic relaxation for vanadium complexes

    … of these metal complexes, spin-lattice relaxation (T1) and phase memory relaxation (Tm or T2). Investigation of these parameters and fitting of these parameters provided information of how the local environment played a role in shortening these lifetimes. The complexes developed in this …

    colostate Repository record for Investigations into magnetic relaxation for vanadium complexes (opens in a new tab)

  7. Multiscale Transport and Dynamics in Ion-Dense Organic Electrolytes and Copolymer Micelles

    … dynamics. In particular, I present spin-lattice relaxation (T1) results that directly measure single chain exchange rate kexch between micelles and diffusion results that inform on the unimer exchange mechanism. These convenient NMR methods thus offer an economical alternative (or complement) to …

    vt Repository record for Multiscale Transport and Dynamics in Ion-Dense Organic Electrolytes and Copolymer Micelles (opens in a new tab)

  8. Understanding the benefits and limitations of magnetic nanoparticle heating for improved applications in cancer hyperthermia and biomaterial cryopreservation

    … correlate with reductions in longitudinal relaxation (T1) measured by sweep imaging with Fourier transformation (SWIFT) magnetic resonance imaging (MRI), providing a potential platform to account for these aggregation effects and directly predict heating in a clinical setting.Finally, we …

    umn Repository record for Understanding the benefits and limitations of magnetic nanoparticle heating for improved applications in cancer hyperthermia and biomaterial cryopreservation (opens in a new tab)

  9. Characterizing magnetization exchange in healthy human brain and bovine brain

    Multi component T₂ relaxation imaging is an established MRI technique for measuring myelin water (MW, water molecules trapped between myelin sheath bilayers). Myelin water fraction (MWF, the fraction of central nervous system water with a short T₂) has been quantitatively correlated to histological …

    ubc Repository record for Characterizing magnetization exchange in healthy human brain and bovine brain (opens in a new tab) Download PDF for Characterizing magnetization exchange in healthy human brain and bovine brain (opens in a new tab)

  10. Robust Magnetic Resonance Imaging of Short T2 Tissues

    Tissues with short transverse relaxation times are defined as ‘short T2 tissues’, and short T2 tissues often appear dark on images generated by conventional magnetic resonance imaging techniques. Common short T2 tissues include tendons, meniscus, and cortical bone. Ultrashort Echo Time (UTE) pulse …

    sask Repository record for Robust Magnetic Resonance Imaging of Short T2 Tissues (opens in a new tab)

  11. Established and Emerging Cardiovascular Magnetic Resonance Imaging Techniques in the Evaluation of Subclinical Cardiovascular Disease

    … Aims: To assess 1) whether blood longitudinal relaxation (T1) can be used to estimate blood haematocrit value to allow calculation of extracellular myocardial volume fraction (ECV), 2) whether CMR feature tracking (CMR-FT) is a feasible means of assessing aortic stiffness, 3) whether global …

    whiterose Download PDF for Established and Emerging Cardiovascular Magnetic Resonance Imaging Techniques in the Evaluation of Subclinical Cardiovascular Disease (opens in a new tab)

  12. Development of Low Frequency Electron Paramagnetic Resonance Methods and Instrumentation for Biological Applications

    … and field jumps to measure electron spin lattice relaxation (T1) at 1 GHz. Overall good agreement of the relaxation times was observed between the new methods and conventional techniques. However, the uncertainty associated with the rapid scan method is greater due to the low number of points that …

    denver Repository record for Development of Low Frequency Electron Paramagnetic Resonance Methods and Instrumentation for Biological Applications (opens in a new tab)

  13. Monitoring dynamically the gelation phase transition of agarose with T2 qMRI as a function of concentration at 3T

    … transition of agarose solutions with transverse relaxation (T2) quantitative magnetic resonance imaging (qMRI). The focus is on the reduction of T2 of agarose solution upon gelation. The sol-to-gel phase transition of agarose may provide a useful and controllable experimental model of tissue …

    bu Repository record for Monitoring dynamically the gelation phase transition of agarose with T2 qMRI as a function of concentration at 3T (opens in a new tab)

  14. Block Copolymer Solutions: Transport and Dynamics, Targeted Cargo Delivery, and Molecular Partitioning and Exchange

    … we developed – time-resolved NMR spin-lattice relaxation (T1) or TR-NMR. This technique is an analog to time-resolved small-angle neutron scattering (TR-SANS), which can monitor specific signal intensity changes caused after mixing of isotope-labeled micelle solutions. A second system, …

    vt Repository record for Block Copolymer Solutions: Transport and Dynamics, Targeted Cargo Delivery, and Molecular Partitioning and Exchange (opens in a new tab)

  15. Nuclear Spin Dynamics Under Above-Bandgap Optical Pumping in Silicon

    … 29Si nuclear spins have long spin-lattice relaxation times compared to experimental timescales, providing a thermally isolated system whose effective temperature (polarization) can be controlled. This can serve as a test-bed for studying central spin effects and other many-body experiments. …

    waterloo Repository record for Nuclear Spin Dynamics Under Above-Bandgap Optical Pumping in Silicon (opens in a new tab)

  16. Secondary relaxation processes in neat and binary glass formers studied by 2H NMR spectroscopy

    … base circle of a cone, i.e. also the secondary relaxation is not significantly affected by the translational symmetry of the PC phase. As alpha- and beta-process do not merge in cyanocyclohexane, pronounced effects were observed at high temperatures: for the first time an additional minimum in …

    bayreuth Repository record for Secondary relaxation processes in neat and binary glass formers studied by 2H NMR spectroscopy (opens in a new tab)

  17. Měření relaxačních konstant technikami magnetické rezonance

    … a IR- inversion recovery) relaxačních časů T1, T2 případně T2*. Chceme-li měřit relaxační dobu T2, stačí sejmout FID signál po aplikaci 90° RF impulzu. Relaxační čas T2* získáme z absorpční čáry. Pro měření transverzální relaxace T2 se dají aplikovat metody spinového echa (někdy také …

    brno-tech Repository record for Měření relaxačních konstant technikami magnetické rezonance (opens in a new tab)

  18. A Time-efficient Method for Accurate T1 Mapping of The Human Brain

    … in order to improve the accuracy of quantitative T1 mapping of the human brain. Several optimized post-processing algorithms have been studied and compared in terms of their T1 mapping accuracy. The modified multipoint two-parameter fitting method was found to produce less underestimation compared …

    vcu Repository record for A Time-efficient Method for Accurate T1 Mapping of The Human Brain (opens in a new tab)

  19. T1 und T2*-Quantifizierung in der menschlichen Lunge

    … Lunge optimierte Methoden zur Bestimmung von T1- und T2*-Karten diskutiert: Dc-Gating ermöglicht die Quantifizierung in freier Atmung, wobei für die T1-Quantifizierung mittels Inversion Recovery eine Korrektur des dc-Signals entwickelt wurde. Dies hat den Vorteil, dass Parameterkarten aus …

    wurz-thes Repository record for T1 und T2*-Quantifizierung in der menschlichen Lunge (opens in a new tab)