Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"remote powering"”

  1. Remote Powering of Wireless IoT Nodes

    Le monde connaît un intérêt croissant pour l'IoT (Internet des Objets) et de l'écosystème qui y est rattaché. Afin de minimiser l'impact environnemental et les coûts de maintenance rattachés à ces noeuds, il est nécessaire de les alimenter en excluant l'usage de piles et des batteries, pour des …

    star-france Repository record for Remote Powering of Wireless IoT Nodes (opens in a new tab)

  2. Remote Powering and Wireless Communication of a Smart Knee Prosthesis

    … of the implanted electronics. However while remote powering is already an issue, further increasing the power consumption becomes more challenging. On the other hand, with the development of better tools, such as complex field solvers, it is easier to perform more complex analyses. This helps …

    epfl Repository record for Remote Powering and Wireless Communication of a Smart Knee Prosthesis (opens in a new tab)

  3. Remote Powering and Communication of Implantable Biosensors Through Inductive Link

    … to provide power, data communication and remote control to the implantable biosensor. High wearability of the transmitting unit, low invasivity of the implanted electronics, integration of the power management module within the sensor, and a reliable communication protocol with portable …

    epfl Repository record for Remote Powering and Communication of Implantable Biosensors Through Inductive Link (opens in a new tab)

  4. Remote powering and signalling using photovoltaic power converter and reflective electroabsorption modulator

    … to conventional electrical power delivery. In remote access networks, photovoltaic power converter (PPC) and modulators are key components for enabling both power and data transfer over fiber. A POF link offers immunity to electromagnetic interference while providing reliable, high-resolution …

    cork Repository record for Remote powering and signalling using photovoltaic power converter and reflective electroabsorption modulator (opens in a new tab)

  5. Miniaturized, Directional Antennas For Wireless Power Transfer

    … us the ability to stay connected in all but the remotest places on earth. However, one limiting factor to new wireless technologies has always been the battery. In this thesis the prospect of wireless power transfer for use in the remote powering of wireless devices is explored. First a UHF …

    gsu Repository record for Miniaturized, Directional Antennas For Wireless Power Transfer (opens in a new tab)

  6. Design and prototype development of a wireless power transmission system for a micro air vehicle (MAV)

    … at 1.0 GHz and 1.3 GHz is used to demonstrate remote powering of a micro air vehicle (MAV). Several prototype microwave rectifier systems were fabricated in microstrip using EEsof(registered) computer aided engineering (CAE) software to assist in their design. Radio frequency (RF) parameters of …

    nps Repository record for Design and prototype development of a wireless power transmission system for a micro air vehicle (MAV) (opens in a new tab)

  7. Wireless Power Transfer and Data Communication for Implantable Autonomous Monitoring and Detection of Epilepsy In Vivo

    … battery. A 4-coil inductive link is used for remote powering. A stable and ripple free supply voltage for the implanted system is generated by the use of active half-wave rectifier and low drop-out regulator blocks. Additionally, the automatic resonance tuning mechanism is developed to …

    epfl Repository record for Wireless Power Transfer and Data Communication for Implantable Autonomous Monitoring and Detection of Epilepsy In Vivo (opens in a new tab)

  8. Remotely Powered Wireless Cortical Implants for Brain-Machine Interfaces

    … to the patient. Another common method of powering is to utilize batteries in the implant. Nevertheless, this method is not desirable as the batteries have to be replaced at the end of their lifetime with a surgical procedure. This thesis presents the development of a remotely powered …

    epfl Repository record for Remotely Powered Wireless Cortical Implants for Brain-Machine Interfaces (opens in a new tab)

  9. Remotely powered underwater acoustic sensor networks

    … harvesting is a promising solution, in which Remotely Powered UASN (RPUASN) nodes harvest and store the power available from a powerful external underwater acoustic source. In this study, the novel RPUASN paradigm is introduced and developed. The characteristics of the power harvested from the …

    metu Repository record for Remotely powered underwater acoustic sensor networks (opens in a new tab)

  10. An implantable biosensor array for personalized therapy applications

    … was then integrated with a CMOS circuit and a remote powering coil for the realization of a fully implantable device. The assembled system has been packaged with an inner moisture barrier in parylene C, to prevent circuit corrosion and toxic metals leaking, and an external biocompatible …

    epfl Repository record for An implantable biosensor array for personalized therapy applications (opens in a new tab)

  11. Self-folding 3D micro antennas for implantable medical devices

    … device miniaturization. However, alternative powering methods, such as electromagnetic waves, do not rely on stored energy and are capable of providing high energy densities per unit of area, thus increasing the potential for device miniaturization. Hence, we envision an implanted medical …

    minho-thes Repository record for Self-folding 3D micro antennas for implantable medical devices (opens in a new tab)

  12. Implantable Multi-panel Platform for Continuous Monitoring of Exogenous and Endogenous Metabolites for Applications in Personalized Medicine

    … electrochemical measurements; a coil for remote powering of the integrated circuit and the short-range data transmission to an external device; a membrane packaging ensuring measurements with high signal-to-noise ratio, biocompatibility and selectivity against possible interfering …

    epfl Repository record for Implantable Multi-panel Platform for Continuous Monitoring of Exogenous and Endogenous Metabolites for Applications in Personalized Medicine (opens in a new tab)

  13. Contributions to the design of an underwater Rfid Reader/Tag Software Transceiver

    … multiple tags (transponders), which are powered remotely and retrieve the information from wireless low power and low size sensors implanted in the living fish. The focus of this work is set on two main pillars and so is this work structured. The first part of this thesis covers the …

    ulpgc Repository record for Contributions to the design of an underwater Rfid Reader/Tag Software Transceiver (opens in a new tab)

  14. Analysis and optimization of passive UHF RFID systems

    … identification method, relying on storing and remotely retrieving data using devices called RFID tags or transponders. An RFID tag is a small object that can be attached to or incorporated into a product, animal or person. RFID tag contains antenna to enable it to receive and respond to …

    epfl Repository record for Analysis and optimization of passive UHF RFID systems (opens in a new tab)

  15. Integrated Wireless Power, Data Communication, and Thermal Sensing System for Autonomous Multisite Brain Implants

    … replacement issues, and the complexity of wired powering. Wireless power transmission (WPT) methods have been employed to transfer wireless power and data between the implanted units and an external medical unit. Ultrasonic, capacitive, optical, radio frequency, and inductive links are the most …

    epfl Repository record for Integrated Wireless Power, Data Communication, and Thermal Sensing System for Autonomous Multisite Brain Implants (opens in a new tab)

  16. Passive UHF RFID Systems for Capacitive Sensing Applications

    … and their performance is characterized. The remote powering subsystem consists of the tag antenna and the rectifier. Measurement results showed a maximum power conversion efficiency of 65% for the antenna-rectifier pair operated at 866 MHz. The rectifier is a three-stage, differential …

    epfl Repository record for Passive UHF RFID Systems for Capacitive Sensing Applications (opens in a new tab)

  17. Deeply implanted medical device based on a novel ultrasonic telemetry technology

    … Key features of the proposed system include remote powering of the implanted device and communication with an external Control Unit (CU) by backscattering modulation. For both energy and data transfer, an ultrasonic carrier is used instead of Electromagnetic (EM) waves because it is …

    epfl Repository record for Deeply implanted medical device based on a novel ultrasonic telemetry technology (opens in a new tab)

  18. Monitoring switch-type sensors and powering autonomous sensors via inductive coupling: application to removable seats in vehicles

    … of the seat detectors from a readout unit and 2) remote power transmission to a detection unit and subsequent data transmission by a wireless transceiver. Inductive links have been widely proposed for sensors placed in harsh or inaccessible environments, where wiring is unpractical. Usually, the …

    barcelona Repository record for Monitoring switch-type sensors and powering autonomous sensors via inductive coupling: application to removable seats in vehicles (opens in a new tab)

  19. Design, characterisation and optimisation of a SAW correlator driven, wireless, passive microvalve for biomedical applications.

    … implantable devices. However, the lifetime and remote interrogability of implants, specifically used for drug delivery applications, has been an issue of contention, as their deployment period is limited by the battery life and the device size. Furthermore, not much research effort is directed …

    adelaide Repository record for Design, characterisation and optimisation of a SAW correlator driven, wireless, passive microvalve for biomedical applications. (opens in a new tab)

Page 1 of 2