Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"replica-technique"”.

  1. Indium replica for metallurgical examination

    … purpose of this work was to discover a feasible technique for making metallurgical examinations of highly radioactive samples. The solution of this problem was sought through the use of a replica technique.

    nps Repository record for Indium replica for metallurgical examination (opens in a new tab)

  2. Slip line studies in deformed ordered and disordered Cu3Au single crystals

    … via optical metallography and by the two-step replica technique and subsequent examination in the electron microscope. Typical macroscopic stress-strain curves for each type of crystal have been noted as well as the change of specimen axis orientation with deformation. The crystals were …

    rice Repository record for Slip line studies in deformed ordered and disordered Cu3Au single crystals (opens in a new tab)

  3. Studies of Helicoidal wall formation and organization in Nitella : [a thesis] ...

    … electron microscopy in thin sections and by the replica technique. Removal of microtubules in very young cells had a randomizing effect on cellulose organization, but absence of microtubules or their rearrangement did not prevent the formation of secondary walls with characteristic helicoidal …

    u-pacific Repository record for Studies of Helicoidal wall formation and organization in Nitella : [a thesis] ... (opens in a new tab)

  4. Development of novel series and parallel sensing system based on nanostructured surface enhanced Raman scattering substrate for biomedical application

    … different areas, especially biological sensing techniques. One of the promising biological sensing applications by surface resonance polariton is surface enhanced Raman spectroscopy (SERS), which significantly reinforces the feeble signal of traditional Raman scattering by at least 104 times. It …

    uiuc Repository record for Development of novel series and parallel sensing system based on nanostructured surface enhanced Raman scattering substrate for biomedical application (opens in a new tab)

  5. Marginal Fit of Lithium Disilicate Crowns using Three Different Fabrication Techniques

    … McX and McX5, and differed in their fabrication technique. The Pressed group was fabricated with IPS e.max Press and was heat pressed with the lost wax technique. Both of the CAD/CAM milled restorations McX and McX5 were scanned and designed using the same process and differed only in the milling …

    tamu Repository record for Marginal Fit of Lithium Disilicate Crowns using Three Different Fabrication Techniques (opens in a new tab)

  6. Development of a synthetic trabecular bone graft utilizing a two phase glass-ceramic

    … mimicked human trabecular bone through the foam replica technique. Parent glasses were formed via a melt quench route to produce glass frits, these were then processed into powders consisting of <45 µm particles confirmed through particle analysis. DSC analysis confirmed a glass transition region …

    whiterose Download PDF for Development of a synthetic trabecular bone graft utilizing a two phase glass-ceramic (opens in a new tab)

  7. Effect of Firing on the Marginal Fit of Heat-Pressed Lithium Disilicate Veneers: An in-vitro study

    … fabricated with the “staining”, or “cut-back” technique, using 3D analysis. Two groups of ten specimens were fabricated and each group differed in core thickness and the fabrication process. Group S was a full contour veneer, with one glaze firing. Group CB had a “cut-buck” core of 0.6mm on the …

    tamu Repository record for Effect of Firing on the Marginal Fit of Heat-Pressed Lithium Disilicate Veneers: An in-vitro study (opens in a new tab)

  8. In Situ Diffraction Experiments and Multiscale Mechanics Modeling of Fatigue Behavior in Mg Alloys

    … than the macroscopic measurements based on replica technique and the small-scale mechanical testing that cannot easily provide a complete view on the synergy of many scale-dependent deformation and failure mechanisms.</p> <p>The primary objective aims to identify the roles of the deformation …

    utk-theses Repository record for In Situ Diffraction Experiments and Multiscale Mechanics Modeling of Fatigue Behavior in Mg Alloys (opens in a new tab)

  9. Novel bioceramic materials for the synthesis of scaffolds towards dental tissue regeneration

    … ZnO/CuO/SrO2 were developed through the foam replica technique and studied with a number of techniques to determine their apatite forming ability, degradation rates, porosity and mechanical strength. Powder samples were thermally characterized before the scaffold fabrication with Thermal …

    greece Repository record for Novel bioceramic materials for the synthesis of scaffolds towards dental tissue regeneration (opens in a new tab)

  10. Characterization and biosynthesis of mitochondrial proteins

    … protein serum and analysed by the immune-replica technique However, a preliminary experiment in the yeast rho- strain (rho) , which can accumulate large quantities of mitochondrial precursors in the presence of uncoupler, indicated that the protein was probably not. made as a larger Mr …

    glasgow Download PDF for Characterization and biosynthesis of mitochondrial proteins (opens in a new tab)

  11. An electron fractography (SEM)investigation of heat-affected zone in the newly developed Climax low-carbon Mn-Mo-Nb Steel

    … this new steel was investigated via the Gleeble technique. The grain refined region of the heat-affected zone showed excellent toughness at impact test temperatures of as low as -60&deg;F, the upper-shelf extending to about -25&deg;F. The grain coarsened region showed inferior toughness, even at …

    ut-knoxville Repository record for An electron fractography (SEM)investigation of heat-affected zone in the newly developed Climax low-carbon Mn-Mo-Nb Steel (opens in a new tab)

  12. Study of the kinetics of precipitation, dissolution and coarsening of aluminum nitride in low carbon steels

    … been used, with the aid of the carbon extraction replica technique, to relate the observed morphologies, spatial distribution and particle size distribution of A1N precipitates in a low carbon, Al-killed steel to their thermal history. Experimental studies have been conducted on the precipitation, …

    ubc Repository record for Study of the kinetics of precipitation, dissolution and coarsening of aluminum nitride in low carbon steels (opens in a new tab) Download PDF for Study of the kinetics of precipitation, dissolution and coarsening of aluminum nitride in low carbon steels (opens in a new tab)

  13. Structural and functional studies on two mitochondrial proteins: The pyruvate dehydrogenase complex and the phosphate carrier

    … was further investigated using the immune-replica technique. (B) Topographical and biosynthetic studies on phosphate transport protein (PTP). For these studies high-titre monospecific antiserum was produced against the purified phosphate transport protein from rat liver. This antiserum was …

    glasgow Download PDF for Structural and functional studies on two mitochondrial proteins: The pyruvate dehydrogenase complex and the phosphate carrier (opens in a new tab)

  14. Marginal Gap and Internal Fit of a Zirconia Crown and Implant Abutment using Three Different Digital Workflows

    … Microscope (SEM). Secondly by a silicone replica technique and Geomagic software. Group results were compared while concurrently validating the Geomagic measuring protocol as outlined within the study. A Kruskal-Wallis test was administered followed by post-hoc Mann-Whitney tests with …

    tamu Repository record for Marginal Gap and Internal Fit of a Zirconia Crown and Implant Abutment using Three Different Digital Workflows (opens in a new tab)

  15. Einfluss unterschiedlicher Modellmaterialien auf die Dimensionsstabilität, Scan-Eignung und Abriebfestigkeit im CAD/CAM-Herstellungsprozess mehrgliedriger Brücken

    Ziel: Seit Einführung der digitalen Abformungen in den computer-aided design (CAD)/ computer-aided manufacturing (CAM)-Workflow besteht großes Interesse an Untersuchungen zur Passgenauigkeit der damit gefertigten Restaurationen sowie der Genauigkeit von Intraoralscannern. Modelle für derartige …

    fu-berlin Repository record for Einfluss unterschiedlicher Modellmaterialien auf die Dimensionsstabilität, Scan-Eignung und Abriebfestigkeit im CAD/CAM-Herstellungsprozess mehrgliedriger Brücken (opens in a new tab)

  16. Desempenho clínico, discrepância marginal e interna de coroas monolíticas de zircônia ultratranslúcida, ensaio clínico controlado e randomizado: em até 2 anos

    … were selected for ID and MD evaluation using the replica technique. The internal part of each crown was filled with a light-bodied addition silicone (X-light, 3M ESPE), followed by a small portion of heavy-bodied silicone (Express XT, 3M ESPE) inserted into the crown interior, making close contact …

    brazil-ufrn Repository record for Desempenho clínico, discrepância marginal e interna de coroas monolíticas de zircônia ultratranslúcida, ensaio clínico controlado e randomizado: em até 2 anos (opens in a new tab)

  17. The effect of base stock and additive packages in an automotive oil on the friction and wear behaviour of overhead camshaft and finger follower systems

    … present in the oil. The use of the acetate replica technique proved a satisfactory method of analysing the change in surface topography of cam surfaces. Using the fully formulated oil the cam surface 'ran in' satisfactorily, by a process of plastic deformation and fracture, whilst the …

    brunel Repository record for The effect of base stock and additive packages in an automotive oil on the friction and wear behaviour of overhead camshaft and finger follower systems (opens in a new tab)

  18. Bioceramic Materials for Advanced Medical Applications

    Cílem disertační práce bylo připravit trojrozměrné biokeramické podpůrné systémy („skafoldy“), které by v budoucnu mohly pomoci při rekonstrukci a regeneraci poškozených kostních tkání. Porézní keramické pěny byly připraveny dvěma způsoby – replikační technikou a polymerizací in situ. Co se složení …

    brno-tech Repository record for Bioceramic Materials for Advanced Medical Applications (opens in a new tab)

  19. Keramické materiály používané v medicíně - výzvy a příležitosti

    Tato bakalářská práce se zabývá keramickými materiály používanými v medicíně, zejména v ortopedických a dentálních aplikacích. Úvodní část práce se zaměřuje na požadavky a současný stav biomateriálů používaných v kostním tkáňovém inženýrství, jejich výhody a nevýhody. V další podkapitole jsou …

    brno-tech Repository record for Keramické materiály používané v medicíně - výzvy a příležitosti (opens in a new tab)

  20. Surface Roughness In Manufacturing Processes Of Advanced High Strength Steels

    … tensile tests at different strains, and replication of the edge surfaces without unloading using a metallurgical replica technique, for post-measurement after the tests. The quality of the three edge preparation methods and the effect on edge cracking in tension are ranked. Tooling …

    wayne-thes Repository record for Surface Roughness In Manufacturing Processes Of Advanced High Strength Steels (opens in a new tab)