Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 30 for “"resettable"”

  1. Rare cell separation using resettable cell traps

    … reports a microfluidic device that employs novel resettable cell traps to separate cells based on size and deformability. The resettable cell trap is a microchannel with controllable cross-section, featuring recesses to temporarily store captured cells. Larger and less deformable cells flowing …

    ubc Repository record for Rare cell separation using resettable cell traps (opens in a new tab)

  2. PROGNOSTICS OF POLYMER POSITIVE TEMPERATURE COEFFICIENT RESETTABLE FUSES

    Polymer positive-temperature-coefficient (PPTC) resettable fuse has been used to circuit-protection designs in computers, automotive circuits, telecommunication devices, and medical devices. PPTC resettable fuse can trip from low resistance to high resistance under over-current conditions. The …

    maryland Repository record for PROGNOSTICS OF POLYMER POSITIVE TEMPERATURE COEFFICIENT RESETTABLE FUSES (opens in a new tab)

  3. Separation of circulating tumor cells using resettable cell traps

    … of cells. Our group previously reported the resettable cell trap (RCT) mechanism to perform micropore filtration in a way that is resistant to clogging. We improved the selectivity of this label-free mechanism by filtering the samples multiple times on chip and dramatically improving the …

    ubc Repository record for Separation of circulating tumor cells using resettable cell traps (opens in a new tab)

  4. Testing and Active Learning of Resettable Finite-State Machines

    This thesis proposes novel active-learning algorithms and testing methods for deterministic finite-state machines that (i) have a specified transition from every state on each input of the (fixed) alphabet and (ii) can be reliably reset to the initial state on request. These algorithms rely on the …

    whiterose Repository record for Testing and Active Learning of Resettable Finite-State Machines (opens in a new tab)

  5. Modeling and Validation of the Resettable Semi-Passive Stiffness Damper

    … control systems(i.e. passive, active, etc.). The Resettable Semi-Active Stiffness Damper (RSASD) hasbeen shown to be superior to other control systems at vibration suppression in thepresence of near-field earthquakes. It is made up of a cylinder, a double-acting piston,and a valve connecting both …

    ohiolink Repository record for Modeling and Validation of the Resettable Semi-Passive Stiffness Damper (opens in a new tab)

  6. New approaches to programmable matter : development of reusable and resettable programmable devices.

    Avec l’émergence de la technologie numérique, la matière conventionnelle limite le rythme du développement technologique, manquant d’intelligence et de polyvalence. Cela ouvre la possibilité de développer une matière programmable capable d’intégrer l’intelligence, le mouvement et la communication …

    star-france Repository record for New approaches to programmable matter : development of reusable and resettable programmable devices. (opens in a new tab)

  7. Resetting microstructures and properties in TRIP-assisted advanced high strength steels

    … to alloys that demonstrate this capability as resettable alloys. One resettable alloy is the transformation-induced plasticity-maraging (TRIP-maraging) steel. However, current resettable TRIP-maraging steels require long and unfeasible resetting treatments. The limit of resetting kinetics has …

    mit Repository record for Resetting microstructures and properties in TRIP-assisted advanced high strength steels (opens in a new tab)

  8. A epistemologia de David Hume: uma investigação acerca da legitimidade da crença

    … we will have criteria epistemically safe and resettable to identify, in this broad sphere of causal beliefs, which can be avoided and which should be followed. This dissertation will be structured from A Treatise of Human Nature and An Enquiry Concerning Human Understanding David Hume.

    brazil-ufpb Repository record for A epistemologia de David Hume: uma investigação acerca da legitimidade da crença (opens in a new tab)

  9. Photon statistics of light resonantly scattered from a three-level atom

    … of thermal atoms across this extended region a resettable coincidence counter was used;The photon statistics of light scattered from the three-level 5535 A transition in barium were investigated. These statistics agreed well with theory developed in conjunction with this work. An atomic …

    iastate Repository record for Photon statistics of light resonantly scattered from a three-level atom (opens in a new tab)

  10. Next-Generation Amplifiers for Beyond-5G Applications

    … amplifiers examined. Additionally, the use of resettable fuses for high-frequency circuit protection was discussed. These fuses were characterized by their power levels, input return loss, and response time. A set of specifications were developed as the minimum criteria for a fuse to protect a …

    hawaii Repository record for Next-Generation Amplifiers for Beyond-5G Applications (opens in a new tab)

  11. Static Analysis of a Concurrent Programming Language by Abstract Interpretation

    … states of an Erasmus programs. We also offer a Resettable Event order Vector for Erasmus processes to realistically implement our vector for large Erasmus programs using bounded space. We believe that our formal approach is also applicable to other types of process-oriented programs and MPI …

    concordia

  12. Correlator for a Basis-Space Architecture Ultra-Wideband Receiver

    … correlation operation in the new receivers is a resettable integrator function used to generate an inner product of the sampling basis and the received signal. This thesis develops a circuit architecture to accomplish the projection via a wideband integrator. The type of UWB signal for evaluation …

    ohiolink Repository record for Correlator for a Basis-Space Architecture Ultra-Wideband Receiver (opens in a new tab)

  13. Intrinsic conducting polymer current limiting device

    … limiting devices (CLDs), which are small self-resettable components used to protect circuitry in portable electronic appliances during situations of overcurrent. There are many existing solutions that enable the interruption and limitation of current surges in devices. A simple and common …

    hull Repository record for Intrinsic conducting polymer current limiting device (opens in a new tab)

  14. Resilient power and propulsion system design for eVTOL aircraft

    … compliance assessment for the use of non-resettable protection devices, specifically the Pyrofuse protection device, in eVTOL concept designs. The non-resettablenature of the device poses a challenge in the certification process for its integrationinto eVTOL electrical system protection. …

    strathclyde Repository record for Resilient power and propulsion system design for eVTOL aircraft (opens in a new tab)

  15. Connecting the Circadian Clock with Chemosensation

    … external environment, e.g., light-dark cycle. A resettable timekeeping mechanism called the circadian clock internally drives these cyclical changes with a ~24 hour period. Using electrophysiological, behavioral and molecular analyses, I tested where and how these two conserved processes, viz., …

    tamu Repository record for Connecting the Circadian Clock with Chemosensation (opens in a new tab)

  16. Analysis and design of classes of hybrid control systems

    … against state feedback and free running against resettable adaptive control for single input single output (SISO) systems. Simulations reveal that output feedback and free running adaptive schemes are incapable of producing stabilizing control in some cases of hybrid systems. Reset-table state …

    soton Repository record for Analysis and design of classes of hybrid control systems (opens in a new tab)

  17. IN-LINE MICROFLUIDIC PARTICLE PRECONCENTRATOR AND DETECTOR FOR CONTINUOUS FLOW MONITORING

    … acoustic sample preconcentration techniques for resettable particle enrichment, and an in-line somatic cell counter for mastitis monitoring.</p> <p>For the ACEK preconcentrator, ACEK is a new and promising technique to manipulate micro/bio-fluid and particles. There are many advantages over other …

    utk-theses Repository record for IN-LINE MICROFLUIDIC PARTICLE PRECONCENTRATOR AND DETECTOR FOR CONTINUOUS FLOW MONITORING (opens in a new tab)

  18. Os jogos pelo meio do caminho : a experiência dos simuladores de caminhada e a redefinição dos jogos digitais por seus aspectos de confronto e conflito

    … a confrontation and conflict, carried out in a resettable virtual environment. This work is affiliated with Frasca's methodological proposals, on the rhetoric of play, by Sicart, in the composition of the subject-player and Upton, in the situational design for games, to propose an analysis of …

    brazil-ufmg Repository record for Os jogos pelo meio do caminho : a experiência dos simuladores de caminhada e a redefinição dos jogos digitais por seus aspectos de confronto e conflito (opens in a new tab)

Page 1 of 2