Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 9 of 9 for “"residual ozone"”

  1. Ozone Disinfection in Bottled Water: A Model for the Bottled Water Industry

    Ozone is a powerful disinfectant that is widely used in the bottled water (BW) industry. Primary ozone disinfection occurs in a reaction tank with specific contact time, however, residual ozone in the water that is bottled may still possess disinfection activity. The purpose of this study was to …

    nebraska Repository record for Ozone Disinfection in Bottled Water: A Model for the Bottled Water Industry (opens in a new tab)

  2. Effect of Ozone and Ultraviolet Irradiation Treatments on Listeria monocytogenes Populations in Chill Brines

    The efficacy of ozone and ultraviolet light, used in combination, to inactivate Listeria monocytogenes in fresh (9% NaCl, 91.86% transmittance at 254 nm) and spent chill brines (20.5% NaCl, 0.01% transmittance at 254 nm) was determined. Preliminary studies were conducted to optimize parameters for …

    vt Repository record for Effect of Ozone and Ultraviolet Irradiation Treatments on Listeria monocytogenes Populations in Chill Brines (opens in a new tab)

  3. Μοντελοποίηση της λειτουργίας μιας εγκατάστασης επεξεργασίας νερού

    … variables of the WTP include: the dosages of residual ozone (O3), anionic polyelectrolyte (ANPE), polyaluminum chloride sulfate (PACl) and chlorine gas (Cl2(g)). Daily water sample analysis results and recordings from the WTP SCADA, covering a period of 38 months (1,188 values for each of the …

    greece Repository record for Μοντελοποίηση της λειτουργίας μιας εγκατάστασης επεξεργασίας νερού (opens in a new tab)

  4. An integrated computational fluid dynamics an kinetics study of ozonation in water treatment.

    … the level of turbulence intensity at the ozone contactor inlet. The model prediction of the overall tracer response corresponded closely to the experimental results. The framework of ozone reaction modelling was subsequently established using values of rate constants from the literature. …

    ukzn Repository record for An integrated computational fluid dynamics an kinetics study of ozonation in water treatment. (opens in a new tab)

  5. Catalytic ozonation of VOCS over different porous materials

    … gaseous pollutants from one phase to another. Ozone is a strong oxidization agent with catalytic properties that can eliminate VOCs completely with sufficient residence time. The use of ozonation with porous materials exploits the strong oxidizing capability of ozone with porous adsorbents that …

    hkust Repository record for Catalytic ozonation of VOCS over different porous materials (opens in a new tab)

  6. Application of microbubbles to ozonation for drinking water treatment.

    … as well as disinfect water. Conventional ozone contactors have a large energy requirement and deep tanks to ensure adequate mass transfer. As a result, the delivery of ozone into water is an energy intensive and expensive process. The use of microbubbles in water treatment is a new …

    cranfield Repository record for Application of microbubbles to ozonation for drinking water treatment. (opens in a new tab)

  7. Assessing the Effect of Pre-Oxidation at Different Stages of Water Treatment to Limit N-Nitrosodimethylamine (NDMA) Formation

    … in most cases. Hence, pre-oxidation with ozone, ozone/hydrogen peroxide (so-called advanced oxidation), or free chlorine was explored for precursor destruction to limit subsequent NDMA formation following addition of chloramines.In this study, batch experiments were performed to …

    umn Repository record for Assessing the Effect of Pre-Oxidation at Different Stages of Water Treatment to Limit N-Nitrosodimethylamine (NDMA) Formation (opens in a new tab)

  8. Επίδραση της τριτοβάθμιας επεξεργασίας στην τοξικότητα υγρών αποβλήτων αστικής προέλευσης

    … of secondary effluents included the effect of ozone dose (2.5, 5.0, 6.5, 7.3, 8.0 mg O3/L) and reaction time (2, 5, 15, 30 min). Secondary effluents were quite toxic to D. pulex with the immobilization of daphnids reaching 90%. On the contrary, negligible acute toxic effects were observed for …

    greece Repository record for Επίδραση της τριτοβάθμιας επεξεργασίας στην τοξικότητα υγρών αποβλήτων αστικής προέλευσης (opens in a new tab)

  9. The destruction of cyanobacterial toxins with oxidants used in drinking water treatment

    … and Milli-Q water. The waters were treated with ozone using the batch method and saxitoxin levels were measured in the samples using HPLC. The results for oxidation of saxitoxins in Milli-Q water versus HVTW show that despite the presence of natural organic matter(NOM) and the production of …

    adelaide Repository record for The destruction of cyanobacterial toxins with oxidants used in drinking water treatment (opens in a new tab)