Resistance thermometer characteristics and response time testing
… which enables the time constant of a platinum resistance temperature detector (PRTD) to be calculated in situ. Application of this method (called the loop current step response (LCSR) method) yielded errors in the time constant calculation of over 20 percent. Further analytical and numerical …
-
High performance analog linearization circuit for the Platinum Resistance Thermometer
<p>In the field of resistance thermometry there is a need for an analog circuit that provides an output voltage that is proportional to temperature. Although devices that perform this function have recently become available, their use is limited to applications in which temperatures vary slowly …
-
An apparatus to measure dropwise condensation heat transfer coefficients of steam
… utilized to control the heat flux. A thin film resistance thermometer was constructed to obtain the average surface temperature of the condensing surface. Inability to obtain linear and repeatable calibration data with this thermometer resulted in its being discarded. An intrinsic thermocouple …
-
Scanning thermal microscopy using nanofabricated probes
… and lift-off to form Au/Pd thermocouples and Pd resistance thermometer/heaters. Sensor dimensions down to 35 nm have been demonstrated. In the case of the sharp triangular tips, holes were etched into parts of the cantilever in order to provide self alignment of the sensor to the tip. On the …
-
The heat capacities of lithium-ammonia systems
… uork. Temperatures were measured with a platinum resistance thermometer [TRUNCATED]
-
Development of the Modified Hot Box: A Convective Heat Transfer Device for Measuring the Steady State and Transient Thermal Properties of Non-homogenous Building Materials
… to measure heat flow through eachspecimen, while resistance thermometer detectors monitored the temperature ofthe sample faces. Statistical methods, such as linear regression, were used tocalibrate the Modified Hot Box. Component data acquired by the Modified Hot Boxwill be used in future research …
-
Measurement of temperatures in unsteady gas flows
… of degrees from ambient. A thin platinum film resistance thermometer was developed, such that the temperature of the backing material could be varied independently of the temperature monitoring apparatus. From a knowledge of the temperature-time history of the platinum film, it was possible to …
-
Development of a Burnett-Isochoric apparatus for the study of the volumetric behavior of pure components and mixtures at high reduced temperature and high pressure, and development of a method for the analysis of PVT isochores
… Temperatures registered with a platinum resistance thermometer have accuracies that approach ±.1°C of the International Practical Temperature Scale of 1968. System design refinements have reduced the error contributions from elastic distortion and thermal expansion of the cells and from …
-
Thermodynamic properties of n-butanol
… calibrated against a standard platinum resistance thermometer to ± 0.05°C. Trial runs were made on purified water and pure (research grade) n-hexane. The results for water checked with Keyes'⁵⁵ data within 0.5 per cent, and for n-hexane checked with Kay's²³ vapor pressure equation within …
-
DEVELOPMENT OF A MICROSCALE ELECTROCHEMICAL PLATFORM FOR THE ANALYSIS OF THERMAL PROFILES OF IMMOBILIZED DNA SECONDARY STRUCTURES
… thin film that can function as both a platinum resistance thermometer (PRT) and as a resistive microheater. The device assembly as well as automation of the temperature control and electrochemical methods have been instituted to increase measurement repeatability with the microscale device. The …
-
The construction of an adiabatic calorimeter and its use in measuring specific heats
… shield and an evacuated outer case. A platinum resistance thermometer-heater was used to supply heat to the calorimeter vessel and to measure the vessel temperature. The heat input and the thermometer resistance were measured by using a potentiometer in conjunction with standard resistances. The …
-
Investigation of high wave number temperature and velocity spectra in air
… fluctuations were measured with a platinum resistance thermometer which consisted of a platinum wire 0.25 µm in diameter and about 0.30 mm in length. The velocity spectra results agree well with the classical results of Grant, Stewart and Moilliet (1962) and Pond, Stewart and Burling (1963). …
-
In-situ conductivity, temperature, and dissolved oxygen (CT-DO) sensor system for marine measurement
… open conductivity sensor, a Platinum Resistance Thermometer (PRT) bridge temperature sensor, and a DO sensor based on a platinum electrode inset into five 25 ?m deep wells. A 16-bit impedance measurement circuit was made to support the CT sensor. This has a typical battery life of one …
-
Turbulence spectra in the atmospheric boundary layer over the sea
… fluctuations were measured with a platinum resistance thermometer consisting of a platinum wire 2.5 microns in diameter and about 2mm long. The fluctuations of the quantities related to the dissipation rate were obtained from the velocity fluctuations using an analog computer to perform the …
-
Thermometry based on Whispering Gallery Mode resonators
… °C to 500 °C the most commonly used industrial thermometer is platinum resistance thermometer (PRT) with the uncertainties of 10 mK. The PRT offers high accuracy, low drift, a wide operating range; however, it is very sensitive to mechanical shock in handing and shipping. Besides, an AC …
-
Design, fabrication and characterisation of thermally optimised novel SThM probes
… The probe’s performance was characterised as a resistance thermometer (passive mode) and as a self-heated thermal conductance measurement device (active mode). Frequency domain measurements demonstrated that improved performance in both operating regimes was the result of changes to the …
-
Phonon scattering from monovalent substitutional impurities in sodium chloride
… in a liquid helium cryostat using germanium resistance thermometer~ which had Peen previously calibrated against a gas thermometer and a vapol;' pressure thermometer. The range 65°K to 300 0K was covered in a liquid nitrogen cryostat using platinum resistance thermometers prev.iously …
-
Quantitative impurities effects on temperatures of tin and aluminium fixed-point cells
… fixed points. It also uses long-stemplatinum resistance thermometers to interpolate between the fixed points from 660 °Cdown to 84 K (if one includes the Argon triple point). Impurities are a major source of uncertainty in the fixed point temperature (of the order of 1 mK). And a better …