Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"respiratory gating"”.

  1. Implementation of a video based respiratory gating system for radiation therapy

    … the dose to healthy lung tissue. In this work, a respiratory gated radiation therapy program is established at the Thompson Cancer Survival Center for the treatment lung cancer. A commercially available gating system is used to selectively deliver absorbed dose to moving target volumes during time …

    utk-theses Repository record for Implementation of a video based respiratory gating system for radiation therapy (opens in a new tab)

  2. Investigation of Respiratory Motion Management Techniques For Proton and Photon Radiotherapy of Lung Cancer

    … radiation such as high-energy photons. However, respiratory motion can significantly impact the delivered proton and photon dose distributions during lung cancer radiotherapy. The goals of this dissertation research were to evaluate the impact of respiratory motion and to estimate the benefit of …

    uthsc Repository record for Investigation of Respiratory Motion Management Techniques For Proton and Photon Radiotherapy of Lung Cancer (opens in a new tab)

  3. Verification of The Clinical Implementation of The Respiratory Gated Beam Delivery Technique With Synchrotron-Based Proton Irradiation

    … motion. One way to reduce uncertainty caused by respiratory motion is to use gated beam delivery. The main goal of this dissertation is to evaluate the respiratory gating technique in both passive scattering and scanning delivery mode. Our hypothesis for the study was that optimization of the …

    uthsc Repository record for Verification of The Clinical Implementation of The Respiratory Gated Beam Delivery Technique With Synchrotron-Based Proton Irradiation (opens in a new tab)

  4. Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging

    … thesis is to design, implement, and evaluate respiratory motion correction techniques that can overcome respiratory motion artifacts in PET/CT imaging. The thesis is composed of three main sections. The first section introduces a novel approach (free-breathing amplitude gating (FBAG) …

    rice Repository record for Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging (opens in a new tab)

  5. Respiratory motion correction in PET/CT imaging

    In dual modality PET-CT imaging, respiratory motion can introduce blurring in PET images and create a spatial mismatch between the PET and CT datasets. Attenuation correction errors can result from this mismatch, which can produce severe artefacts that potentially alter the clinical interpretation …

    kings Repository record for Respiratory motion correction in PET/CT imaging (opens in a new tab) Download PDF for Respiratory motion correction in PET/CT imaging (opens in a new tab)

  6. Optimization strategies for respiratory motion management in stereotactic body radiation therapy

    … The dose is applied in only a few fractions and respiratory organ and tumor motion is a source of uncertainty additional to interfractional set-up errors. Respiratory organ and tumor motion is highly patient-specific and it affects the whole radiotherapy treatment chain. In this thesis, motion …

    lmu-germany Repository record for Optimization strategies for respiratory motion management in stereotactic body radiation therapy (opens in a new tab)

  7. Spatio-Temporal Modeling Of Anatomic Motion For Radiation Therapy

    … while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, …

    vcu Repository record for Spatio-Temporal Modeling Of Anatomic Motion For Radiation Therapy (opens in a new tab)

  8. 4-D Modeling of Displacement Vector Fields for Improved Radiation Therapy

    … while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, …

    vcu Repository record for 4-D Modeling of Displacement Vector Fields for Improved Radiation Therapy (opens in a new tab)

  9. Clinical Benefit Analysis of Modified Motion Management Protocols

    … like abdominal compression, breath-hold, or respiratory gating are also outlined in this report. At Utah Valley Hospital, passive methods such as 4DCT and ITV contouring are standard, alongside compression. This project will explore whether Utah Valley Hospital’s current motion management …

    unlv Repository record for Clinical Benefit Analysis of Modified Motion Management Protocols (opens in a new tab) Download PDF for Clinical Benefit Analysis of Modified Motion Management Protocols (opens in a new tab)

  10. Comparison of sedated respiratory-gated computed tomography (CT) to anesthetized inspiratory : expiratory breath-hold CT in dogs

    [EMBARGOED UNTIL 08/01/2026] Dogs experiencing respiratory compromise typically have multiple respiratory disorders that can be underestimated or overlooked by thoracic radiography. The anesthetized, ventilator-assisted inspiratory: expiratory breath-hold (I:E BH) CT technique provides …

    missouri Repository record for Comparison of sedated respiratory-gated computed tomography (CT) to anesthetized inspiratory : expiratory breath-hold CT in dogs (opens in a new tab)

  11. Emission guided radiation therapy: a feasibility study

    … encompassment, breath-hold techniques, and respiratory gating have been proposed in the literature and implemented clinically. These methods have shown success in certain situations with different limitations. With the advent of image guided radiation therapy, real-time tumor tracking …

    gatech Repository record for Emission guided radiation therapy: a feasibility study (opens in a new tab)

  12. Movement correction by object recognition-based anatomical tracking in functional magnetic resonance urography (fMRU)

    … analysis. Images-time-series (no respiratory gating) of 100 kidneys were artificially generated (Matlab, TheMathworks, Natick, NA, USA). Respiratory movement was implemented by a sinusoidal coordinate shift with an amplitude of 3 cm and frequency of about 6 min-1. Renal intensity …

    cau-kiel Repository record for Movement correction by object recognition-based anatomical tracking in functional magnetic resonance urography (fMRU) (opens in a new tab)

  13. Image processing and machine learning applications in lung cancer treatment

    … CT to pathology but failed to include PET due to respiratory motion blurring. This was added to by including respiratory gating and the OncoFreeze algorithm in the workflow to reduce the effects of respiratory motion. A PET to pathology registration was evaluated using thresholding based …

    strathclyde Repository record for Image processing and machine learning applications in lung cancer treatment (opens in a new tab)

  14. Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy

    … for liver cancer treatments and investigate the gating parameters for acceptable plan delivery in terms of the dose to a moving volume and treatment delivery time. 10 patient plans for VMAT SABR liver were created using the Eclipse™ treatment planning system (TPS). The plans were then transferred …

    ubc Repository record for Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy (opens in a new tab) Download PDF for Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy (opens in a new tab)

  15. Application of Three-Dimensional Motion Tracking of Low-Activity Fiducial Positron-Emitting Markers in Radiation Therapy and Positron Emission Tomography

    … of this tracking technique, called PeTrack, for respiratory-gated radiotherapy and for motion-compensated PET imaging was evaluated.The feasibility of respiratory-gated radiotherapy using PeTrack was assessed. A respiratory gating interface was developed in LabVIEW to communicate with an Elekta …

    carleton Repository record for Application of Three-Dimensional Motion Tracking of Low-Activity Fiducial Positron-Emitting Markers in Radiation Therapy and Positron Emission Tomography (opens in a new tab)

  16. DEVELOPMENT AND APPLICATIONS OF FEATURE-GUIDED CARDIAC MOTION ESTIMATION METHODS FOR 4D CARDIAC PET

    … image quality. First, to reduce the influence of respiratory motion and improve the quality of cardiac PET images used in motion estimation, data-driven respiratory gating methods are proposed to allow accurate extraction of respiratory motion signal from the list-mode data. Time-of-flight PET …

    jhu Repository record for DEVELOPMENT AND APPLICATIONS OF FEATURE-GUIDED CARDIAC MOTION ESTIMATION METHODS FOR 4D CARDIAC PET (opens in a new tab)

  17. Dynamic respiratory tracking in the presence of cardiac motion for stereotactic arrhythmia radioablation (STAR)

    … radiation target is affected by both cardiac and respiratory motion, introducing errors in both treatment planning and delivery. Dynamic tracking is a motion management method which employs real-time radiation beam adjustment throughout treatment delivery, based on a respiratory correlation model …

    ubc Repository record for Dynamic respiratory tracking in the presence of cardiac motion for stereotactic arrhythmia radioablation (STAR) (opens in a new tab) Download PDF for Dynamic respiratory tracking in the presence of cardiac motion for stereotactic arrhythmia radioablation (STAR) (opens in a new tab)

  18. Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode

    Respiratory motion makes radiotherapy of abdominal targets, such as the liver difficult. Respiratory gating is used to treat tumours in select portions of the respiratory cycle where their location is well known, increasing target coverage precision and reducing normal tissue damage. The tradeoff …

    ubc Repository record for Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode (opens in a new tab) Download PDF for Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode (opens in a new tab)

  19. Automated review of patient position during DIBH breast hybrid IMRT using EPID images

    Deep Inspiration Breath Hold (DIBH) is a respiratory-gating technique employed in breast radiation therapy to lower the delivered radiation dose to the patient’s heart. When performing DIBH treatments, it is important to have a monitoring system to measure the quality of the patient's breath hold. …

    manitoba Repository record for Automated review of patient position during DIBH breast hybrid IMRT using EPID images (opens in a new tab)

  20. Application of Parallel Imaging to Murine Magnetic Resonance Imaging

    … to trigger the MRI scanner to the ECG and respiratory signals from the mouse in order to achieve images free from physiological motion artifacts is described. The imaging results from the compact 10-channel mouse array coils are presented, and the challenges associated with the work are …

    tamu Repository record for Application of Parallel Imaging to Murine Magnetic Resonance Imaging (opens in a new tab)

Page 1 of 2