Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 61 for “"retainers"”.

  1. Evaluation of fit for 3D printed retainers as compared to thermoform retainers

    ABSTRACT EVALUATION OF FIT FOR 3D PRINTED RETAINERS AS COMPARED TO THERMOFORM RETAINERS By David Cole, D.M.D. A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University Thesis Directors: Eser Tüfekçi, D.D.S., …

    vcu Repository record for Evaluation of fit for 3D printed retainers as compared to thermoform retainers (opens in a new tab)

  2. Patient preference and compliance between Hawley retainers and vacuum-formed retainers following orthodontic treatment.

    … in many orthodontic offices by vacuum-formed retainers (VFRs). There has yet to be a study that investigates preferences and reasons for noncompliance between Hawley and vacuum-formed retainers by allowing each to be worn within the same patient. Specific Aim: To determine differences in …

    louisville Repository record for Patient preference and compliance between Hawley retainers and vacuum-formed retainers following orthodontic treatment. (opens in a new tab)

  3. Creep, Hardness, and Elastic Modulus of Lingual Fixed Retainers Adhesives

    The aims of this study were twofold: a) to characterize a wide array of time-independent and -dependent properties and b) to find possible correlations among the properties tested. Seven commercially available orthodontic adhesives were included in this study and ten cylindrical specimens were …

    zurich Restricted access

  4. Influence of Mandibular Fixed Retainers on Diagnostic Quality of Cranial MRI

    … with different types of orthodontic lingual retainers in place. The study provides guidelines and recommendations for use of lingual retainer materials in those patients who are or may potentially undergo routine magnetic resonance imaging. Ten subjects had impressions taken and models made …

    loma-linda Repository record for Influence of Mandibular Fixed Retainers on Diagnostic Quality of Cranial MRI (opens in a new tab)

  5. Periodontal Health of Anterior Teeth with Two Types of Fixed Retainers

    Introduction: Fixed retainers for anterior teeth have become a popular method for maintaining the position and function of teeth after orthodontic treatment. Various retainer designs, wire sizes and types have been used over the years. One problem with fixed retainers is that they complicate oral …

    loma-linda Repository record for Periodontal Health of Anterior Teeth with Two Types of Fixed Retainers (opens in a new tab)

  6. In vivo and in vitro color evaluation of clear thermoplastic retainers

    … post-treatment changes. Although removable retainers are preferable when compared with fixed retainers regarding oral hygiene, they require patient compliance and prolonged use. In order to increase patient acceptance of removable devices, clear thermoplastic retainers have been introduced …

    greece Repository record for In vivo and in vitro color evaluation of clear thermoplastic retainers (opens in a new tab)

  7. A comparison of high school dropouts and retainers on career choice competencies

    … maturity) of white male high school dropouts and retainers in the 10th and 11th grades in Cabell County, West Virginia. Dropouts and retainers were compared on the following career choice competencies as measured by the Career Maturity Inventory (CMI): (1) self appraisal, (2) occupational …

    vt Repository record for A comparison of high school dropouts and retainers on career choice competencies (opens in a new tab)

  8. Using photo-elicitation to explore young people’s short-term experience of orthodontic retainers

    … their immediate experience and expectation of retainers, the process of adaptation and motivating factors. Challenges to adherence were mostly ascribed to day-time wear, despite normalisation of retainers in young people’s lives. Interventions to help individuals overcome the initial adaptation …

    whiterose Download PDF for Using photo-elicitation to explore young people’s short-term experience of orthodontic retainers (opens in a new tab)

  9. Wear and Fatigue Resistance: An In-Vitro Comparison of Three Materials for Vacuum-Formed Retainers

    … materials for the fabrication of vacuum-formed retainers in a simulated oral environment. Methods: Three materials were tested: Essix ACE, Taglus, and Zendura. To test wear resistance, 21 maxillary retainers of each material (63 overall) were mounted on zirconia models into an Artificial …

    umn Repository record for Wear and Fatigue Resistance: An In-Vitro Comparison of Three Materials for Vacuum-Formed Retainers (opens in a new tab)

  10. The Effect of Print Angulation on the Accuracy and Precision of 3D-Printed Orthodontic Retainers

    … and precision of 3- dimensional (3D) printed retainers at various angulations, 2) to evaluate the effect of angulation on printing time and the amount of resin consumed. Methods: Using a stereolithography (SLA) 3D printer, a total of 60 clear retainers were printed at five angulations (n=12, …

    vcu Repository record for The Effect of Print Angulation on the Accuracy and Precision of 3D-Printed Orthodontic Retainers (opens in a new tab)

  11. Impact of Facial Divergence on Post-Treatment Settling in Patients Retained With Clear-Overlay Retainers

    … were retained with upper and lower clear overlay retainers and a lower bonded retainer. Initial lateral cephalograms were used to categorize patients as hyperdivergent or hypodivergent. Intraoral scans from debond and first retention check appointments were compared. Changes in areas of contact …

    tamu Repository record for Impact of Facial Divergence on Post-Treatment Settling in Patients Retained With Clear-Overlay Retainers (opens in a new tab)

  12. Quantification of artifacts caused by fixed retainers in dental-dedicated MRI – a descriptive In vitro study

    … produced by a variety of common fixed lingual retainers when scanned in a dental-dedicated MRI (ddMRI) – a low field strength (0.55T) MRI scanner using a dental dedicated extraoral coil. Materials and Methods: Six common orthodontic fixed retainers were scanned in vitro using a 0.55T MRI …

    umn Repository record for Quantification of artifacts caused by fixed retainers in dental-dedicated MRI – a descriptive In vitro study (opens in a new tab)

  13. A Comparison of Three-Dimensional Printing Technologies on the Precision, Trueness, and Accuracy of Printed Retainers

    … and accuracy of 3D printed orthodontic clear retainers produced using printer systems with various printing technologies. Methods: Retainers (n=15) were printed using four different 3D printers: a stereolithography (SLA) printer, two different digital light processing (DLP and cDLP) printers, …

    vcu Repository record for A Comparison of Three-Dimensional Printing Technologies on the Precision, Trueness, and Accuracy of Printed Retainers (opens in a new tab)

  14. Efficacy of Different Retention Types Post-Orthodontic Treatment

    … to evaluate the efficacy of 3 different types of retainers (Hawley removable, Essix removable and Fixed) of the mandibular and maxillary anterior sextant and to assess patient perception of crowding. Materials and Methods: A retrospective clinical evaluation of 80 patients treated at the …

    uconn-diss Repository record for Efficacy of Different Retention Types Post-Orthodontic Treatment (opens in a new tab)

  15. The outcome and stability of anterior open bite treatment with clear aligners in adults

    … with upper and lower fixed and vacuum-formed retainers. Eleven cephalometric measurements at pretreatment (T1), end-of-active-treatment (T2), and at least 1-year post-treatment (T3) were evaluated. The changes during the treatment and retention period were calculated. Results: Mean …

    u-pacific Repository record for The outcome and stability of anterior open bite treatment with clear aligners in adults (opens in a new tab)

  16. Objective evaluation of compliance after orthodontic treatment using Hawley or Vacuum- formed retainers. A two- center randomized controlled trial over a three- month period

    Η συγκράτηση του θεραπευτικού αποτελέσματος είναι ζωτικής σημασίας και αποτελεί αναπόσπαστο μέρος της ορθοδοντικής θεραπείας. Ανεξαρτήτως του πρωτοκόλλου συγκράτησης που χρησιμοποιείται, η συνεργασία του ασθενούς είναι καθοριστικής σημασίας για τη μακροπρόθεσμη επιτυχία της ορθοδοντικής θεραπείας. …

    athens Repository record for Objective evaluation of compliance after orthodontic treatment using Hawley or Vacuum- formed retainers. A two- center randomized controlled trial over a three- month period (opens in a new tab)

  17. Evaluating Changes in the Inter-Occlusal Space During Orthodontic Retention Stage

    … occlusal coverage and no occlusal coverage retainers, age, and gender were compared at all time points. Results: 90 patients were enrolled in the study. The Total Surface Area within Range increased in the first month. The surface area of teeth in the -0.6mm to 0.25mm category stayed …

    washington Repository record for Evaluating Changes in the Inter-Occlusal Space During Orthodontic Retention Stage (opens in a new tab)

  18. Efficacy of Temporary Fixed Retention Following Comprehensive Orthodontic Treatment

    … temporary fixed mandibular retention plus Hawley retainers compared to (B) a similar group retained with just removable retention (standard Hawley type retainers alone). Fixed retainers were removed after having been in place for about 2.5 years. Following this period, use of removable retention …

    tenn-hsc Repository record for Efficacy of Temporary Fixed Retention Following Comprehensive Orthodontic Treatment (opens in a new tab)

  19. The effect of cleaning and tooth whitening agents on the mechanical properties of two thermoplastic orthodontic retainer materials

    Thermoplastic retainers are removable appliances used to prevent teeth from moving from their corrected position after orthodontic treatment. Polyethylene and polypropylene and copolymers of these are used to fabricate thermoplastic retainers. The aim of this study was to investigate the effect of …

    birmingham Download PDF for The effect of cleaning and tooth whitening agents on the mechanical properties of two thermoplastic orthodontic retainer materials (opens in a new tab)

Page 1 of 4