Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"retroreflective markers"”.

  1. The Use of Real-Time Feedback to Improve Kinematic Marker Placement Consistency Among Novice Examiners

    … kinematic data. Twelve novice examiners placed retroreflective markers on a single runner. For each examiner, a running trial was analyzed using two static trials: (1) PRE and (2) POST implementation of the feedback tool. The protocol was repeated a second time, one week later, resulting in …

    calgary Repository record for The Use of Real-Time Feedback to Improve Kinematic Marker Placement Consistency Among Novice Examiners (opens in a new tab)

  2. Search Methods for Mobile Manipulator Performance Measurement

    … is evaluated through its ability to intercept retroreflective markers using a photoelectric sensor attached to the end-effector. Compared to the deterministic search approach, we observed improved interception capability with comparable search times, thereby enabling the effective performance …

    marquette Repository record for Search Methods for Mobile Manipulator Performance Measurement (opens in a new tab)

  3. Ankle-Knee Initial Contact Angle and Latency Period to Maximum Angle are Affected by Prolonged Run

    … habitual, and minimalist. Sixteen anatomical retroreflective markers, as well as seven tracking clusters, were placed on the participants’ lower extremities. The participants ran at a self-selected pace for 31 minutes. Kinematic data collected every five minutes beginning at minute one. Angle …

    gsu Repository record for Ankle-Knee Initial Contact Angle and Latency Period to Maximum Angle are Affected by Prolonged Run (opens in a new tab)

  4. Biomechanical Comparison of "Old" and "New" Cheer Shoes in Collegiate Cheerleaders

    … ± 9.33 kg; 162.70 ± 6.68 cm). Sixteen anatomical retroreflective markers were placed on each participants’ lower extremities. Participants completed randomized trials of ten balance conditions as well as step-down tasks consisting of a leveled and a tilted platform. Data collected from two days of …

    gsu Repository record for Biomechanical Comparison of "Old" and "New" Cheer Shoes in Collegiate Cheerleaders (opens in a new tab)

  5. The Effect of Patellofemoral Pain on Joint Motion and Variability During a Prolonged Run

    … ± 6.9 kg; 1.67 ± 0.11 m). Sixteen anatomical retroreflective markers, as well as 4 tracking clusters, were placed on the participants’ lower extremities. The participants ran at a self-selected pace on an instrumented treadmill. Data collected from the beginning, middle, and end of the run was …

    gsu Repository record for The Effect of Patellofemoral Pain on Joint Motion and Variability During a Prolonged Run (opens in a new tab)

  6. The Development and Validation of a Biomechanical Model to Describe Golf Swings: A Focus on Rotational Mechanics and Performance

    … to describe the golf swing. The model used 47 retroreflective markers to capture swing data with a 12-camera Vicon MX motion capture system. Motion data was collected at 250Hz, the data was processed, and a 17 segment custom biomechanical model was constructed in Visual3D (c-motion, Derwood, …

    uconn-diss Repository record for The Development and Validation of a Biomechanical Model to Describe Golf Swings: A Focus on Rotational Mechanics and Performance (opens in a new tab)

  7. Measurement of Cervical Vertebrae Strain for Assessment of Injury Mechanisms

    … anteriorly and articulating process posteriorly. Retroreflective markers were placed on the upper PMMA plate to measure motion in a three cervical spine unit. A knife edge device was used to model flexion and extension movements in the spine. A uniform device was made to observe the spine under …

    marquette Repository record for Measurement of Cervical Vertebrae Strain for Assessment of Injury Mechanisms (opens in a new tab)

  8. Development of a Robotic Positioning and Tracking System for a Research Laboratory

    … system is designed to measure the positions of retroreflective markers attached to any object that is being monitored. A fully automated camera calibration procedure is developed with an emphasis on accuracy. The potential accuracy of this system is demonstrated and problems that limit accuracy …

    the-open-u Download PDF for Development of a Robotic Positioning and Tracking System for a Research Laboratory (opens in a new tab)

  9. A System for Foot Joint Kinetics – Integrating Plantar Pressure/Shear with Multisegment Foot Modeling

    … (1.0, 1.3, and 1.6 m/s, respectively) wearing retroreflective markers according to an MSF model. Plantar shear forces and ankle, midtarsal, and first metatarsophalangeal (MTP) joint kinetics were reported. Speed effects on joint net work were evaluated with a repeated measures ANOVA. Results: …

    byu Repository record for A System for Foot Joint Kinetics – Integrating Plantar Pressure/Shear with Multisegment Foot Modeling (opens in a new tab) Download PDF for A System for Foot Joint Kinetics – Integrating Plantar Pressure/Shear with Multisegment Foot Modeling (opens in a new tab)

  10. Effect of of water level on kinematics of healthy horses walked on an aquatic treadmill compared to conventional rehabilitation techniques

    … land treadmill (LT), Zinc oxide (for UWTM) or retroreflective markers (for conventional surfaces) were used as skin markers and placed at four specific anatomical locations on the left fore and hind limbs. Five gait cycles of each horse for each surface were analyzed. Maximal flexion/extension …

    umn Repository record for Effect of of water level on kinematics of healthy horses walked on an aquatic treadmill compared to conventional rehabilitation techniques (opens in a new tab)

  11. Triangular Cosserat Point Element Method for Reducing Soft Tissue Artifact: Validation and Application to Gait

    … This is most readily accomplished by applying retroreflective markers to a participant’s skin and tracking the position of the markers during motion. Skin and adipose tissue move independently of the underlying bone during motion creating error known as soft tissue artifact (STA), the primary …

    calpoly Repository record for Triangular Cosserat Point Element Method for Reducing Soft Tissue Artifact: Validation and Application to Gait (opens in a new tab)

  12. DEVELOPMENT, VALIDATION, AND APPLICATION OF A NONINVASIVE SPINAL MOTION MEASUREMENT SYSTEM

    … (T7,T12,L3,L5) as measured by adhesive skin markers versus motion measured by bone pins implanted into the vertebrae. Cadaver torsos were tested in lateral‐bending, flexion and axialrotation. Mean differences in vertebral body angular motion between skin markers and bone pin markers were …

    uky-thes Repository record for DEVELOPMENT, VALIDATION, AND APPLICATION OF A NONINVASIVE SPINAL MOTION MEASUREMENT SYSTEM (opens in a new tab)

  13. Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties

    … Prior to running each day, participants had 32 retroreflective markers placed upon them for motion analysis collection. Additionally, participants had their Achilles tendon imaged via ultrasound pre and post run. On a separate day 24 of the participants underwent an ultrashort echo time (UTE) …

    byu Repository record for Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties (opens in a new tab) Download PDF for Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties (opens in a new tab)

  14. Instrumented gait analysis post-anterior cruciate ligament reconstruction in pediatric patients: A non-invasive method for quantifying the static and dynamic leg axis

    … (mean age: 12 ± 3) at 12 months post‐injury. Retroreflective markers were placed using the CAST lower body model. The gait was recorded in 3D using 12 infrared and two video cameras. Ground reaction forces were measured with force plates. Frontal knee alignment was assessed from kinematic data …

    qucosa-diss

  15. The effects of mid-air adjustments on knee joint loading when landing from a jump

    … of 21 randomly selected trials. A total of 23 retroreflective markers on the right and left lower extremities were used to determine the 3D orientation of the segments (Peak Motus). Inverse dynamics were used to calculate joint moments and reaction forces at the knee joint. Kinematics were …

    iastate Repository record for The effects of mid-air adjustments on knee joint loading when landing from a jump (opens in a new tab)

  16. Biomechanical changes to the trunk and lower extremities due to variations of the forward lunge exercise

    … leg during the lunges. A total of thirty three retroreflective markers were placed on the subject and the dumbbells used for the external load. All lunges were done on two portable force platforms while an 8 camera motion capture system recorded the movement. A multivariate ANOVA was used to …

    iastate Repository record for Biomechanical changes to the trunk and lower extremities due to variations of the forward lunge exercise (opens in a new tab)

  17. Robotic Soft Esophagus Design, Modeling, and Control for Endoprosthetic Stent Testing and Food Swallow Investigation

    … and motion capture experiments by placing retroreflective markers were performed on it. The x, y, and z-axis movement of the markers were recorded in datasets. A data-driven model, explicitly defining the underlying Differential Equations (DEs) of RoSE dynamics, was identified by applying …

    auckland-ms Repository record for Robotic Soft Esophagus Design, Modeling, and Control for Endoprosthetic Stent Testing and Food Swallow Investigation (opens in a new tab)

  18. Sledování pohybu autíček na autodráze

    Táto diplomová práca sa zaoberá návrhom, realizáciou a experimentálnym overením kamerového systému na sledovanie pohybu autíčok na autodráhe. Navrhnutý systém využíva kameru s globálnou uzávierkou, infračervené osvetlenie a retroreflexné markery na určenie polohy a orientácie autíčka na trati. …

    brno-tech Repository record for Sledování pohybu autíček na autodráze (opens in a new tab)

  19. REFRAME: fundamentals of a reference frame alignment method towards kinematic phenotyping of total knee arthroplasty patients based on mobile gait analysis

    … by optoelectronic systems, often employing retroreflective markers. Frequently considered the “gold standard” despite known susceptibility to errors associated with soft tissue artefact, optical marker systems are not only difficult to use and time-consuming, but also cumbersome and …

    lmu-germany Repository record for REFRAME: fundamentals of a reference frame alignment method towards kinematic phenotyping of total knee arthroplasty patients based on mobile gait analysis (opens in a new tab)

  20. Use of Biomechanical Motion Analysis and Pelvic Surgery Simulator for the Prevention of Surgical Errors in Mid-urethral Sling Anti-Incontinence Surgery

    … instrument and surgeon body were equipped with retroreflective markers to facilitate the motion tracking during this procedure, using OptiTrack Flex 13 motion capture system. Multibody kinematic models were developed in MSC ADAMS to analyze the surgical instrument kinematics. Musculoskeletal …

    umkc Repository record for Use of Biomechanical Motion Analysis and Pelvic Surgery Simulator for the Prevention of Surgical Errors in Mid-urethral Sling Anti-Incontinence Surgery (opens in a new tab)