  1. Performance evaluation of a solar heating plant in Ellös municipality

    … was analysed for correct system operation. The return network temperature to the plant was noted to be too high. This high temperature limited the solar collectors contribution to the storage tank to operating temperatures above 60.6°C. Further data analysis, indicated that the distribution …

    chalmers Repository record for Performance evaluation of a solar heating plant in Ellös municipality (opens in a new tab)

  2. Spot the difference! : On the way towards automated fault handling in district heating buildings

    … customer installations as a tool to reduce their return temperature levels. Reduced return temperatures would make it possible to improve the efficiency of the district heating systems and decrease their environmental impact. Faults in the customer installations cause high return temperatures that …

    lund Repository record for Spot the difference! : On the way towards automated fault handling in district heating buildings (opens in a new tab)

  3. Investigation of system effects of return flow temperature in a district heating system containing waste heat sources

    … a concept to recycle the available low temperature heat in the return flow of the DH in order to use it in an industrial heat pump to lift the temperature in the supply flow of the DH. The effect of the heat pump on achieving a maximum temperature reduction of the DH return flow was …

    chalmers Repository record for Investigation of system effects of return flow temperature in a district heating system containing waste heat sources (opens in a new tab)

  4. Fourth Generation District Heating, the prospects of Gothenburg: An investigation of the 4GDH concept and the motivations to implement it in Gothenburg

    … has been identified by higher supply and return temperatures, compared to the suggested temperature levels of the fourth generation of (50/20) ◦C. One aim with 4GDH is to secure the role of DH in a future sustainable energy system. Cost and resource efficient heat production and distribution …

    chalmers Repository record for Fourth Generation District Heating, the prospects of Gothenburg: An investigation of the 4GDH concept and the motivations to implement it in Gothenburg (opens in a new tab)

  5. Modelling of district heating grid

    … the following parameters: the customer supply temperature and the grid volume flowrate are calculated to illustrate how the generation units are operated to meet the customers’ heating demand. Furthermore, heat loss is estimated as it’s an essential parameter to the feasibility of district …

    chalmers Repository record for Modelling of district heating grid (opens in a new tab)

  6. Fault handling processes in district heating customer installations : Current and future solutions

    … heating systems, problems occur due tothe high temperature levels in the systems. There are many reasons to why the temperaturelevels are high, but one frequently occurring issue is that the return temperatures of thecustomer installations are undesirably high due to faults in the substations or …

    lund Repository record for Fault handling processes in district heating customer installations : Current and future solutions (opens in a new tab)

  7. Innovative heat exchangers for solar water heaters

    … modulate the flow rate such that the collector return temperature is always higher than the temperature in the top of the tank.

    unsw Repository record for Innovative heat exchangers for solar water heaters (opens in a new tab)

  8. Methodology for Determining the Optimal Operating Strategies for a Chilled Water Storage System

    … model is adopted to simulate the loop supply and return temperature difference as well as the loop total flow rate demand. In the control strategy sub-model, except for three conventional control strategies and the operation without TES, a new control strategy is advanced to load the chiller …

    tamu Repository record for Methodology for Determining the Optimal Operating Strategies for a Chilled Water Storage System (opens in a new tab)

  9. Transition towards carbon neutral district heating by utilising low-temperature heat

    … was investigated. Especially, the role of low-temperature waste heat from the data centres in Espoo during the transition and feasibility of electrified district heating during electricity price shocks were studied. Utilising heat from district heating network's return water to provide heating …

    aalto Repository record for Transition towards carbon neutral district heating by utilising low-temperature heat (opens in a new tab)

  10. To analyse measurements is to know!

    … this is compensated for by increased supply temperature. In future district heating systems with essential lower distribution temperatures, this will not be an available option. Continuous commissioning of substations will be necessary to detect faults quickly.

    lund Repository record for To analyse measurements is to know! (opens in a new tab)

  11. AI-Based Methods for Reliable Building Performance Management

    … The controller maintained acceptable indoor temperatures and reduced the mean district heating return temperature by 3.85 °C. The KNN surrogate model achieved a root-mean-square error (RMSE) of 9.12 kW and a coefficient of determination (R²) of 0.9184. Offline evaluation using the surrogate …

    lund Repository record for AI-Based Methods for Reliable Building Performance Management (opens in a new tab)

  12. Zur Bewertung der Energieeffizienz von Fernwärmesystemen unter Berücksichtigung des Fernwärmetemperaturniveaus

    Bei der Auslegung und Überprüfung der Betriebsweise von Fernwärmesystemen (FWS) ist eine Analyse der gesamten Prozesskette eines FWS – Erzeugung, Verteilung und Übergabe – notwendig, um eine bestmögliche Gestaltung derselben zu erreichen. Einen Ansatz zur Optimierung der Betriebsweise bietet die …