Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 10 of 10 for “"ribbed strip"”.
-
Pullout Strength of Welded Wire and Ribbed Strip Reinforcement in Lightweight Cellular Concrete Backfill Behind Mechanically Stabilized Earth Wall
… performing pullout tests on welded wire and ribbed strip reinforcements in MSE walls to determine the pullout friction coefficient (F*), reinforcement pullout behavior, and LCC properties. A large-scale test box (10 feet wide x 12 feet long x 10 feet high) supported by a steel resisting …
-
Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements
… square piles. The H-piles were tested with ribbed strip soil reinforcement at a wall height of 15 feet, and the square piles were tested with welded wire reinforcement at a wall height of 20 feet. The H-piles were spaced from the back face of the MSE wall at pile diameters 4.5, 3.2, 2.5, and …
-
Large-Scale Testing of Reinforced Lightweight Cellular Concrete Backfill for MSE Walls
… four lifts of Class II LCC 2.5 feet thick with ribbed-strip reinforcements at the center of each lift. After the LCC was cured, two static load tests were performed by applying surcharge to the surface of the LCC using six hydraulic jacks. The static load tests compared the LCC behavior of an …
-
Study of the soil-reinforcement friction coefficient
… has been reviewed. Actual site material, strip and soil has been employed in this investigation. Shear tests on soil samples compacted at various densities using both direct shear and triaxial tests were carried out in order to develop a relationship between dry density and angle of …
-
Design for Pullout Resistance and Global Stability of Metallic Reinforcements in MSE Walls with Lightweight Cellular Concrete Backfill
… new test data on the pullout resistance of ribbed-strip and welded-wire mesh reinforcements at high pressures. The pullout tests at high pressures were conducted in which four test prisms (2 ft wide x 10 ft long x 2' tall) that were filled with LCC with welded-wire mesh reinforcement on one …
-
Lateral Resistance of 24-inch Statically Loaded and 12.75-Inch Cyclically Loaded Pipe Piles Near a 20-ft Mechanically Stabilized Earth (MSE) Wall
… 5’x10’ concrete panels and was supported with ribbed strip and welded wire streel reinforcements. The computer software LPILE was used to back-calculate P-multipliers for the 24” piles. P-multipliers are used to indicate the amount of reduction in lateral resistance the piles experience due to …
-
LCC MSE Walls
… box was filled with four lifts of LCC with steel ribbed-strip reinforcements extending into the LCC behind the MSE wall panels at the center of each lift. After the LCC was cured, two static load tests were performed by applying a surcharge load to the surface of the LCC. In one test, surcharge …
-
Prediction Equations to Determine Induced Force on Reinforcing Elements Due to Laterally Loaded Piles Behind MSE Wall and Lateral Load Test on Dense Sand
… prediction equation (Eq. 3-4) was developed for ribbed-strip reinforcements that included the effect of pile diameter and larger head loads. With 1058 data points, this equation has an R2 value of 0.72. A general prediction equation (Eq. 3-9) was also developed for welded-wire reinforcements that …
-
Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements
… wall was constructed using welded-wire grid and ribbed strip inextensible reinforcements. This paper focuses on four lateral load tests conducted on steel pipe piles located behind a 20-ft section of MSE wall reinforced with welded-wire grids. Results showed that measured lateral resistance …
-
Pullout Resistance of MSE Wall Steel Strip Reinforcement in Uniform Aggregate
… mechanically stabilized earth (MSE) walls. Steel strips are one type of reinforcement used to stabilize aggregate backfill through anchorage. In the current MSE wall design, pullout capacity of steel strips is evaluated to ensure internal stability of the reinforced mass. The pullout resistance of …