Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"ribbed strip"”.

  1. Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements

    … square piles. The H-piles were tested with ribbed strip soil reinforcement at a wall height of 15 feet, and the square piles were tested with welded wire reinforcement at a wall height of 20 feet. The H-piles were spaced from the back face of the MSE wall at pile diameters 4.5, 3.2, 2.5, and …

    byu Repository record for Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements (opens in a new tab) Download PDF for Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements (opens in a new tab)

  2. Large-Scale Testing of Reinforced Lightweight Cellular Concrete Backfill for MSE Walls

    … four lifts of Class II LCC 2.5 feet thick with ribbed-strip reinforcements at the center of each lift. After the LCC was cured, two static load tests were performed by applying surcharge to the surface of the LCC using six hydraulic jacks. The static load tests compared the LCC behavior of an …

    byu Repository record for Large-Scale Testing of Reinforced Lightweight Cellular Concrete Backfill for MSE Walls (opens in a new tab) Download PDF for Large-Scale Testing of Reinforced Lightweight Cellular Concrete Backfill for MSE Walls (opens in a new tab)

  3. Study of the soil-reinforcement friction coefficient

    … has been reviewed. Actual site material, strip and soil has been employed in this investigation. Shear tests on soil samples compacted at various densities using both direct shear and triaxial tests were carried out in order to develop a relationship between dry density and angle of …

    glasgow Download PDF for Study of the soil-reinforcement friction coefficient (opens in a new tab)

  4. Design for Pullout Resistance and Global Stability of Metallic Reinforcements in MSE Walls with Lightweight Cellular Concrete Backfill

    … new test data on the pullout resistance of ribbed-strip and welded-wire mesh reinforcements at high pressures. The pullout tests at high pressures were conducted in which four test prisms (2 ft wide x 10 ft long x 2' tall) that were filled with LCC with welded-wire mesh reinforcement on one …

    byu Repository record for Design for Pullout Resistance and Global Stability of Metallic Reinforcements in MSE Walls with Lightweight Cellular Concrete Backfill (opens in a new tab) Download PDF for Design for Pullout Resistance and Global Stability of Metallic Reinforcements in MSE Walls with Lightweight Cellular Concrete Backfill (opens in a new tab)

  5. LCC MSE Walls

    … box was filled with four lifts of LCC with steel ribbed-strip reinforcements extending into the LCC behind the MSE wall panels at the center of each lift. After the LCC was cured, two static load tests were performed by applying a surcharge load to the surface of the LCC. In one test, surcharge …

    byu Repository record for LCC MSE Walls (opens in a new tab) Download PDF for LCC MSE Walls (opens in a new tab)

  6. Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements

    … wall was constructed using welded-wire grid and ribbed strip inextensible reinforcements. This paper focuses on four lateral load tests conducted on steel pipe piles located behind a 20-ft section of MSE wall reinforced with welded-wire grids. Results showed that measured lateral resistance …

    byu Repository record for Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements (opens in a new tab) Download PDF for Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements (opens in a new tab)

  7. Pullout Resistance of MSE Wall Steel Strip Reinforcement in Uniform Aggregate

    … mechanically stabilized earth (MSE) walls. Steel strips are one type of reinforcement used to stabilize aggregate backfill through anchorage. In the current MSE wall design, pullout capacity of steel strips is evaluated to ensure internal stability of the reinforced mass. The pullout resistance of …

    ku Repository record for Pullout Resistance of MSE Wall Steel Strip Reinforcement in Uniform Aggregate (opens in a new tab)