Results 1 to 20 of 22 for “"ring array"”

  1. Broadband beamforming and direction finding using concentric ring array

    Sensor arrays have been used widely in applications including radar, sonar, seismology, biomedicine, communications and imaging. A very popular type of sensor array is circular array, which has almost invariant array pattern in azimuthal plane. This dissertation considers beamformer design and …

    missouri Repository record for Broadband beamforming and direction finding using concentric ring array (opens in a new tab)

  2. Ring-array photoacoustic tomography for imaging human finger vasculature

    付記する学位プログラム名: 充実した健康長寿社会を築く総合医療開発リーダー育成プログラム

    kyoto Repository record for Ring-array photoacoustic tomography for imaging human finger vasculature (opens in a new tab)

  3. Adaptive array signal processing using the concentric ring array and the spherical array

    … partial adaptive beamforming using concentric ring and spherical arrays for acoustic signals on a partially known interference environment. We propose novel methods to choose intra-ring weights that take advantage of the prior knowledge about the characteristics of some of the interferences …

    missouri Repository record for Adaptive array signal processing using the concentric ring array and the spherical array (opens in a new tab)

  4. Signal processing techniques for array synthesis, beamforming, direction finding and calibration

    … original work on the following five areas of array processing: i) array weight synthesis, ii) array geometry synthesis, iii) broadband adaptive array beamforming, iv) broadband direction finding and v) array calibration. In the area of array weight synthesis, a general and flexible method is …

    nanyang Repository record for Signal processing techniques for array synthesis, beamforming, direction finding and calibration (opens in a new tab)

  5. Methodologies for the use of electrical and electromagnetic methods in complex, subterranean environments

    … identify and monitor dangerous water-bearing regions. Mines are often noisy environments for data collection because of infrastructure. Since conventional data quality control methodologies are poorly adapted for large 3D, tunnel-based datasets I developed a new methodology. To reduce …

    ubc Repository record for Methodologies for the use of electrical and electromagnetic methods in complex, subterranean environments (opens in a new tab)

  6. Particle sizing in a solid propellant rocket motor using a light scattering technique

    … Particle size was determined using light scattering techniques . The present optical components limit the lower measurable particle size to approximately three microns. During the investigation, spurious light was detected in the motor optical path. It was determined that transient pressure …

    nps Repository record for Particle sizing in a solid propellant rocket motor using a light scattering technique (opens in a new tab)

  7. Novel acoustic arrays and array pattern synthesis methods

    … this thesis is to propose several novel acoustic arrays which are capable of generating desired search-light-type and fan-type beams with greatly reduced sidelobes. These novel acoustic arrays have fewer elements than conventional arrays of similar performance. The design of such novel arrays is …

    uvic Repository record for Novel acoustic arrays and array pattern synthesis methods (opens in a new tab)

  8. A high-flux solar concentrating system.

    … has been developed and is capable of delivering high energy fluxes to a remote target. Salient performance results include flux concentrations approaching 1000 suns with an overall optical efficiency of 13%, measured from the inlet of the collector to the fibre outlet. The system comprises a …

    ukzn Repository record for A high-flux solar concentrating system. (opens in a new tab)

  9. On the Development of Full-view Photoacoustic Computed Tomography System for Biomedical Applications

    … the development of full-view PACT system with ring-array transducer that overcomes these challenges. Its full detection angle along the imaging plane eliminates limited-view artifact for wide-field high-resolution PACT. Exploring the lower band of the frequency spectrum, from the wide bandwidth …

    duke Repository record for On the Development of Full-view Photoacoustic Computed Tomography System for Biomedical Applications (opens in a new tab)

  10. USE OF AN ELECTRICAL IMPEDANCE TOMOGRAPHY METHOD TO DETECT AND TRACK FRACTURES IN A GELATIN MEDIUM

    … as a decrease in resistivity. A double linear array was used to take data for each of the fracture mechanisms and a two dimensional cross section was inverted from the data. The results were validated by visually inspecting the samples during the fracture event. It was found that although there …

    mtu Repository record for USE OF AN ELECTRICAL IMPEDANCE TOMOGRAPHY METHOD TO DETECT AND TRACK FRACTURES IN A GELATIN MEDIUM (opens in a new tab)

  11. Deep Learning Applications in Light-based Ultrasound Imaging: Photoacoustic Microscopy, Photoacoustic Tomography, and Passive Cavitation Mapping

    … by coupling a digital model of a 512-element ring-array transducer with supervised deep learning deconvolution. In PCM, we use deep learning to characterize the complex interactions of cavitation collapses during kidney stone lithotripsy and generate predictive visualizations of stone material …

    duke Repository record for Deep Learning Applications in Light-based Ultrasound Imaging: Photoacoustic Microscopy, Photoacoustic Tomography, and Passive Cavitation Mapping (opens in a new tab)

  12. High energy gamma ray imaging

    … been investigated as candidates for the scattering detector in such a device. A model of a complete ring array Compton camera system has been used to evaluate performance. The data from the Monte Carlo model has been reconstructed to form images. The quality of the images generated have then …

    ucl Repository record for High energy gamma ray imaging (opens in a new tab)

  13. Acoustic non-destructive testing for wood : a thesis by publications presented in fulfillment of the requirements for the degree of Doctor of Philosophy in Engineering at Massey University, Albany, New Zealand

    … test is considered the gold standard for measuring the stiffness of wood. However, this method is destructive, costly and difficult to use. Non-destructive testing (NDT) techniques have therefore been developed to mitigate these issues. Acoustics is the most common NDT technique used to measure …

    massey Repository record for Acoustic non-destructive testing for wood : a thesis by publications presented in fulfillment of the requirements for the degree of Doctor of Philosophy in Engineering at Massey University, Albany, New Zealand (opens in a new tab)

  14. Fabrication technology and design for CMUTS on CMOS for IVUS catheters

    … micromachined ultrasonic transducer (CMUT) arrays for intravascular ultrasonic (IVUS) imaging along with the fabrication processes to allow for monolithic integration of CMUTs with custom CMOS electronics for improved performance. The IVUS imaging arrays include dual-ring arrays for …

    gatech Repository record for Fabrication technology and design for CMUTS on CMOS for IVUS catheters (opens in a new tab)

  15. Near field interactions in terahertz metamaterials

    … for condensed matter physics and optics engineering. From the physics perspective, advances in the generation and detection of THz radiation have opened the door for spectroscopic studies of a range of solid-state phenomena that manifest at THz frequencies. From an engineering perspective, THz …

    bu Repository record for Near field interactions in terahertz metamaterials (opens in a new tab)

  16. Development and feasibility assessment of open-UST: A low-cost, open-source, manufacturing framework for an ultrasound tomography research system

    … Having access to a physical UST transducer array in-house accelerates algorithm development, compared to relying solely on open databases of experimental data from other groups. Widely available UST hardware also allows new algorithms to be tested on real data from physical transducers, …

    ucl Repository record for Development and feasibility assessment of open-UST: A low-cost, open-source, manufacturing framework for an ultrasound tomography research system (opens in a new tab)

  17. Enhancing Photoacoustic Resolution Using Sparsity-Based Reconstruction

    … Working first with a linear ultrasound receive array, and then with a ring array, we reconstruct successive cross-sections of a target consisting of two crossed wires. In these experiments, we found sparsity-based reconstruction was able to super-resolve point sources. Two approaches for …

    alberta Repository record for Enhancing Photoacoustic Resolution Using Sparsity-Based Reconstruction (opens in a new tab)

  18. Electro-Optic Ring Resonators in Integrated Optics For Miniature Electric Field Sensors

    … electromagnetic fields using integrated optical ring resonator devices. The first topic involves the theoretical design, fabrication and demonstration of a new field sensor based on electro-optically (EO) active integrated optical ring resonators. The second topic addresses the problem of …

    ohiolink Repository record for Electro-Optic Ring Resonators in Integrated Optics For Miniature Electric Field Sensors (opens in a new tab)

Page 1 of 2