Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 287 for “"rms error"”
-
Reproducibility, Repeatability, and Precision: Digital Dental Model Registration with VIBE, T2 Space, and MP-RAGE Magnetic Resonance Imaging
… PRIMARY OUTCOME MEASURE: Root mean square (RMS) error in millimeters (mm) measured by 3dMD Vultus software. Clinical acceptability was designated as ≤ 0.5 mm RMS error. RESULTS: Inter-operator reproducibility of registrations with cbCT, T2 Space, VIBE, and MP-RAGE (i.e. imaging modalities) …
-
3D INDOOR STATE ESTIMATION FOR RFID-BASED MOTION-CAPTURE SYSTEMS
… proposed. For 3D motion with indoor multipath, RMS error before estimation is 71.99 cm, in which 34.99 cm in xy- plane and 62.92 cm along z- axis. After NLE estimation using RF signal combined with IMU data, RMS error of 3D coordinates decreases to 31.90 cm, with 22.50 cm in xy- plane and 22.61 …
-
Modelling Breast Tissue Mechanics Under Gravity Loading
… predicted surface deformations with an average RMS error of 1.5 mm +/- 0.2 mm and tracked internal marker locations with an average RMS error of 1.4 mm +/- 0.7 mm. A novel method was then developed to determine the reference configuration of a body, when given its mechanical properties, boundary …
-
Aukštesnės eilės akies aberacijų tyrimas prieš ir po miopijos ir astigmatizmo korekcijos LASEK būdu /
… aberrometer WASCA (COAS). Total HOA RMS error and individual the 3rd and 4th orders signed Zernike polynomials terms readings were compared. Total HOE RMS and individual Zernike polynomial coefficients were scaled to a 5 mm pupil. The patients were asked to evaluate subjectively their …
-
Investigating the empirical relationship between oceanic properties observable by satellite and the oceanic pCO?
… fourth order equation yields a Root Mean Square (RMS) error of 15.39 μatm (on the estimation of pCO2) with latitude excluded as variable and a RMS error of 8.797 μatm with latitude included as variable. Radial basis function (RBF) interpolation is another method that is used to determine the …
-
An Evaluation of Female Arm Strength Predictions based on Hand Location, Arm Posture and Force Direction
… explaining 75.4% of the variance, with an RMS error of 9.1 N, compared to an explained variance of 67.3% and an RMS error of 10.5 N without those postural variables. A comparison was also made between the empirical strength data from this thesis and the outputs from the University of …
-
Differential Evolution: A Global Optimization Framework For Marker Registration and Scaling Musculoskeletal Models
… robustness. The framework achieved an average RMS error of 0.77 cm in normal gait trials, representing a 44% improvement in RMS error over previous optimization methods (1.38 cm) and a 70% improvement over manual scaling (2.58 cm). This approach significantly reduces the need for expert …
-
A Virtual Framework for Semi-Autonomous Robotic Surgery using Real-Time Spatial Mapping
… tracking task. Performance was measured using RMS error (deviation from ideal path), actual path length, and time to complete the task. It was found that beyond about 1.5 seconds the task difficulty increased substantially, as reflected by increasing RMS error. Furthermore, efficiency was …
-
Repeatability, Reproducibility and Precision: Digital Dental Model Registration with Magnetic Resonance Imaging
… PRIMARY OUTCOME MEASURE: Root mean square (RMS) error in millimeters (mm) measured by 3dMD Vultus Software. Clinical acceptability was deemed as ≤ 0.5 mm RMS error. RESULTS: Repeatability of registrations between CBCT and MRI, as measured by RMS error, found no statistical significance …
-
Neuromuscular Reflex Control for Prostheses and Exoskeletons
… of perturbed walking, in which we minimized the error between the torque produced by our controller and the standard torque trajectories observed in the able-bodied experiments. In simulations, we then compare the VMR controller to a four-phase impedance controller. For both controllers the …
-
Parameter optimization in simplified models of cardiac myocytes
… and reproduces the action potential waveforms of individual cardiac myocytes. It incorporates three time-dependent ionic currents and an additional time-independent leakage current. The formulation of the three time-dependent ionic currents is based on 4-state Markov schemes with state …
-
Electrocortical Output and Hemispheric Contributions to the Alert State During a Sustained Attention Task
… and performance, measured as Root Mean Square (RMS) error, were recorded from the subjects during trials. RMS error was used to assess performance differences between preferred/non-preferred hand. Task mode switches were used to analyze differences between positive/negative feedback, …
-
Método genérico para estimação e modelagem do erro RMS em dados de profundidade de sensores para visão 3D
… that estimate depth data, they may contain errors. In this work, we present the design and implementation of a generic method for estimating the RMS error in depth data provided by any device, capable of generating data of type RGB-D, that is, an image and a depth map Same time. To verify …
-
Rattlesnake nanoactuator - a precision high speed closed loop linear actuator with capacitive sensor
… range of travel of ±1mm with a steady state RMS error of 62nm at a closed loop bandwidth of 3.5kHz, a typical tracking error of hundreds of nanometers (dependent on the waveform shape) and a maximum error in the range of 1 − 10μm. The stiffness of the system at 10Hz is 4N/μm and the actuator …
-
Analysis and fabrication of paraboloidal CFRP sandwich mirrors.
… optical quality better than 30 microns in figure RMS error. A parametric study on composite sandwich mirrors was conducted by using finite element analysis as well as optical analysis. The factors covered the cell sizes, core materials, core thicknesses, face layups, and support configurations. …
-
A Comparison of the Accuracy of Measurement of Urine Thiocyanate by Spectrophotometry and Ion Chromatography in a Population Without Known Exposure to Cyanide
… mean UTC level by SP was 16.84 (σ = 9.78). The RMS error was 8.06 for IC. The RMS error was 60.31 for SP. Three laboratories perform approximately 2400 UTC tests yearly in the US. Conclusions: The UTC testing by NMS in 1996 using the SP method overestimated levels.
-
Classical Modeling of a Phosphate Molecule (Including 3-D Computer Graphics Display)
An investigation is made of the classical force terms necessary to model adequately the structure and interatomic forces of the phosphate molecule. The two principal considerations chosen for use in judging the performance of models were: 1. Agreement with empirical spectral data on normal mode …
-
The Accuracy of Measuring Lumbar Vertebral Displacements Using a Dynamic MRI Sequence
… accuracy compared to the actual displacements (RMS error = 0.77 mm) and relative to the regression (SEE = 0.61 mm). The rotational measurements have increased errors compared to the actual displacements (RMS error = 4.230) and relative to the regression (SEE = 1.97°). Both translational (average …
-
Extension to Multiple Species of a Two-Equation Turbulence Model for High Speed Flows
… simulation, the surface pressure has a maximum error of 63% in the separation region, less than 5% error after the flow reattaches, and an RMS error of 17.2%, all of which are less than those of Wind-US and Cobalt. For the compression corner case, the surface pressure has a maximum error of 27% …
-
S-wave velocity estimation using converted-wave VSP data
… inversion results are slightly different: the RMS error between the true velocity and the inverted velocity varies from 1 m/s to 10 m/s for different initial models. The second test, with random noise, explores the sensitivities of results to errors in picked traveltimes. Results show that the …
Page 1 of 15