Results 1 to 20 of 22 for “"robotic catheter"”

  1. Design of an Ultrasound-Guided Steerable Robotic Catheter for Aortic Interventions

    … in the femoral artery to insert a steerable catheter, and real time x-ray imaging provides guidance as the surgeon maneuvers it to a target site. A variety of interventional devices, such as stents, grafts, and coils can then be delivered through a catheter to reach the treatment area. While …

    mit Repository record for Design of an Ultrasound-Guided Steerable Robotic Catheter for Aortic Interventions (opens in a new tab)

  2. PERCEPTION AND CONTROL OF AN MRI-GUIDED ROBOTIC CATHETER IN DEFORMABLE ENVIRONMENTS

    For the last decade, robotic catheters have emerged as a promising technology for catheter ablation. The development of magnetic resonance image (MRI) guided robotic catheters is complicated by the need to track the position and orientation of these instruments within the MRI scanner, accurate …

    ohiolink Repository record for PERCEPTION AND CONTROL OF AN MRI-GUIDED ROBOTIC CATHETER IN DEFORMABLE ENVIRONMENTS (opens in a new tab)

  3. A novel approach to actuate soft robotic catheter via magnetic actuation method

    … within the human chest using a soft magnetic catheter by enhancing the robot workspace and reducing the required magnetic field strength. By increasing the concentration of NdFeB nanoparticles, we successfully decreased the necessary magnetic field. Our proposed methods include utilizing a …

    whiterose Repository record for A novel approach to actuate soft robotic catheter via magnetic actuation method (opens in a new tab)

  4. Integrated magnetic localization sensing and actuation of steerable robotic catheter for Peripheral Arterial Disease treatment

    Magnetically Steerable Robotic Catheters (MSRC) exhibit potential in treating Peripheral Arterial Diseases (PAD) through the precise steering of a catheter tip via magnetic actuation. PAD, characterized by the narrowing of blood vessels, affects approximately 6.5 million people age 40 and older in …

    texas Repository record for Integrated magnetic localization sensing and actuation of steerable robotic catheter for Peripheral Arterial Disease treatment (opens in a new tab)

  5. Dynamic Modeling and Motion Control of a Pneumatic Soft Robotic Catheter Using Neural Koopman Operator

    Catheter-based interventions are widely used for the diagnosis and treatment of cardiac diseases. Recently, robotic catheters have attracted attention for their ability to improve precision and stability over conventional manual approaches. However, accurate modeling and control of soft robotic …

    jhu Repository record for Dynamic Modeling and Motion Control of a Pneumatic Soft Robotic Catheter Using Neural Koopman Operator (opens in a new tab)

  6. Integration of Actuation, Imaging, and Control of a Magnetically Actuated, Magnetic Resonance Imaging-Guided Robotic Catheter

    <p>Catheter ablation is an established treatment for refractory arrhythmia. Robotic catheters operating under MRI guidance may offer enhanced control, visualization, and safety. Catheter actuation with current-carrying microcoils is fast and responsive. However, it leads to large void artifacts in …

    ohiolink Repository record for Integration of Actuation, Imaging, and Control of a Magnetically Actuated, Magnetic Resonance Imaging-Guided Robotic Catheter (opens in a new tab)

  7. Design of a Precision, Adjustable Current Source for Use In an MRI-Based Robotic Catheter System

    Heart catheter ablation surgeries often employ X-ray fluoroscopy to image the position of the catheter during the procedure. Magnetic Resonance Imaging (MRI) can be used to image the catheter position in real-time without exposing a patient to ionizing radiation while providing excellent soft …

    ohiolink Repository record for Design of a Precision, Adjustable Current Source for Use In an MRI-Based Robotic Catheter System (opens in a new tab)

  8. A MAGNETICALLY-ACTUATED ROBOTIC CATHETER FOR ATRIAL FIBRILLATION ABLATION UNDER REAL-TIME MAGNETIC RESONANCE IMAGING GUIDANCE

    … and analysis of a magnetically actuated robotic intravascular catheter for performing atrial fibrillation ablation under magnetic resonance imaging guidance. Specifically:A three dimensional deflection model of a steerable catheter in free space is proposed and experimentally validated …

    ohiolink Repository record for A MAGNETICALLY-ACTUATED ROBOTIC CATHETER FOR ATRIAL FIBRILLATION ABLATION UNDER REAL-TIME MAGNETIC RESONANCE IMAGING GUIDANCE (opens in a new tab)

  9. Radio-Frequency Response Characterization and Design of Actuation Coils for a Novel MRI Guided Robotic Catheter System

    … procedures employ cardiac ablation catheters guided using x-ray fluoroscopy imaging, which generates restricted two-dimensional images of the heart, and exposes the patient to a high dose of radiation. Three-dimensional catheter position data can be obtained and radiation exposure …

    ohiolink Repository record for Radio-Frequency Response Characterization and Design of Actuation Coils for a Novel MRI Guided Robotic Catheter System (opens in a new tab)

  10. Design and Prototyping of a Coil-Driven Actuated Catheter for Use in an MRI-Guided Robotic Catheter System

    … Traditional treatment involves cardiac ablation catheters guided by x-ray fluoroscopy, which provides limited two-dimensional heart images and subjects patients to substantial radiation. Utilizing magnetic resonance imaging (MRI) in these procedures offers three-dimensional catheter visualization …

    ohiolink Repository record for Design and Prototyping of a Coil-Driven Actuated Catheter for Use in an MRI-Guided Robotic Catheter System (opens in a new tab)

  11. Design and Testing of a Switch Mode, Precisely Adjustable Current Driver For Use in an MRI-Compatible Robotic Catheter System

    … adjustable current driver for an MRI guided robotic catheter system intended for cardiac ablation and similar procedures requiring a directed catheter in an MRI. The proposed system uses a modular, PWM-based architecture, with each channel capable of sourcing ±2 A with fine resolution, and …

    ohiolink Repository record for Design and Testing of a Switch Mode, Precisely Adjustable Current Driver For Use in an MRI-Compatible Robotic Catheter System (opens in a new tab)

  12. Real-Time Kinematic Modeling of Magnetically-Actuated MRI-Guided Robotic Intravascular Cardiac Catheter

    … control of the magnetically-actuated MRI-guided robotic intravascular cardiac catheter. The robotic catheters are embedded with current carrying coil actuators. The actuator contains one axial coil, and two orthogonal side coils. The catheter is steered by the magnetic moments generated on a set …

    ohiolink Repository record for Real-Time Kinematic Modeling of Magnetically-Actuated MRI-Guided Robotic Intravascular Cardiac Catheter (opens in a new tab)

  13. Interaction Control Under Uncertainty For an MRI-Actuated Robotic Intravascular Cardiac Catheter

    … beating heart motions are major concerns during catheter ablation procedures. Maintaining a stable and safe contact on the desired ablation point is essential for achieving effective lesions during the ablation procedure. This dissertation aims to provide a comprehensive solution to the …

    ohiolink Repository record for Interaction Control Under Uncertainty For an MRI-Actuated Robotic Intravascular Cardiac Catheter (opens in a new tab)

  14. Probabilistic Calibration and Catheter Tracking with Robotic Systems

    A significant boost in robotics technology has been observed in recent years and more and more tasks are being automated by robots such as robotic surgery, autonomous driving, package delivery, etc. Not only has the precision of robots been improved, but the number of robots involved in a specific …

    jhu Repository record for Probabilistic Calibration and Catheter Tracking with Robotic Systems (opens in a new tab)

  15. A transcatheter annuloplasty band system for tricuspid valve repair

    … treatment options. Here we present a transcatheter annuloplasty band that advances the technology of minimally-invasive treatment options for patients with tricuspid regurgitation. The band and deployment system work in conjunction with a soft robotic catheter that was previously developed …

    bu Repository record for A transcatheter annuloplasty band system for tricuspid valve repair (opens in a new tab)

  16. DESIGN OF A HIGH-CURRENT TRANSCONDUCTANCE AMPLIFIER FOR AN MRI-GUIDED ROBOTIC HEART CATHETER

    … issues. Current procedures utilize ablation catheters which are positioned using x-ray fluoroscopy imaging, exposing the patient and surgeon to a high dose of radiation. Often the ablation procedure must be performed more than once to eliminate atrial fibrillation. Radiation exposure can be …

    ohiolink Repository record for DESIGN OF A HIGH-CURRENT TRANSCONDUCTANCE AMPLIFIER FOR AN MRI-GUIDED ROBOTIC HEART CATHETER (opens in a new tab)

  17. Force Estimation and Shape Reconstruction of Soft Robots in Contact with Fluid Flow: theory and experiment

    This thesis explores two significant aspects of robotic-assisted surgeries. The first part focuses on a procedure called Robotic Catheter Ablation, which utilizes robots to treat a heart condition known as Atrial fibrillation. The procedure aims to determine the contact force at the robot's tip …

    concordia

  18. Smart actuation and sensing for meso-scale surgical robotic systems

    … presents the development of meso-scale surgical robotics based on smart actuation and sensing for minimally invasive surgery (MIS). By replacing conventional straight tools by steerable surgical robots, surgical outcomes can potentially be improved due to more precise, stable, and flexible …

    gatech Repository record for Smart actuation and sensing for meso-scale surgical robotic systems (opens in a new tab)

  19. Design, Modeling, Imaging, and Control of a Robotically Steerable Transcatheter Delivery System

    … the most prevalent valvular heart disease. Transcatheter mitral valve repair (TMVr), increasingly preferred for nearly half of MR patients who are non-surgical candidates, currently utilizes manually operated devices that expose clinical staff to increased radiation, require experienced operators …

    gatech Repository record for Design, Modeling, Imaging, and Control of a Robotically Steerable Transcatheter Delivery System (opens in a new tab)

  20. Design and Redundant Control of Limited-Use Tendon-Driven Continuum Manipulators with a Passive Proximal Section

    … issues which arise when using tendon-driven robotic manipulators in medical applications. Two separable robots which overcome difficulties in actuation and sterilization were designed, fabricated, and tested. Both devices combat the difficulty of cleaning a robotic catheter after a procedure …

    tamu Repository record for Design and Redundant Control of Limited-Use Tendon-Driven Continuum Manipulators with a Passive Proximal Section (opens in a new tab)