Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 64 for “"robotic device"”.

  1. Development of a Robotic Device for the Physical Training of Human Upper Extremity

    This thesis focuses on the development of a robotic device to be used in parallel with observational learning techniques for facilitating the recovery of the upper limb in post-stroke patients. It has been shown in the existing observational learning literature that observational practice for the …

    tamu Repository record for Development of a Robotic Device for the Physical Training of Human Upper Extremity (opens in a new tab)

  2. Design of the rehabilitation glove : a soft wearable robotic device for repetitive hand rehabilitation therapy after a stroke

    … what could solve this major issue. The existing devices will be reviewed and robotic rehabilitation devices pointed as a solution for future post stroke recovery therapy. The concept of a soft robotic glove for hand rehabilitation, coupling a flexible structure with a cable-driven actuation will …

    strathclyde Repository record for Design of the rehabilitation glove : a soft wearable robotic device for repetitive hand rehabilitation therapy after a stroke (opens in a new tab)

  3. Investigating the Effects of a Task-Specific Fatigue Protocol on Hand Tracking Performance Using a Wrist Robotic Device

    … a 2:3 Lissajous curve using a haptic wrist robotic device (WristBot). This same curve was traced before the fatigue (baseline), during the fatigue protocol, and after the fatigue protocol. Post fatigue trials were completed at 0, 1, 2, 4, 6, 8, and 10 minutes after the cessation of the …

    brock Repository record for Investigating the Effects of a Task-Specific Fatigue Protocol on Hand Tracking Performance Using a Wrist Robotic Device (opens in a new tab)

  4. Improving classification of error related potentials using novel feature extraction and classification algorithms for an assistive robotic device

    … between the brain and an electronic device. To enhance the symbiotic interface between the person and BCI its accuracy and robustness should be improved across all age groups. This thesis aims to address the above-mentioned issue by developing a novel feature extraction algorithm and …

    whiterose Download PDF for Improving classification of error related potentials using novel feature extraction and classification algorithms for an assistive robotic device (opens in a new tab)

  5. Development of Robotic Medical Devices: Applications in Tele-palpation, Training, and in Orthognathic Surgery

    … the healthcare landscape by applying robotic technologies across several aspects of patient care. Though medical robots can be classified based on several aspects such as field of application, target anatomical region or surgical and non-surgical robots, an important classification is …

    ucf Repository record for Development of Robotic Medical Devices: Applications in Tele-palpation, Training, and in Orthognathic Surgery (opens in a new tab)

  6. Controller Synthesis of Multi-Axial Robotic System Used for Wearable Devices

    Wearable devices are commonly used in different fields to help improving performance of movements for different groups of users. The long-term goal of this study is to develop a low-cost assistive robotic device that allows patients to perform rehabilitation activities independently and reproduces …

    wvu Repository record for Controller Synthesis of Multi-Axial Robotic System Used for Wearable Devices (opens in a new tab)

  7. An adaptive 4-week robotic training program of the upper limb for persons with multiple sclerosis

    … and this process can be optimized with robotic devices. The repetitive, reproducible and high dose motor movements that can be delivered by robotics have shown positive results in functional outcomes in stroke patients. However, there is little research on robotic neurorehabilitation for …

    brock Repository record for An adaptive 4-week robotic training program of the upper limb for persons with multiple sclerosis (opens in a new tab)

  8. Investigating the Effects of Subclinical Neck Pain, Cervical Treatment, and Neck Muscle Fatigue on Wrist Joint Position Sense

    … two wrist proprioception sessions using a haptic robotic device separated by an isometric cervical extensor fatigue protocol. On the second day participants performed an additional two proprioception sessions, this time separated either by a neck treatment (pain group) or 20 minutes of rest …

    brock Repository record for Investigating the Effects of Subclinical Neck Pain, Cervical Treatment, and Neck Muscle Fatigue on Wrist Joint Position Sense (opens in a new tab)

  9. Parameter analysis for robotic assessment of impairments in reaching due to stroke

    … of a reaching task on a bi-lateral upper limb robotic device (KINARM), developed by one of our team members (Stephen Scott), to assess upper limb impairments due to stroke. Control and stroke subjects were instructed to reach with both arms on the robotic device to illuminating spatial targets …

    queens Repository record for Parameter analysis for robotic assessment of impairments in reaching due to stroke (opens in a new tab)

  10. fMRI-compatible robotic wrist rehabilitation manipulandum: design, prototyping, and implementation

    … rehabilitation necessary for daily activities. Robotic rehabilitation devices come with engaging interfaces, showing promise in sustaining patient engagement. They offer encouragement for addressing upper extremity motor challenges. The contributions of this thesis lie in developing an …

    manitoba Repository record for fMRI-compatible robotic wrist rehabilitation manipulandum: design, prototyping, and implementation (opens in a new tab)

  11. Rehabilitation in Stroke-Related Flexor Synergy

    … in deltoid loading can decrease flexor synergy. Robotic rehabilitation has the ability to allow for reduced deltoid loading while assisting or constraining joints along the arm to increase rehabilitation outcomes. The effects of higher degree of freedom low impedance robotics needs to be tested …

    vcu Repository record for Rehabilitation in Stroke-Related Flexor Synergy (opens in a new tab)

  12. Development of a Novel Amphibious Locomotion System for use in Intra-Luminal Surgical Procedures

    … was to develop a locomotion system for use on a robotic device that can traverse a liquid filled colon for atraumatic inspection and biopsy tasks. The PhD was undertaken as part of a larger two-centre EU project, which aimed to bring about a change in the way colonoscopy is done by moving to …

    whiterose Download PDF for Development of a Novel Amphibious Locomotion System for use in Intra-Luminal Surgical Procedures (opens in a new tab)

  13. Integration of multirate heteroceptive sensor data in robotic system servo-loops

    … feedback about the internal state of the robotic device) is already used to close the feedback loop. Increased robustness is achieved through the dynamic reconfiguration of the sensing subsystem on fault occurrence. The smooth transition between the different sensing subsystem …

    ubc Repository record for Integration of multirate heteroceptive sensor data in robotic system servo-loops (opens in a new tab) Download PDF for Integration of multirate heteroceptive sensor data in robotic system servo-loops (opens in a new tab)

  14. Subject Adaptive Control Paradigms for Robotic Rehabilitation

    … to deliver intensive and repetitive therapy, robotic devices are increasingly being used for the rehabilitation of neurologically impaired individuals. However, not every robotic device or therapy protocol has been shown to promote plasticity-mediated recovery. It is necessary that the robotic …

    rice Repository record for Subject Adaptive Control Paradigms for Robotic Rehabilitation (opens in a new tab)

  15. Development of a home-based Computer Assisted Arm Rehabilitation (hCAAR) device for upper limb exercises in stroke patients

    Home-based robotic technologies may offer the possibility of self-directed upper limb exercise after stroke as a means of increasing the intensity of rehabilitation treatment. The aim of this research project was to develop and evaluate a robotic device hCAAR that can be used independently at home …

    whiterose Download PDF for Development of a home-based Computer Assisted Arm Rehabilitation (hCAAR) device for upper limb exercises in stroke patients (opens in a new tab)

  16. Mechatronic design of autonomous underwater vehicles for confined spaces

    … pipelines, it is often desired to have a robotic device that can navigate the complex structure to carry inspection to maintain the integrity of these infrastructures. In this work, an attempt to design an untethered micro autonomous underwater vehicle, mAUV, is conducted. The mechanical, …

    gatech Repository record for Mechatronic design of autonomous underwater vehicles for confined spaces (opens in a new tab)

  17. iART: An intelligent assistive robotic therapy system for home-based stroke rehabilitation

    … of iART : an Intelligent Assistant for Robotic Therapy. iART is a robot-assisted therapy system designed for home-based upper limb stroke rehabilitation. Stroke is the leading cause of motor impairments and serious long term disability in the United States. These impairments severely …

    uiuc Repository record for iART: An intelligent assistive robotic therapy system for home-based stroke rehabilitation (opens in a new tab)

  18. Μεθοδολογίες προγραμματισμού κίνησης σε νευρο-ρομποτικά συστήματα

    Conceptually, a robotic device may be interfaced with a human neural system. Such a robot processes electro myographic activity (EMG signals) and uses it in the control loop that moves the mechanical links. In realizing such a neuro-robotic system, several challenges need to be met. One such …

    greece Repository record for Μεθοδολογίες προγραμματισμού κίνησης σε νευρο-ρομποτικά συστήματα (opens in a new tab)

  19. Development of a control system to determine influence of rolling resistance in manual wheelchair dynamics and mechanical efficiency

    … Anatomical Model Propulsion System (AMPS) is a robotic device to test manual wheelchairs with better repeatability than human subjects, helping to identify the effect of resistive forces. It uses electric motors to apply torque directly to the rear wheel handrims. In this thesis, a control …

    gatech Repository record for Development of a control system to determine influence of rolling resistance in manual wheelchair dynamics and mechanical efficiency (opens in a new tab)

Page 1 of 4