Showing 1 to 20 of 27 for “"rocking wall"”.

  1. Study on Interaction between Rocking-Wall System and Surrounding Structure

    Reinforced concrete (RC) special structural walls have proven to be an effective means of resisting lateral loads in structural systems. They are detailed to dissipate energy through the development of plastic hinge regions. Although few buildings with special structural walls have collapsed in …

    umn Repository record for Study on Interaction between Rocking-Wall System and Surrounding Structure (opens in a new tab)

  2. Comprehensive evaluation of multistrand post-tensioning anchorage systems for seismic resilient rocking wall structures

    … anchorage systems for use in seismic resilient rocking wall structures. The testing program encompassed two anchorage manufacturers, two anchorage alignment configurations, and two wedge geometries under both monotonic and cyclic loading.

    umn Repository record for Comprehensive evaluation of multistrand post-tensioning anchorage systems for seismic resilient rocking wall structures (opens in a new tab)

  3. Optimized seismic design and dynamic response analysis of mass timber rocking wall lateral system

    … of lateral resisting system called mass timber rocking walls can potentially improve the resilience of the building during earthquakes. This system utilizes mass timber products as wall panels and unbonded post-tension bars to tie the rocking panel to the foundation. The rocking wall lateral …

    colo-mines Repository record for Optimized seismic design and dynamic response analysis of mass timber rocking wall lateral system (opens in a new tab)

  4. Seismic performance of controlled outrigger rocking wall system with different types of energy dissipation devices

    Controlled Outrigger Rocking Wall (CORW) system is a novel earthquake resilient system which combines reinforced concrete wall with controlled rocking base hinge and outrigger system. At the end of the rocking base and the outrigger, different dampers are used to provide the supplemental energy …

    ubc Repository record for Seismic performance of controlled outrigger rocking wall system with different types of energy dissipation devices (opens in a new tab) Download PDF for Seismic performance of controlled outrigger rocking wall system with different types of energy dissipation devices (opens in a new tab)

  5. Investigation of Modular Cross-Laminated Timber Rocking Walls and Rocking Wall -- Light-Frame Shear Wall Dual Systems for Seismic Resilience

    … design of post-tensioned cross-laminated timber rocking walls (PT-CLT-RW) for resilient wood construction. This research focuses on experimental, analytical, and numerical investigations into PT-CLT-RW systems, both as stand-alone and as a dual lateral force resisting systems (LFRS) with wood …

    vt Repository record for Investigation of Modular Cross-Laminated Timber Rocking Walls and Rocking Wall -- Light-Frame Shear Wall Dual Systems for Seismic Resilience (opens in a new tab)

  6. Seismic Response of Moment Resisting Frames Coupled with Rocking Walls

    … response of yielding structures coupled with rocking walls. This topic is of major significance in the design of tall moment-resisting buildings, since during recent major earthquakes several tall, moment-resisting frames that had been designed in an accordance to the existing seismic code …

    ucf Repository record for Seismic Response of Moment Resisting Frames Coupled with Rocking Walls (opens in a new tab)

  7. Studies of nonstructural components in tall mass timber buildings with cross-laminated timber rocking walls

    … Post-tensioned cross-laminated timber (CLT) rocking walls are being developed as a seismic resilient lateral load resisting system for mass timber building construction. However, achieving whole building resiliency heavily depends on the resiliency of nonstructural systems, as they comprise …

    unr Repository record for Studies of nonstructural components in tall mass timber buildings with cross-laminated timber rocking walls (opens in a new tab)

  8. Seismic Behavior of Tall Rocking Mass Timber Walls

    … building material. Post-tensioned mass timber rocking wall lateral force-resisting systems have made fully mass timber buildings feasible for high seismic areas. The inherent re-centering behavior of these systems provides an opportunity to design for enhanced seismic objectives, creating a …

    washington Repository record for Seismic Behavior of Tall Rocking Mass Timber Walls (opens in a new tab)

  9. Resilience-based seismic design based on time-to-functionality for tall mass timber buildings

    … mass timber SFRS (a cross laminated timber [CLT] rocking wall), developed as a part of the Natural Hazards Equipment Research Infrastructure (NHERI) TallWood project, to demonstrate the resilience capabilities of the system. While the CLT rocking wall SFRS demonstrated excellent resilience …

    colostate Repository record for Resilience-based seismic design based on time-to-functionality for tall mass timber buildings (opens in a new tab)

  10. Base-Modified Post-Tensioned Rocking Walls for Tailored Seismic Response and Damage Reduction

    … main structural components. The post-tensioned rocking wall is one of the novel systems that has shown promising results by limiting bending and shear stress on the wall via post-tensioned bars/strands and rocking. However, despite the many benefits of this system - such as redirecting the …

    washington Repository record for Base-Modified Post-Tensioned Rocking Walls for Tailored Seismic Response and Damage Reduction (opens in a new tab)

  11. Construction and seismic testing of a resilient two-story mass timber structure with cross laminated rocking walls

    … structure with a resilient post-tensioned rocking wall lateral system made from cross laminated timber (CLT) product. The post-tensioned rocking walls helped to dissipate seismic forces while allowing the other parts of the structure to remain damage-free through multiple seismic events. …

    colo-mines Repository record for Construction and seismic testing of a resilient two-story mass timber structure with cross laminated rocking walls (opens in a new tab)

  12. Experimental investigation of long term and lateral load behavior of CLT shear walls for mid-rise wood buildings

    … buildings. Traditional Light Wood Frame Shear Wall system used in residential building construction in the U.S. cannot be used to construction tall building as it fails to provide necessary strength and stiffness. Mass timber panel such as Cross-Laminated Timber has been recognized as a …

    alabama Repository record for Experimental investigation of long term and lateral load behavior of CLT shear walls for mid-rise wood buildings (opens in a new tab)

  13. Seismic performance evaluation of full-scale mass timber structures: comparative insights from tall and mid-rise shake table test programs

    … incorporated a post-tensioned mass timber rocking wall system, a low-damage gravity framing system, and drift-compatible non-structural components. Standing 34.4 m (113 ft) tall with a uniform 84 m² (900 ft²) floor plan, it was constructed and tested on the NHERI@UCSD outdoor shake table in …

    colostate Repository record for Seismic performance evaluation of full-scale mass timber structures: comparative insights from tall and mid-rise shake table test programs (opens in a new tab)

  14. Seismic performance of unbonded post-tensioned precast wall systems subjected to shake table testing

    … of unbonded post-tensioned precast concrete rocking walls both with and without additional hysteretic energy dissipaters. These wall systems dissipate the seismic input energy mainly through impacts of the wall on top of the foundation during rocking as well as the external hysteretic …

    iastate Repository record for Seismic performance of unbonded post-tensioned precast wall systems subjected to shake table testing (opens in a new tab)

  15. Seismic performance of unbonded post-tensioned precast wall systems subjected to shake table testing

    … of unbonded post-tensioned precast concrete rocking walls both with and without additional hysteretic energy dissipaters. These wall systems dissipate the seismic input energy mainly through impacts of the wall on top of the foundation during rocking as well as the external hysteretic …

    iastate Repository record for Seismic performance of unbonded post-tensioned precast wall systems subjected to shake table testing (opens in a new tab)

  16. Design and construction of tall mass timber buildings with resilient post-tensioned mass timber rocking walls

    … in the form of post-tensioned mass timber rocking walls, have been proven to be a resilient system that performs well under seismic loading with sufficient strength and stiffness. However, the use of post-tensioned mass timber rocking walls as a lateral force-resisting system has been …

    colo-mines Repository record for Design and construction of tall mass timber buildings with resilient post-tensioned mass timber rocking walls (opens in a new tab)

  17. Uncertainty in the Seismic Response of Freestanding Structures

    … dominated by rigid body motion, which includes rocking, sliding, slide-rocking, and overturning, during earthquake excitation. This class of structures includes historical unreinforced masonry civil structures, modern rocking wall and column systems, mechanical and electrical equipment, and also …

    nebraska Repository record for Uncertainty in the Seismic Response of Freestanding Structures (opens in a new tab)

  18. Large-Scale Dynamic Testing of Rocking Cross Laminated Timber Walls

    … and steel. Using CLT panels in a post-tensioned rocking wall system shows great potential for creating reliable, cost-effective, and rapidly constructible ductile seismic load resisting systems. The design of these systems are supplemented with replaceable steel U-shaped flexural plate energy …

    washington Repository record for Large-Scale Dynamic Testing of Rocking Cross Laminated Timber Walls (opens in a new tab)

  19. Development of an innovative earthquake-resilient reinforced concrete core wall system

    … an earthquake-resilient reinforced concrete core wall system, named the controlled rocking outrigger core wall (CROCW). In the CROCW system, along one principal axis is a controlled outriggered rocking wall (CORW), where an outrigger is situated at the roof and the base is designed to rock. …

    ubc Repository record for Development of an innovative earthquake-resilient reinforced concrete core wall system (opens in a new tab) Download PDF for Development of an innovative earthquake-resilient reinforced concrete core wall system (opens in a new tab)

  20. Experimental and FEA Study of Structural Behavior of CLT Shear Walls for Wood Building Applications

    … codes, different categories of CLT shear wall systems need to be fully characterized and novel solutions must be implemented to overcome the limitations of existing timber systems. This dissertation addresses analytical modelling of unbonded post-tensioned (PT) CLT rocking wall (CLTRW) …

    alabama Repository record for Experimental and FEA Study of Structural Behavior of CLT Shear Walls for Wood Building Applications (opens in a new tab)