Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"rotary file"”.

  1. A Comparison of Flexural Fracture of Three Different Nickel-Titanium Rotary File Systems

    … of rotations to failure of three different rotary file systems. ProFile, Sequence, and Liberator files in sizes 25 and 40 with 0.04 taper were divided into groups of five and rotated against a grooved metal block mounted to a Universal testing machine at 31 and 34 degrees. Each file was …

    vcu Repository record for A Comparison of Flexural Fracture of Three Different Nickel-Titanium Rotary File Systems (opens in a new tab)

  2. Comparative Evaluation of Three Endodontic Rotary File Systems in S-shaped Root Canals: An In-depth Analysis

    Objective: This study compares three endodontic file systems—XP‐3D Shaper⁺, EdgeFile X7 and WaveOne Gold in S‐shaped simulated canals in resin blocks. It aimed to quantify canals volumetric changes post‐instrumentation to guide clinical selection of a system that preserves tooth structure while …

    vcu Repository record for Comparative Evaluation of Three Endodontic Rotary File Systems in S-shaped Root Canals: An In-depth Analysis (opens in a new tab)

  3. Effect of lubricant viscosity on the time required for separated rotary file removal in curved root canals

    … used to aid in the removal of separated rotary files by ultrasonic activation in teeth with curved roots. METHODS: Eighty extracted human teeth with visible curved roots were accessed and prepared with rotary instrumentation. After the evaluation by cone-beam CT, root canals with a …

    bu Repository record for Effect of lubricant viscosity on the time required for separated rotary file removal in curved root canals (opens in a new tab)

  4. Evaluation of Cervical Dentin Removal After Orifice Shaping in Maxillary Premolars: A Micro CT Study

    … Gates Glidden Drills, ProTaper SX, and a 20-06 Rotary File. Methods: A total of 24 extracted two-rooted maxillary first premolars were divided into three groups (n=8) and were coronally flared using either Gates-Glidden Drills, ProTaper Gold SX, or a 20-06 Brasseler Endosequence CM Rotary File. …

    vcu Repository record for Evaluation of Cervical Dentin Removal After Orifice Shaping in Maxillary Premolars: A Micro CT Study (opens in a new tab)

  5. Influence of Kinematics of Nickel-Titanium Instruments on Root Canal Preparations of Dental Students –A Micro CT Evaluation

    … Over the last decades, nickel-titanium (NiTi) rotary instruments have enhanced the quality of root canal shaping for clinicians. Currently, two common NiTi rotary instruments, WaveOne Gold and ProTaper Gold, function by two different forms of kinematics: a reciprocating and rotating movement …

    temple Repository record for Influence of Kinematics of Nickel-Titanium Instruments on Root Canal Preparations of Dental Students –A Micro CT Evaluation (opens in a new tab)

  6. The Effect of Operational Speed on the Fracture of Nickel Titanium Rotary Instruments

    Numerous nickel titanium rotary file systems have been introduced in recent years. The recommended speed at which these files are to be operated varies widely between manufacturers. The purpose of this study was to test the number of rotations to fracture of NiTi rotary files when operated at …

    vcu Repository record for The Effect of Operational Speed on the Fracture of Nickel Titanium Rotary Instruments (opens in a new tab)

  7. Effects of irrigation and agitation on apical vapor lock : an ex-vivo study

    … Vortex Blue 25/04 or ProTaper Gold F2 (25/08) rotary files. Presence of apical vapor lock was detected radiograph-ically using a contrast mixture (sodium hypochlorite & cesium chloride) as the irrigant. Manual dynamic agitation with 50 strokes of a well fitting gutta percha cone was performed …

    ubc Repository record for Effects of irrigation and agitation on apical vapor lock : an ex-vivo study (opens in a new tab) Download PDF for Effects of irrigation and agitation on apical vapor lock : an ex-vivo study (opens in a new tab)

  8. Evaluation of canal instrumentation using GT-Series-X™ versus ProSystem GT™

    … of root canal treatment. Two recently introduced rotary instrument systems are ProSystem GT™ and GT-Series-X™. The aim of this study is to compare the ability of two nickel- titanium rotary file systems, GT-Series-X™, and ProSystem GT™, to maintain the original canal path using a split-mold design …

    ubc Repository record for Evaluation of canal instrumentation using GT-Series-X™ versus ProSystem GT™ (opens in a new tab) Download PDF for Evaluation of canal instrumentation using GT-Series-X™ versus ProSystem GT™ (opens in a new tab)

  9. COMPARATIVE ANALYSIS OF TORSIONAL STRENGTH BETWEEN PROFILE® GT® AND GT® SERIES X(TM) NICKEL TITANIUM ROTARY INSTRUMENTS

    … by the twisting of two nickel titanium (NiTi) rotary file systems. The Profile® GT® (GT) and the GT® Series X(TM) (GTX) files were tested to analyze the maximum torsional strength and the maximum angular deflection at the time of separation of the files. For each system, ten new files were …

    vcu Repository record for COMPARATIVE ANALYSIS OF TORSIONAL STRENGTH BETWEEN PROFILE® GT® AND GT® SERIES X(TM) NICKEL TITANIUM ROTARY INSTRUMENTS (opens in a new tab)

  10. Quality of root filling by three different techniques in teeth after minimal root canal preparation and the GentleWave cleaning

    … instrumented to size 20/.04 taper using hand K-files, and a Vortex Blue NiTi rotary file. Sodium hypochlorite (NaOCl) 6% was used in-between each instrument insertion and the canals were finally cleaned using a 7.5 min irrigation by the GW. The samples were scanned with micro-CT using a voxel …

    ubc Repository record for Quality of root filling by three different techniques in teeth after minimal root canal preparation and the GentleWave cleaning (opens in a new tab) Download PDF for Quality of root filling by three different techniques in teeth after minimal root canal preparation and the GentleWave cleaning (opens in a new tab)

  11. Impact of Access Cavity Design on Peri-Cervical Dentin Removal in 3D Printed Tooth Models

    … of this study was to evaluate the impact of rotary file instrumentation (TruNatomy and XP-Endo Shaper) on peri-cervical dentin removal, depending on access size. Materials and Methods Forty 3D printed mandibular first molars, with either a small or large access design, were instrumented using …

    u-pacific Repository record for Impact of Access Cavity Design on Peri-Cervical Dentin Removal in 3D Printed Tooth Models (opens in a new tab)

  12. COMPARING CYCLIC FATIGUE OF THE NEW GT® SERIES X(TM) FILES TO THE ENDO SEQUENCE™ ROTARY INSTRUMENTS

    … number of rotations to failure of two different rotary file systems, EndoSquence Brassler USA (Savannah, GA) and GT(TM) series X(TM). Files sizes 20,30,40 with 0.04, 0.06 tapers of GT series X and Endo Sequence files size and taper used were 20, 30, 40 with 0.04 and 0.06 taper. Like tip and …

    vcu Repository record for COMPARING CYCLIC FATIGUE OF THE NEW GT® SERIES X(TM) FILES TO THE ENDO SEQUENCE™ ROTARY INSTRUMENTS (opens in a new tab)

  13. Performance and Preference of Rotary Files by Pre-Doctoral Dental Students at Marquette School of Dentistry

    … and procedural mishaps using different NiTi rotary systems in the hands of unexperienced pre-doctoral dental students; 2) to gain an understanding of which rotary file system students subjectively prefer. Methods: Second year dental students (n=94) enrolled in preclinical endodontics received …

    marquette Repository record for Performance and Preference of Rotary Files by Pre-Doctoral Dental Students at Marquette School of Dentistry (opens in a new tab)

  14. Combined torsional and cyclic fatigue resistance of rotary endodontic files

    … to evaluate the impact of torque at the tip of a rotary file on resistance. Fractographic analysis was performed on the fractured files to further understand the mode of failure. Size F2 ProTaper Ultimate (PTU) and ProTaper Gold (PTG) files from Dentsply Sirona were rotated with either a 30° or …

    ubc Repository record for Combined torsional and cyclic fatigue resistance of rotary endodontic files (opens in a new tab) Download PDF for Combined torsional and cyclic fatigue resistance of rotary endodontic files (opens in a new tab)

  15. Torsion and Bending Properties of EdgeEndo Files

    … canal. This process involves using endodontic rotary files combined with chemical irrigants to remove pulpal remnants and infected dentin from the canal while eliminating pathogenic bacteria. It is essential to maintain proper canal anatomy while cleaning and shaping. The challenge for the …

    marquette Repository record for Torsion and Bending Properties of EdgeEndo Files (opens in a new tab)

  16. Assessment of Fracture Resistance of Maxillary First Molars after Root Canal Preparation Using Three Different Rotary Instruments (V-Taper, ProTaper, Vortex Blue): Finite Element Analysis

    … of endodontically treated teeth. As a result, rotary instrument manufacturers have developed files that have a minimal effect on original root canal anatomy. This study used Finite Element Analysis to investigate the dental biomechanical effect of rotary instrumentation during root canal …

    wvu Repository record for Assessment of Fracture Resistance of Maxillary First Molars after Root Canal Preparation Using Three Different Rotary Instruments (V-Taper, ProTaper, Vortex Blue): Finite Element Analysis (opens in a new tab)

  17. Comparing Cyclic Fatigue of the new GT® Series XTM Files to the Original ProFile® GT® Rotary Instruments

    … to fracture of the M-Wire GT® Series X(TM) rotary files compared to the original ProFile® GT® rotary files in a simulated curved canal. Eighty GT® Series X(TM) files of 25mm length were divided into eight groups of ten, one for each of the new GT® Series X(TM) files. Eighty original ProFile® …

    vcu Repository record for Comparing Cyclic Fatigue of the new GT® Series XTM Files to the Original ProFile® GT® Rotary Instruments (opens in a new tab)