Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"rotary files"”.

  1. Influence of Taper on the Flexibility of Nickel-Titanium Rotary Files

    … on the flexibility of various nickel-titanium files. Materials and Methods: The flexibility of stainless steel hand files and nickel-titanium rotary files of various tapers was measured. The sample size was 10 for each type, taper and size. The files were measured at 3, 5 and 7 mm from the tip …

    marquette Repository record for Influence of Taper on the Flexibility of Nickel-Titanium Rotary Files (opens in a new tab)

  2. Comparison of two methodologies for testing cyclic fatigue resistance of nickel-titanium rotary files

    Nickel titanium (NiTi) rotary files have become an important adjunct to endodontic treatment of the root canal system. However, despite the many advantages, Ni-Ti rotary files have a risk of unexpected fracture without any visible signs of previous permanent deformation. A wide range of …

    bu Repository record for Comparison of two methodologies for testing cyclic fatigue resistance of nickel-titanium rotary files (opens in a new tab)

  3. Apical Canal Transportation after Instrumentation with Two New Rotary Files; A comparative Study with Micro CT

    … canal anatomy, using TRUShape RTM 3D Conforming Files, and EdgeEvolve(TM) files.;Materials and Methods.;Thirty maxillary molars were mounted at the cemento-enamel junction in modified poly-propylene 50 ml centrifuge tubes using a radiolucent methyl methacrylate acrylic resin. All specimens were …

    wvu Repository record for Apical Canal Transportation after Instrumentation with Two New Rotary Files; A comparative Study with Micro CT (opens in a new tab)

  4. Performance and Preference of Rotary Files by Pre-Doctoral Dental Students at Marquette School of Dentistry

    … and procedural mishaps using different NiTi rotary systems in the hands of unexperienced pre-doctoral dental students; 2) to gain an understanding of which rotary file system students subjectively prefer. Methods: Second year dental students (n=94) enrolled in preclinical endodontics received …

    marquette Repository record for Performance and Preference of Rotary Files by Pre-Doctoral Dental Students at Marquette School of Dentistry (opens in a new tab)

  5. Cleaning Efficiency of Nickel Titanium GT and .04 Rotary Files when used in a Torque Controlled Rotary Handpiece

    … determined if the cleaning efficiency of NiTi rotary files in an endodontic electric handpiece using a no torque control setting was superior to that obtained when using the torque control feature. Fifty extracted human anterior teeth with straight canals were divided into two groups of 20 and …

    vcu Repository record for Cleaning Efficiency of Nickel Titanium GT and .04 Rotary Files when used in a Torque Controlled Rotary Handpiece (opens in a new tab)

  6. Efficacy of retreatment rotary files in removing obturation material with different sealer from the root canal system: a micro-computed tomography study

    Aim To evaluate efficacy of XP-3D and TRUShape rotary retreatment system for gutta-percha (GP) removal from root canals. Methodology Root canals of 40 extracted human single rooted teeth were prepared with ProTaper gold rotary system and obturated with hydraulic condensation technique with BC …

    bu Repository record for Efficacy of retreatment rotary files in removing obturation material with different sealer from the root canal system: a micro-computed tomography study (opens in a new tab)

  7. Effects of irrigation and agitation on apical vapor lock : an ex-vivo study

    … Vortex Blue 25/04 or ProTaper Gold F2 (25/08) rotary files. Presence of apical vapor lock was detected radiograph-ically using a contrast mixture (sodium hypochlorite & cesium chloride) as the irrigant. Manual dynamic agitation with 50 strokes of a well fitting gutta percha cone was performed …

    ubc Repository record for Effects of irrigation and agitation on apical vapor lock : an ex-vivo study (opens in a new tab) Download PDF for Effects of irrigation and agitation on apical vapor lock : an ex-vivo study (opens in a new tab)

  8. The Effect of Operational Speed on the Fracture of Nickel Titanium Rotary Instruments

    Numerous nickel titanium rotary file systems have been introduced in recent years. The recommended speed at which these files are to be operated varies widely between manufacturers. The purpose of this study was to test the number of rotations to fracture of NiTi rotary files when operated at …

    vcu Repository record for The Effect of Operational Speed on the Fracture of Nickel Titanium Rotary Instruments (opens in a new tab)

  9. Flexibility of Various Nickel-Titanium Rotary Endodontic Files

    Introduction: Nickel-titanium rotary files were originally developed to allow for greater flexibility when instrumenting root canals. The increased flexibility of nickel-titanium instruments allowed operators to negotiate canal curvatures with greater ease. File design is continually changing. …

    marquette Repository record for Flexibility of Various Nickel-Titanium Rotary Endodontic Files (opens in a new tab)

  10. SODIUM HYPOCHLORITE'S EFFECT ON NICKEL-TITANIUM ROTARY INSTRUMENTS AND ITS EFFECT ON RESISTANCE TO FRACTURE

    … in sodium hypochlorite on nickel-titanium rotary files and to determine whether resistance to fracture was influenced by the immersion time. One hundred K3™ and 100 ProFile® rotary files were either partially or totally immersed in 5.25% sodium hypochlorite for zero, one, five, thirty, or …

    vcu Repository record for SODIUM HYPOCHLORITE'S EFFECT ON NICKEL-TITANIUM ROTARY INSTRUMENTS AND ITS EFFECT ON RESISTANCE TO FRACTURE (opens in a new tab)

  11. Comparing Cyclic Fatigue of the new GT® Series XTM Files to the Original ProFile® GT® Rotary Instruments

    … to fracture of the M-Wire GT® Series X(TM) rotary files compared to the original ProFile® GT® rotary files in a simulated curved canal. Eighty GT® Series X(TM) files of 25mm length were divided into eight groups of ten, one for each of the new GT® Series X(TM) files. Eighty original ProFile® …

    vcu Repository record for Comparing Cyclic Fatigue of the new GT® Series XTM Files to the Original ProFile® GT® Rotary Instruments (opens in a new tab)

  12. A Comparative Study of Rotary Instrumentation of the Maxillary First Premolar Buccal Root Utilizing Cone Beam Computed Tomography

    … larger, 0.04 tapered, nickel titanium rotary files. Pre-instrumentation and post-instrumentation imaging was accomplished utilizing Cone Beam Computed Tomography. All data was analyzed using an ANOVA. Instrumentation resulted in a significant reduction in dentin-cementum wall thickness …

    vcu Repository record for A Comparative Study of Rotary Instrumentation of the Maxillary First Premolar Buccal Root Utilizing Cone Beam Computed Tomography (opens in a new tab)

  13. The Effect of Sodium Hypochlorite on Nickel Titanium Rotary Instruments and its Effect on Resistance to Fracture

    … in sodium hypochlorite on nickel titanium rotary files and determine whether resistance to fracture was influenced by the immersion time. 70 ISO size 25 0.04 taper nickel titanium K3 and Profile rotary instruments were immersed in 5.25% sodium hypochlorite for 1, 5, 15, 30, 60, and 120 …

    vcu Repository record for The Effect of Sodium Hypochlorite on Nickel Titanium Rotary Instruments and its Effect on Resistance to Fracture (opens in a new tab)

  14. Obturation with gutta percha of greater taper

    … instrumented with ProFile Series 29, 0.06 taper rotary files. Canals were obturated as follows: (Group 1) cold lateral condensation using an ISO size master gutta percha point; (Group 2) cold lateral condensation using a DiaPro 0.04 taper master gutta percha point; (Group 3) warm vertical hybrid …

    wvu Repository record for Obturation with gutta percha of greater taper (opens in a new tab)

  15. A comparison of rotary and reciprocating nickel titanium preparation in simulated root canals

    … simulated canals with ProTaper nickel titanium rotary files using an electric motor in both the classical ProTaper sequence of four files in a continually clockwise rotating action, and in a reciprocating clockwise and anticlockwise fashion using only one file from the ProTaper sequence- the F2. …

    birmingham Download PDF for A comparison of rotary and reciprocating nickel titanium preparation in simulated root canals (opens in a new tab)

  16. Apical Leakage of a New Root Canal Sealer

    … S1 and S2 Protaper Universal (DENTSPLY RTM) NiTi rotary files. Then the teeth were instrumented to a #30 .06 taper master apical file with Brasseler RTM Endosequence Niti rotary files in a crown down technique. Teeth were then divided into the groups: Group A- lateral condensation technique with …

    wvu Repository record for Apical Leakage of a New Root Canal Sealer (opens in a new tab)

  17. Effect of Autoclaving on Flexibility of Four Different Nickel Titanium Files

    Introduction: Nickel-titanium (NiTi) files, introduced over 2 decades ago, have the unique property of superelasticity, are more resistant to fracture and are more flexible than stainless steel files. Recent developments in NiTi include M wire and Controlled/Thermal Memory Technology resulting in …

    marquette Repository record for Effect of Autoclaving on Flexibility of Four Different Nickel Titanium Files (opens in a new tab)

  18. Evaluation of Obturation Extrusion of Guttacore with Varying Insertion Rates

    … were prepared with Waveone Gold nickel titanium rotary files to a size “primary” file. The prepared blocks were divided into three groups: group 1 was obturated using GuttaCore size primary obturator (analogous to the reciprocating file size) at a rate of 1 seconds; group 2 was obturated at a …

    uconn-diss Repository record for Evaluation of Obturation Extrusion of Guttacore with Varying Insertion Rates (opens in a new tab)

  19. Comparison of Epiphany® and AH-Plus® Root Canal Sealer Penetration of Dentinal Tubules: A SEM Study

    … to size 30, 0.06 taper using nickel-titanium rotary files and subjected to an identical irrigation protocol. Specimens were randomly divided into eight groups according to final irrigating solution (saline, 70%, 95%, or 100% ethanol) and obturation material (GP/AH-Plus® or Resilon/EpiphanyÒ …

    vcu Repository record for Comparison of Epiphany® and AH-Plus® Root Canal Sealer Penetration of Dentinal Tubules: A SEM Study (opens in a new tab)

  20. The Influence of Peri-Cervical Dentin Conservation on the Propagation of Cracks in Mandibular Molars

    … 1: Instrumented with using Protaper Gold (PTG) rotary files. Group 2: Instrumented with using TruNatomy. Each access was restored with composite at the level of the CEJ to the occlusal surface. The two teeth were digitized using a high-resolution micro–computed tomographic scan to create 3-D …

    marquette Repository record for The Influence of Peri-Cervical Dentin Conservation on the Propagation of Cracks in Mandibular Molars (opens in a new tab)

Page 1 of 2