Showing 1 to 20 of 30 for “"rotating biological contactor"”.

  1. Continuous Rotating Biological Contactor for Denitrification of Wastewater

    … a pilot plant study where a completely submerged rotating biological contactor was used for denitrification of domestic wastewater.</p> <p>The literature review emphasizes the existing knowledge on RBC operation and design fundamentals. A brief summary of the theory of denitrification has been …

    mcmaster Repository record for Continuous Rotating Biological Contactor for Denitrification of Wastewater (opens in a new tab)

  2. Temperature scale-up on rotating biological contactor nitrification system

    <p>The relationship between RBC scale-up factor (SUF) and wastewater temperature is successfully developed by using Dr. Wu's mathematical model as a basis and 114 sets of data from the operation of 8 full-scale and 5 pilot-scale RBC plants served for NH3-N removal. The SUF obtained from this study …

    njit Repository record for Temperature scale-up on rotating biological contactor nitrification system (opens in a new tab)

  3. Disc size scale-up in rotating biological contactor system

    <p>Disc size scale-up of prototype and small-scale RBC plants are successfully developed by applying the 114 data sets obtained from 12 RBC plants to the evaluation of percent sBOD remaining. These data analyses are performed by the least square method, therefore, the scale-up factors of the …

    njit Repository record for Disc size scale-up in rotating biological contactor system (opens in a new tab)

  4. Aerobic treatment of a CTMP wastewater using a rotating biological contactor

    … was undertaken to demonstrate the ability of a rotating biological contactor to remove organic matter from such a CTMP wastewater when operated at different flowrates and temperatures. An apparatus was constructed to allow for temperature control of the wastewater and the flexibility to change …

    ubc Repository record for Aerobic treatment of a CTMP wastewater using a rotating biological contactor (opens in a new tab) Download PDF for Aerobic treatment of a CTMP wastewater using a rotating biological contactor (opens in a new tab)

  5. Start-up and shock loading characteristics of a rotating biological contactor package plant

    A full-scale rotating biological contactor treatment system primarily used for treatment of wastes from single-family dwellings was studied at the Blacksburg-Virginia Tech wastewater treatment plant. Municipal primary clarifier effluent was pumped into the 600 gpd rated RBC unit at the rate of 480 …

    vt Repository record for Start-up and shock loading characteristics of a rotating biological contactor package plant (opens in a new tab)

  6. A STUDY OF THE MICROORGANISMS INHABITING ROTATING BIOLOGICAL CONTACTOR BIOFILMS DURING VARIOUS OPERATING CONDITIONS

    The microbial ecology of rotating biological contactors (RBC) is a combination of complex interrelationships among bacteria, protozoa, and metazoa and their perceived environment. Since very little information is available on the microorganisms inhabiting the biofilms, the major objective of this …

    unh-thes Repository record for A STUDY OF THE MICROORGANISMS INHABITING ROTATING BIOLOGICAL CONTACTOR BIOFILMS DURING VARIOUS OPERATING CONDITIONS (opens in a new tab)

  7. Treatment of trucking station wastewater by two-phase anaerobic digestion system and rotating biological contactor

    … two-phase anaerobic digestion system followed by rotating biological contactor. More than 90% of both COD and BOD was removed by the anaerobic digestion system having a retention time of 0.67 days and 4.03 days in the acid digester and the methane digester, respectively. The concentration of BOD …

    njit Repository record for Treatment of trucking station wastewater by two-phase anaerobic digestion system and rotating biological contactor (opens in a new tab)

  8. Microbial treatability of aqueous film forming foam (AFFF) with a chemostat and a rotating biological contactor.

    AFFF proved nontoxic to sewage-type microorganisms within the RBC. However, an organic load of 11.8 kg m('-3) d('-1) resulted in a decrease in dissolved oxygen, thus enriching for "bulking-type" organisms within the first two stages. No correlation between predominant microbial populations and AFFF …

    oklahoma-thes Repository record for Microbial treatability of aqueous film forming foam (AFFF) with a chemostat and a rotating biological contactor. (opens in a new tab)

  9. Sustainability Assessment of Coupling a Rotating Biological Contactor with an Anaerobic Baffled Reactor for Municipal Wastewater Treatment

    … times the impact of CO2. In this work, we test a rotating biological contactor (RBC), for its ability to oxidize methane, dissolved in a synthetic anaerobic effluent. We used laboratory data combined with engineering process models, life cycle assessment (LCA) and technoeconomic analysis (TEA), to …

    bucknell Repository record for Sustainability Assessment of Coupling a Rotating Biological Contactor with an Anaerobic Baffled Reactor for Municipal Wastewater Treatment (opens in a new tab)

  10. Mathematical Modeling for Nitrogen Removal via a Nitritation: Anaerobic Ammonium Oxidation-Coupled Biofilm in a Hollow Fiber Membrane Bioreactor and a Rotating Biological Contactor

    … anammox-coupled biofilm in a co-diffusion rotating biological contactor (RBC) were developed and implemented using AQUASIM. Four different start-up scenarios on the nitritation: anammox-coupled biofilm in an HFMBR were investigated. The supply of oxygen was simulated with the flow through …

    vt Repository record for Mathematical Modeling for Nitrogen Removal via a Nitritation: Anaerobic Ammonium Oxidation-Coupled Biofilm in a Hollow Fiber Membrane Bioreactor and a Rotating Biological Contactor (opens in a new tab)

  11. Modeling effects of U-tube aeration in recirculating aquaculture systems

    … of RAS component design, water quality, and biological processes on oxygen transfer requirements. A computer model was developed to simulate multi-component gas transfer and biological respiration in a pilot scale recirculating aquaculture system employing an u-tube aerator. Gas transfer …

    vt Repository record for Modeling effects of U-tube aeration in recirculating aquaculture systems (opens in a new tab)

  12. Influence of heavy metal concentration on rotating biological contrator performance

    … at various concentrations were investigated in a Rotating Biological Contactor (RBC) system. The experimental data indicated that the degree of heavy metal toxicity in the biological system mainly depended on the ratio of inflow heavy metal concentration to organic loading. The optimal ratio of …

    njit Repository record for Influence of heavy metal concentration on rotating biological contrator performance (opens in a new tab)

  13. Biological Fluidized Bed Denitrification of Wastewater

    … relationship (4°-27° C), adequately described biological denitrification of municipal wastewater in a pilot scale fluidized bed reactor. Biofilm support media (activated carbon or sand) and hydraulic flux (0.25-1.7 m^3/m^2·min) were not found to be significant factors in controlling …

    mcmaster Repository record for Biological Fluidized Bed Denitrification of Wastewater (opens in a new tab)

  14. RBC treatment of a municipal landfill leachate : a pilot scale evaluation

    … low strength municipal landfill leachate with a Rotating Biological Contactor (RBC), at pilot scale (0.9 m dia.). The leachate generally had COD and NH₃-N concentrations of less than 1000 mg/L and 50 mg/L respectively. A high treatment efficiency for both carbon removal and nitrification was …

    ubc Repository record for RBC treatment of a municipal landfill leachate : a pilot scale evaluation (opens in a new tab) Download PDF for RBC treatment of a municipal landfill leachate : a pilot scale evaluation (opens in a new tab)

  15. An Evaluation of Unstratified Granular Media Filtration of Effluent from a Rotating Biological Contractor

    … concerning the filtration of effluent from a rotating biological contactor (RBC). The purpose of this investigation, and subsequent thesis, was to evaluate the filterability of RBC effluent with regards to effluent quality and headless development. Another point of investigation was the …

    marquette Repository record for An Evaluation of Unstratified Granular Media Filtration of Effluent from a Rotating Biological Contractor (opens in a new tab)

  16. Performance of Rotating Biological Contactors under Transient Loading Conditions

    … the dynamic response of a 0. 5 metre pilot scale rotating biological contactor when operated under transient influent conditions. Experimental data are presented for two modes of operation: carbon oxidation and carbon oxidation plus nitrification. During the carbon oxidation experimental runs, a …

    mcmaster Repository record for Performance of Rotating Biological Contactors under Transient Loading Conditions (opens in a new tab)